DBDieter H. Boehm

Dieter H. Boehm

*This is an algorithmically generated author record based on publicly available information.

Dieter H. Boehm has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Die EKG-getriggerte 4-Zeilen-Spiral-CT des Herzens in der präoperativen Bildgebung vor minimalinvasiver koronarer Bypass-Operation

    by P. G. C. Begemann, M. Arnold, C. Detter, D. H. Boehm, H. Ittrich, A. Koops, H. Reichenspurner, G. Adam, C. Weber

    Ziel: Evaluiert wurde die EKG-getriggerte 4-Zeilen-Spiral-CT (MSCT) des Herzens als präoperative Diagnostik bei Patienten mit geplanter minimalinvasiver koronarer Bypass-OP über eine links anteriore Minithorakotomie. Material und Methoden: Retrospektiv wurden 25 konsekutive Patienten ausgewertet, die eine MSCT des Herzens nativ und nach Kontrastmittelgabe erhielten. Beurteilt wurden das Ausmaß der Verkalkungen des Ramus interventricularis anterior (RIVA), die Abstände zwischen RIVA und linker Arteria mammaria interna (LIMA), das Vorhandensein von Muskelbrücken, die Lage des RIVA im epikardialen Fettgewebe, der Verlauf der LIMA und das Vorhandensein ventraler pleuraler Schwielen. Die Ergebnisse wurden mit den intraoperativen Befunden korreliert. Ergebnisse: Alle MSCT waren auswertbar und hatten in 20/25 Fällen Einfluss auf die Wahl des OP-Verfahrens (elf MIDCAB, sieben OPCAB mit Ministernotomie, fünf OPCAB mit vollständiger Sternotomie, zwei konventionelle Operationen). Der RIVA-LIMA-Abstand betrug 0,9 bis 4,5 cm. 3/25 korrelierten Patienten hatten Verkalkungen des mittleren RIVA, zehn Patienten hatten keine Verkalkungen. Bei sieben Patienten zeigte sich intraoperativ eine Gefäßsklerose, ohne dass Verkalkungen in der MSCT nachweisbar waren. Bei weiteren fünf Patienten ließen sich in der MSCT einzelne Kalkplaques des mittleren RIVA nachweisen, die Anastomose wurde jedoch zwischen den Plaques angelegt, vier Gefäßabschnitte waren dabei fibrosiert, einer normal. In der MSCT und intraoperativ wurden keine Muskelbrücken nachgewiesen. Ein im epikardialen Fett eingebetteter RIVA wurde bei 9/25 Patienten nachgewiesen und bei 15 ausgeschlossen. Bei einem Patienten schien der RIVA in der MSCT oberflächlich, war jedoch intraoperativ mit Fett bedeckt. Die LIMA stellte sich bei allen Patienten regelrecht dar, pleurale Schwielen fanden sich nicht. Schlussfolgerung: Die 4-Zeilen-Spiral-CT liefert zusätzlich zur Koronarangiographie wichtige Informationen in der präoperativen Evaluation vor minimalinvasiver koronarer Bypass-OP. Purpose: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. Material and Methods: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4x2.5 mm) and contrast-enhanced examination (140 - 170 ml, 300 mg Iodine/ml, collimation 4x1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), course of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. Results: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and at surgery. Bridging of epicardial fat was shown by MDCT and at surgery in 9/25 patients and was excluded in 15 patients. In 1 patient, the LAD seemed to run superficially in MDCT, but was covered with fat as seen during surgery. The course of the LIMA was inconspicuous in all cases, no pleural fibrosis was found. Conclusions: The 4-row MDCT has proven to be adequate in addition to coronary angiography for preoperative evaluation in patients scheduled for MIDCAB and provides the surgeon with relevant information for the selection of the operative approach.


  • Clinical Use of a Computer-enhanced Surgical Robotic System for Endoscopic Coronary Artery Bypass Grafting on the Beating Heart1

    by D. H. Boehm, H. Reichenspurner, C. Detter, M. Arnold, H. Gulbins, B. Meiser, B. Reichart

    The aim of the study was to perform endoscopic coronary artery bypass grafting on the beating heart using a surgical robotic system. In the study, the surgical system ZEUSTM was used in combination with 3D visualization for endoscopic coronary artery bypass grafting in 25 patients. In a total of 10 cases, the coronary artery anastomosis was done on the beating heart using endoscopic stabilizers without cardiopulmonary bypass. In all cases, total OR time ranged from 4.0 to 8.0 hours (median 5.5 h); the times for endoscopic coronary artery anastomoses ranged from 14 to 50 minutes (median 25 minutes) with no difference between arrested-heart or beating-heart procedures. All patients had an uneventful angiographic control result. An endoscopic coronary artery anastomosis is possible on the arrested as well as on the beating heart. 1 Presented at the 3rd Joint Meeting of the German, the Austrian and the Swiss Societies for Thoracic and Cardiovascular Surgery, February 9-12, 2000, Luzern


  • Early experience with robotic technology for coronary artery surgery

    by Dieter H Boehm, Hermann Reichenspurner, Helmut Gulbins, Christian Detter, Bruno Meiser, Paolo Brenner, Helmut Habazettl, Bruno Reichart


    • 1 January 1999
      • Vol. 2  (1) , 54-9

    Continuous transesophageal echocardiographic (TEE) monitoring during port-access cardiac surgery.

    by C J Schulze, S M Wildhirt, D H Boehm, C Weigand, A Kornberg, H Reichenspurner, B Reichart

    Since the introduction of the closed-chest minimally invasive heart surgery using the Port-Access system a variety of monitoring techniques including fluoroscopy, transesophageal echocardiography (TEE) and invasive pressure measurements have been described. We investigated whether or not single TEE is feasible for perioperative monitoring of the placement, localization and proper function of the endovascular cardiopulmonary bypass (CPB) devices. Fifty-one patients (35 mitral valve repair or replacement [MVR], 8 coronary artery bypass grafting [CABG], 5 atrial septal defects [ASD] and 3 left atrial myxoma) were subjected to Port-Access surgery (PAS). Intraoperative Omniplane-TEE (2D- and color-flow Doppler techniques) was used as the leading monitoring device for correct positioning of the endopulmonary vent catheter and the venous cannula, and for the visualization of the guide wire and the endoaortic occlusion catheter (Endoclamp). After balloon inflation, its proper positioning and function during endo-aortic occlusion, sufficient delivery of cardioplegia into the coronary ostia, absence of leakage flow and adequate venting were controlled. Left and right radial artery catheters as well as aortic root pressure measurements served as controls. Additional fluoroscopy was used as standby device. In 46 patients (90.1%) sufficient perioperative monitoring was provided by single TEE. In five cases additional intermittent fluoroscopy was necessary for correct positioning of the guide wire (CABG) and the Endoclamp (three MVR and one ASD). Dislocation of the Endoclamp into the left ventricle was observed once but was successfully corrected by TEE guidance. Weaning from CPB and de-airing were easily guided with TEE. We did not observe balloon-mediated aortic injury or aortic valve dysfunction, and myocardial recovery from CPB was uneventful. All cases of MVRs showed sufficient results (68% without evidence of regurgitation, 32% showed residual mitral valve incompetence of less than grade II). Neither perivalvular leakage (MV-replacement) nor shunt- (residual ASD) flow were detectable. We recommend single TEE as a safe and effective on-line imaging device for monitoring the endovascular CPB system during PAS. Fluoroscopy with its potential risk for the patients and the staff due to x-ray exposure should only be used in the presence of peripheral vascular disease or when echocardiographic imaging is insufficient.


    • 1 January 1999
      • Vol. 2  (3) , 222-5

    Contrast-enhanced magnetic resonance angiography for control of minimally invasive coronary artery bypass conduits (MIDCAB/OPCAB).

    by D H Boehm, B J Wintersperger, H Reichenspurner, H Gulbins, C Detter, F Kur, B Meiser, B Reichart

    The purpose of this study was to delineate the course and determine the patency of venous and arterial conduits in the early postoperative period following minimally invasive bypass grafting. A less invasive magnetic resonance angiogram was evaluated as alternative to standard contrast angiography and cardiac catheterization. Twelve patients (8 males and 4 females) with a mean age of 65.3 (+/- 7.4 ) years were evaluated four to seven days following minimally invasive direct coronary artery bypass surgery (MIDCAB) or off-pump multivessel revascularization with the Octopus stabilizer on the beating heart. Altogether 17 coronary bypass grafts were investigated: 12 left-sided mammary artery grafts to the LAD and five aortocoronary venous bypass grafts. The examination was performed with a 1.5 Tesla Magnetom Vision (Siemens AG, Erlangen) with phased array coil technology. Data acquisition was done with an ultrafast 3D gradient-echosequence in single breathhold and sagittal and coronal views. Contrast enhancement of the vessels was performed with automatic intravenous bolus injection of Gadolinium-DTPA after determination of the individual contrast transit time. Traditional contrast angiography was obtained in all patients during the same time period as a comparison to assess the sensitivity and specificity of the magnetic resonance imaging. All five venous grafts and 11 of the 12 IMA grafts were detected and shown to be patent with the MRA technique. Contrast angiography demonstrated complete patency for all 17 bypass grafts with adequate anastomoses and no evidence of stenosis. The calculated sensitivity for the visualization with MRA was therefore 92% for IMA grafts and 100% for venous grafts. The contrast-enhanced ultrafast MRA in single breathhold technique is a reliable, noninvasive method for visualization and determination of the patency of arterial and venous coronary grafts.

    • 1 January 1999
      • Vol. 2  (4) , 318

    3D-visualization improves the dry-lab coronary anastomoses using the Zeus robotic system.

    by H Gulbins, D H Boehm, H Reichenspurner, M Arnold, R Ellgass, B Reichart

    Robotic surgical instruments enable quick and precise movements and may allow complete endoscopic coronary artery bypass grafting. However, cardiac surgeons will have to become familiar with this technology and endoscopic viewing. We present our training program with special focus on 2D- and 3D-visualization. A thoracic skeleton, covered with a neoprene suit, served as model for the chest wall. Either a glove, fixed on a metal plate, or a pig heart were placed inside for training. On the glove, a suture line consisting of two lines of 16 points each, with a distance of 2 mm between each point, was stamped. On the pig heart, the LAD was prepared and incised; subsequently an anastomosis was done using the dissected right coronary artery as a graft. The time required was measured for both models. For suturing, the Zeus System (Computer Motion, Goleta, CA) was used and the third robotic arm positioned the endoscopic camera. The scopes were connected to a 3D-camera and the picture was displayed on a headset with two integrated monitors. Visualization was set to either 2D or 3D. Three surgeons were involved in the study. Each one did at least 12 anastomoses on 2D and 3D. The three surgeons involved showed a clear and rapid learning curve. The times required for the suture line decreased from 12.5 +/- 1.6 to 8.5 +/- 0.5 minutes with 2D and from 11.9 +/- 5.4 to 7.8 +/- 0.5 minutes for 3D respectively. This decrease did reach statistical significance (p = 0.03). In the pig heart model, the anastomosis times decreased from 33.2 +/- 8.4 to 15.7 +/- 0.3 minutes with 3D-visualization, and from 36.2 +/- 2.2 to 29.5 +/- 3.3 minutes with 2D. The decrease in anastomosis time did again reach significance (p = 0.025). At the end of the study, the times achieved with 2D-visualization were significantly longer than those with 3D (p = 0.01). A surgical training program is mandatory to become familiar with these new technologies. Both models showed learning curves over an acceptable time course. 3D-visualization facilitated quick and precise movements, thus resulting in shorter anastomosis times.


    • 1 January 1998
      • Vol. 1  (2) , 104-6

    3D-video- and robot-assisted minimally invasive ASD closure using the Port-Access techniques.

    by H Reichenspurner, D H Boehm, A Welz, C Schulze, B Zwissler, B Reichart

    Video-assisted minimally invasive surgical methods with endovascular-based femoral cardiopulmonary bypass (CPB) and balloon occlusion of the aorta (Port-Access technique) were used to close an ostium-secundum atrial septal defect (ASD) in 7 patients. Minor modifications were made to the system to provide drainage of the superior vena cava. The surgery was performed through a small (3.5-5cm) right anterolateral thoracotomy with 3D video and robotic arm assistance. The operative procedures were completely uneventful and the patients were discharged four days postoperatively in good condition and with excellent cosmesis. Using the modifications described, the Port-Access surgical method can be recommended for minimally invasive closure of an ASD.


    • 1 January 1998
      • Vol. 1  (2) , 111-5

    Preoperative 3D-reconstructions of ultrafast-CT images for the planning of minimally invasive direct coronary artery bypass operation (MIDCAB).

    by H Gulbins, H Reichenspurner, C Becker, D H Boehm, A Knez, C Schmitz, R Bruening, R Haberl, B Reichart

    The direct left internal mammary artery (LIMA) bypass to the left anterior descending (LAD) without the use of extracorporal circulation through a small anterolateral thoracotomy has become established among the minimally invasive techniques in cardiac surgery. Technical difficulties may occur in patients with an enlarged left ventricle and subsequent lateral positioning of the LAD, a small LAD, or a small LIMA. We used electron beam tomography (EBT) for preoperative visualization of the topographical structures to seek out patients with potential technical difficulties. Eighteen patients, mean age 62 +/- 13 years, were entered in this study; in all cases the indication for revascularization was a significant stenosis of the LAD. Preoperatively an ECG-triggered EBT was performed. Following the image acquisition, a three-dimensional reconstruction of the data was performed. The LIMA, LAD, first diagonal branch, and chest wall were stained different colors for better visualization. Surgery was performed using a left anterolateral mini-thoracotomy and through this access, the LIMA was dissected and anastomosed using a stabilizer without the use of extracorporal circulation. In all but one of the 18 patients who had a preoperative EBT, the minimally invasive direct coronary artery bypass (MIDCAB) procedure was successfully performed using an anterolateral mini-thoracotomy. Based on the results of the EBT, the 5 centimeter incision was done parasternally in six patients, and more laterally (2-4 cm parasternally) in the other eleven cases. In 13 patients the access penetrated the fourth intercostal space; in four cases the fifth intercostal space was used. In one patient EBT revealed a very laterally positioned and diffusely arteriosclerotic LAD so the patient was operated using a median sternotomy, but without the use of extracorporal circulation. In all 18 patients the preoperatively acquired information of the anatomical topography was confirmed intraoperatively. One case without a preoperative EBT had to be converted to a conventional procedure due to a small, intramyocardial LAD and a very small LIMA. Postoperative angiography revealed patent LIMA grafts and uneventful anastomoses. For minimally invasive direct coronary artery bypass (MIDCAB) the topography of the LIMA, LAD and intercostal spaces is of major importance. Using the ECG-triggered EBT with subsequent three-dimensional reconstruction these relationships can be visualized. This enables an individual planning of the operation and a minimalization of the skin incision.


    • 1 April 1990
      • Vol. 22  (2) , 545-6

    Adenosine and its role in cardioplegia: effects on postischemic recovery in the baboon.

    by D H Boehm, P A Human, H Reichenspurner, U Von Oppell, P Owen, L H Opie, B Reichart