Andrew I. Sheinis
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew I. Sheinis has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Brian M. Sutin
Jet Propulsion Lab. (United States)
3 shared publications - Harland W. Epps
UCO/Lick Observatory (United States)
3 shared publications - B. C. Bigelow2 shared publications
Jerry E. Nelson
UCO/Lick Observatory (United States)
2 shared publications- Joseph S. Miller
UCO/Lick Observatory, University of California at Santa Cruz, Santa Cruz, CA 95064
2 shared publications M. V. Radovan
2 shared publications
Latest Publications
- 1 August 2002
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 114 (798) , 851-865
ESI, a New Keck Observatory Echellette Spectrograph and Imager
The Echellette Spectrograph and Imager (ESI) is a multipurpose instrument which has been delivered by the Instrument Development Laboratory of Lick Observatory for use at the Cassegrain focus of the Keck II telescope. ESI saw first light on August 29, 1999. ESI is a multi-mode instrument that enables the observer to seamlessly switch between three modes during an observation. The three modes of ESI are: An R=13,000-echellette mode; Low-dispersion prismatic mode; Direct imaging mode. ESI contains a unique flexure compensation system which reduces the small instrument flexure to negligible proportions. Long-exposure images on the sky show FWHM spot diameters of 34 microns (0.34") averaged over the entire field of view. These are the best non-AO images taken in the visible at Keck Observatory to date. Maximum efficiencies are measured to be 28% for the echellette mode and greater than 41% for low-dispersion prismatic mode including atmospheric, telescope and detector losses. In this paper we describe the instrument and its development. We also discuss the performance-testing and some observational results.Comment: 10 pages, 14 figures, 8tables, accepted for publication in PASP, 15 April 200
- 1 August 2002
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 114 (798) , 851-865
ESI, a New Keck Observatory Echellette Spectrograph and Imager
The Echellette Spectrograph and Imager (ESI) is a multipurpose instrument which has been delivered by the Instrument Development Laboratory of Lick Observatory for use at the Cassegrain focus of the Keck II telescope. ESI saw first light on August 29, 1999. ESI is a multi-mode instrument that enables the observer to seamlessly switch between three modes during an observation. The three modes of ESI are: An R=13,000-echellette mode; Low-dispersion prismatic mode; Direct imaging mode. ESI contains a unique flexure compensation system which reduces the small instrument flexure to negligible proportions. Long-exposure images on the sky show FWHM spot diameters of 34 microns (0.34") averaged over the entire field of view. These are the best non-AO images taken in the visible at Keck Observatory to date. Maximum efficiencies are measured to be 28% for the echellette mode and greater than 41% for low-dispersion prismatic mode including atmospheric, telescope and detector losses. In this paper we describe the instrument and its development. We also discuss the performance-testing and some observational results.Comment: 10 pages, 14 figures, 8tables, accepted for publication in PASP, 15 April 200
- Open Access
ESI, a new Keck Observatory echellette spectrograph and imager
The Echellette Spectrograph and Imager (ESI) is a multipurpose instrument which has been delivered by the Instrument Development Laboratory of Lick Observatory for use at the Cassegrain focus of the Keck II telescope. ESI saw first light on August 29, 1999. ESI is a multi-mode instrument that enables the observer to seamlessly switch between three modes during an observation. The three modes of ESI are: An R=13,000-echellette mode; Low-dispersion prismatic mode; Direct imaging mode. ESI contains a unique flexure compensation system which reduces the small instrument flexure to negligible proportions. Long-exposure images on the sky show FWHM spot diameters of 34 microns (0.34") averaged over the entire field of view. These are the best non-AO images taken in the visible at Keck Observatory to date. Maximum efficiencies are measured to be 28% for the echellette mode and greater than 41% for low-dispersion prismatic mode including atmospheric, telescope and detector losses. In this paper we describe the instrument and its development. We also discuss the performance-testing and some observational results.
Open AccessESI, a new Keck Observatory echellette spectrograph and imager
The Echellette Spectrograph and Imager (ESI) is a multipurpose instrument which has been delivered by the Instrument Development Laboratory of Lick Observatory for use at the Cassegrain focus of the Keck II telescope. ESI saw first light on August 29, 1999. ESI is a multi-mode instrument that enables the observer to seamlessly switch between three modes during an observation. The three modes of ESI are: An R=13,000-echellette mode; Low-dispersion prismatic mode; Direct imaging mode. ESI contains a unique flexure compensation system which reduces the small instrument flexure to negligible proportions. Long-exposure images on the sky show FWHM spot diameters of 34 microns (0.34") averaged over the entire field of view. These are the best non-AO images taken in the visible at Keck Observatory to date. Maximum efficiencies are measured to be 28% for the echellette mode and greater than 41% for low-dispersion prismatic mode including atmospheric, telescope and detector losses. In this paper we describe the instrument and its development. We also discuss the performance-testing and some observational results.
- Open Access
Spatially resolved spectroscopy of emission-line gas in QSO Host galaxies
We present off-nuclear spectra of 3 radio loud QSO's, 3C249.1, 3C273 and 3C323.1., taken with the echellette spectrograph and imager (ESI) at Keck observatory. From these spectra we have extracted the spatial profile along the slit of the [OIII], $\lambda= \textsf{5007}$ line. Fitted Gaussian distributions to each of these profiles show emission-line gas out to several tens of kiloparsecs from the galaxy nucleus. Most observations show several gas components at distinct velocities and velocity dispersions, much of which is above the escape velocity for any resonable mass galaxy. In addition, we show slitless spectroscopy images for one other object, 3C48. From the slitless spectroscopy images we can extract 2-dimensional spatial as well as velocity information on the emission line gas.Open AccessSpatially resolved spectroscopy of emission-line gas in QSO Host galaxies
We present off-nuclear spectra of 3 radio loud QSO's, 3C249.1, 3C273 and 3C323.1., taken with the echellette spectrograph and imager (ESI) at Keck observatory. From these spectra we have extracted the spatial profile along the slit of the [OIII], $\lambda= \textsf{5007}$ line. Fitted Gaussian distributions to each of these profiles show emission-line gas out to several tens of kiloparsecs from the galaxy nucleus. Most observations show several gas components at distinct velocities and velocity dispersions, much of which is above the escape velocity for any resonable mass galaxy. In addition, we show slitless spectroscopy images for one other object, 3C48. From the slitless spectroscopy images we can extract 2-dimensional spatial as well as velocity information on the emission line gas. - 1 January 2001
- Published by Springer Nature
- p. 141-144
Spatially Resolved Spectroscopy of Emission-Line Gas in QSO Host Galaxies
- 1 January 2001
- Published by Springer Nature
- p. 141-144
Spatially Resolved Spectroscopy of Emission-Line Gas in QSO Host Galaxies
- 16 June 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4009, 262-274
Active flexure compensation software for the echellette spectrograph and imager on Keck II
All Cassegrain spectrographs suffer from gravitationally- induced flexure to some degree. While such flexure can be minimized via careful attention to mechanical design and fabrication, further performance improvements can be achieved if the spectrograph has been designed to minimize hysteresis and has active compensation for any residual flexure. The Echellette Spectrograph and Imager (ESI), built at UCO/Lick Observatory for use at Cassegrain focus on Keck II, compensates for such residual flexure via its collimator mirror. The collimator is driven by three actuators that provide control of collimator focus, tip, and tilt. The ESI control software utilizes a mathematical model of gravitationally-induced flexure to periodically compute and apply flexure corrections by commanding the corresponding tip and tilt motions to the collimator. In addition, the ESI control software provides an optional, manual, closed-loop method for adjusting the collimator position to compensate for any non-repeatable errors. Such errors may result from mechanical hysteresis or from thermally-induced structural deformations of the instrument and are thus not accounted for by the gravitational flexure model. This method relies on measuring the centroid position of fiducial spots within each echellete image. The collimator is adjusted so that the positions of these spots match those in a reference image. These spots are produced by a small round hole in the slit mask located near one end of the slit. We discuss the design and calibration of this flexure compensation system and report on its performance ont he telescope.
- 16 June 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4009, 262-274
Active flexure compensation software for the echellette spectrograph and imager on Keck II
All Cassegrain spectrographs suffer from gravitationally- induced flexure to some degree. While such flexure can be minimized via careful attention to mechanical design and fabrication, further performance improvements can be achieved if the spectrograph has been designed to minimize hysteresis and has active compensation for any residual flexure. The Echellette Spectrograph and Imager (ESI), built at UCO/Lick Observatory for use at Cassegrain focus on Keck II, compensates for such residual flexure via its collimator mirror. The collimator is driven by three actuators that provide control of collimator focus, tip, and tilt. The ESI control software utilizes a mathematical model of gravitationally-induced flexure to periodically compute and apply flexure corrections by commanding the corresponding tip and tilt motions to the collimator. In addition, the ESI control software provides an optional, manual, closed-loop method for adjusting the collimator position to compensate for any non-repeatable errors. Such errors may result from mechanical hysteresis or from thermally-induced structural deformations of the instrument and are thus not accounted for by the gravitational flexure model. This method relies on measuring the centroid position of fiducial spots within each echellete image. The collimator is adjusted so that the positions of these spots match those in a reference image. These spots are produced by a small round hole in the slit mask located near one end of the slit. We discuss the design and calibration of this flexure compensation system and report on its performance ont he telescope.
- 28 September 1999
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3786, 413-427
Assembly and testing of the ESI camera
The Echellette Spectrograph and Imager (ESI), currently being delivered for use at the Cassegrain focus of the Keck II telescope employs an all-spherical, 308 mm focal length f/1.07 Epps camera. The camera consists of 10 lens elements in 5 groups: an oil-coupled doublet; a singlet, an oil- coupled triplet; a grease-coupled triplet; and a field flattener, which also serves as the vacuum-dewar window. A sensitivity analysis suggested that mechanical manufacturing tolerances of order +/- 25 microns were appropriate. In this paper we discuss the sensitivity analysis, the assembly and the testing of this camera.
- 28 September 1999
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3786, 413-427
Assembly and testing of the ESI camera
The Echellette Spectrograph and Imager (ESI), currently being delivered for use at the Cassegrain focus of the Keck II telescope employs an all-spherical, 308 mm focal length f/1.07 Epps camera. The camera consists of 10 lens elements in 5 groups: an oil-coupled doublet; a singlet, an oil- coupled triplet; a grease-coupled triplet; and a field flattener, which also serves as the vacuum-dewar window. A sensitivity analysis suggested that mechanical manufacturing tolerances of order +/- 25 microns were appropriate. In this paper we discuss the sensitivity analysis, the assembly and the testing of this camera.
- 28 September 1999
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3786, 350-362
Kinematic translation mechanism for moderate-sized optics
The Echellete Spectrograph and Imager (ESI), currently being completed for use at the cassegrain focus of the Keck II telescope, employs two moderate size translating fold mirrors. These mirrors are used to shift between the three instrument modes; medium resolution echellete mode; low resolution prismatic mode; and imaging mode. In order to maintain the optical stability and calibration of these three modes the mirrors must be removed and repeatably located to within 1.3 arcsecs of tip and tilt. In addition, the mirrors must maintain a fixed orientation relative to the telescope axis under a variety of gravity and thermal loads. In this paper we describe a novel concept for moving and locating these mirrors. Analytical analysis of the mounts is presented. Optical and mechanical testing is described.
- 28 September 1999
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3786, 350-362
Kinematic translation mechanism for moderate-sized optics
The Echellete Spectrograph and Imager (ESI), currently being completed for use at the cassegrain focus of the Keck II telescope, employs two moderate size translating fold mirrors. These mirrors are used to shift between the three instrument modes; medium resolution echellete mode; low resolution prismatic mode; and imaging mode. In order to maintain the optical stability and calibration of these three modes the mirrors must be removed and repeatably located to within 1.3 arcsecs of tip and tilt. In addition, the mirrors must maintain a fixed orientation relative to the telescope axis under a variety of gravity and thermal loads. In this paper we describe a novel concept for moving and locating these mirrors. Analytical analysis of the mounts is presented. Optical and mechanical testing is described.