Jens Dominik Agneskirchner
Research Subjects
Jens Dominik Agneskirchner has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
P. Lobenhoffer
Diakoniekrankenhaus Henriettenstiftung Hannover
11 shared publications- Christof Hurschler
Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
4 shared publications H. Hosseini
Diakoniekrankenhaus Henriettenstiftung Hannover
2 shared publicationsM. Tröger
Diakoniekrankenhaus Henriettenstiftung Hannover
2 shared publicationsPhilipp Lobenhoffer
Department of Trauma and Reconstructive Surgery Henriettenstiftung Hannover Hannover Germany
2 shared publicationsA. B. Imhoff
Technical University of Munich
1 shared publication
Latest Publications
- 23 January 2009
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 11 (S2) , 140-145
Reconstruction of the posterior cruciate ligament
- 23 January 2009
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 11 (S2) , 140-145
Reconstruction of the posterior cruciate ligament
- 1 August 2007
- Published by Wiley in Arthroscopy
- Vol. 23 (8) , 852-861
The Effects of Valgus Medial Opening Wedge High Tibial Osteotomy on Articular Cartilage Pressure of the Knee: A Biomechanical Study
Purpose: The objective of this study was to quantify the effect of different loading axes and of a valgus opening wedge high tibial osteotomy (HTO) on tibiofemoral cartilage pressure. Methods: Six human knee specimens were tested with a load of 1000N in extension in a materials testing machine using a specially designed fixture. Pressure in the medial and lateral joint compartment was recorded using pressure‐sensitive films. Different loading alignments (varus, straight, and valgus) were simulated. A medial opening wedge HTO was performed adjusting the loading axis to slight valgus. The first measurement was performed with intact medial collateral ligament (MCL). Then the MCL was dissected gradually and the cartilage pressure again analyzed. Results: There was a significant correlation of the load distribution with the position of the loading axis. The medial compartment was predominantly loaded in the varus setting. The more lateral the loading line intersected the knee, the more pressure was redistributed laterally. The opening wedge HTO without the MCL release resulted in a significant increase of the pressure medially ( P = .002). Only after a complete release of the MCL was a significant decrease of pressure medially observed after opening wedge HTO ( P = .003). Conclusions: The position of the loading axis in the frontal plane has a strong effect on the tibiofemoral cartilage pressure distribution of the knee. The medial compartment is predominantly loaded in a varus knee; a neutral mechanical axis slightly loads the lateral more than the medial compartment. In valgus alignment, the main load runs through the lateral compartment. Clinical Relevance: A medial opening wedge HTO maintains high medial compartment pressure despite the fact that the loading axis has been shifted into valgus. Only after complete release of the distal fibers of the MCL does the opening wedge HTO produce a decompression of the medial joint compartment.
- 1 August 2007
- Published by Wiley in Arthroscopy
- Vol. 23 (8) , 852-861
The Effects of Valgus Medial Opening Wedge High Tibial Osteotomy on Articular Cartilage Pressure of the Knee: A Biomechanical Study
Purpose: The objective of this study was to quantify the effect of different loading axes and of a valgus opening wedge high tibial osteotomy (HTO) on tibiofemoral cartilage pressure. Methods: Six human knee specimens were tested with a load of 1000N in extension in a materials testing machine using a specially designed fixture. Pressure in the medial and lateral joint compartment was recorded using pressure‐sensitive films. Different loading alignments (varus, straight, and valgus) were simulated. A medial opening wedge HTO was performed adjusting the loading axis to slight valgus. The first measurement was performed with intact medial collateral ligament (MCL). Then the MCL was dissected gradually and the cartilage pressure again analyzed. Results: There was a significant correlation of the load distribution with the position of the loading axis. The medial compartment was predominantly loaded in the varus setting. The more lateral the loading line intersected the knee, the more pressure was redistributed laterally. The opening wedge HTO without the MCL release resulted in a significant increase of the pressure medially ( P = .002). Only after a complete release of the MCL was a significant decrease of pressure medially observed after opening wedge HTO ( P = .003). Conclusions: The position of the loading axis in the frontal plane has a strong effect on the tibiofemoral cartilage pressure distribution of the knee. The medial compartment is predominantly loaded in a varus knee; a neutral mechanical axis slightly loads the lateral more than the medial compartment. In valgus alignment, the main load runs through the lateral compartment. Clinical Relevance: A medial opening wedge HTO maintains high medial compartment pressure despite the fact that the loading axis has been shifted into valgus. Only after complete release of the distal fibers of the MCL does the opening wedge HTO produce a decompression of the medial joint compartment.
- 1 February 2007
- Published by Springer Nature in Arthroskopie
- Vol. 20 (1) , 22-32
Arthroskopische Knotentechnik bei der Rotatorenmanschettenrekonstruktion
- 1 February 2007
- Published by Springer Nature in Arthroskopie
- Vol. 20 (1) , 22-32
Arthroskopische Knotentechnik bei der Rotatorenmanschettenrekonstruktion
- 5 September 2006
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (10) , 1035-1036
Reply to the letter by O. Cebesoy et al. on our publication “Primary stability of four different implants for opening wedge high tibial osteotomy”
- 5 September 2006
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (10) , 1035-1036
Reply to the letter by O. Cebesoy et al. on our publication “Primary stability of four different implants for opening wedge high tibial osteotomy”
- 1 May 2006
- Published by Springer Nature in Arthroskopie
- Vol. 19 (2) , 157-171
Komplikationen bei rekonstruktiven arthroskopischen Schulteroperationen
- 1 May 2006
- Published by Springer Nature in Arthroskopie
- Vol. 19 (2) , 157-171
Komplikationen bei rekonstruktiven arthroskopischen Schulteroperationen
- 12 November 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (3) , 291-300
Primary stability of four different implants for opening wedge high tibial osteotomy
Since a significant number of implant failures have been reported in association with the procedure of open wedge valgus high tibial osteotomy, the initial biomechanical stability of different fixation devices was investigated in this study. Fifteen third generation Sawbones composite tibiae were used as a model. Four different plates were tested: a short spacer plate (OWO) (n=4), a short spacer plate with multi‐directional locking bolts (MSO) (n=5), a prototype version of a long spacer plate with multi‐directional locking bolts (MSOnew) (n=2), and a long medial tibia plate fixator with locking bolts (MPF) (n=4). All opening wedge osteotomies were performed by the same surgeon (PL) in a standardized fashion. Axial compression of the tibiae was performed using a materials testing machine under standardized alignment of the loading axis. Single load to failure tests as well as load‐controlled cyclical failure tests were performed. The required force and cycles to failure were recorded. Osteotomy gap motion was measured using linear displacement transducers. Residual stability after failure of the opposite lateral cortex was analysed. Failure occurred at the lateral cortex bone‐bride in all tested implants. The rigid long plate fixator (MPF) resisted the greatest amount of force (2,881 N) in the single load to failure tests. In the cyclical load‐to‐failure tests, the constructs with MPF resisted more than twice the amount of loading cycles when compared to the short spacer plates. The osteotomy gap motion was smallest in the MPF, with a reduction of the displacements of up to 65, 66 and 88%, when compared to OWO, MSO and MSOnew, respectively. The highest residual stability after failure of the lateral cortex was observed in MPF as well. The results suggest that the implant design strongly influences the primary stability of medial opening wedge tibial osteotomy. A rigid long plate fixator with angle‐stable locking bolts yields the best results.
- 12 November 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (3) , 291-300
Primary stability of four different implants for opening wedge high tibial osteotomy
Since a significant number of implant failures have been reported in association with the procedure of open wedge valgus high tibial osteotomy, the initial biomechanical stability of different fixation devices was investigated in this study. Fifteen third generation Sawbones composite tibiae were used as a model. Four different plates were tested: a short spacer plate (OWO) (n=4), a short spacer plate with multi‐directional locking bolts (MSO) (n=5), a prototype version of a long spacer plate with multi‐directional locking bolts (MSOnew) (n=2), and a long medial tibia plate fixator with locking bolts (MPF) (n=4). All opening wedge osteotomies were performed by the same surgeon (PL) in a standardized fashion. Axial compression of the tibiae was performed using a materials testing machine under standardized alignment of the loading axis. Single load to failure tests as well as load‐controlled cyclical failure tests were performed. The required force and cycles to failure were recorded. Osteotomy gap motion was measured using linear displacement transducers. Residual stability after failure of the opposite lateral cortex was analysed. Failure occurred at the lateral cortex bone‐bride in all tested implants. The rigid long plate fixator (MPF) resisted the greatest amount of force (2,881 N) in the single load to failure tests. In the cyclical load‐to‐failure tests, the constructs with MPF resisted more than twice the amount of loading cycles when compared to the short spacer plates. The osteotomy gap motion was smallest in the MPF, with a reduction of the displacements of up to 65, 66 and 88%, when compared to OWO, MSO and MSOnew, respectively. The highest residual stability after failure of the lateral cortex was observed in MPF as well. The results suggest that the implant design strongly influences the primary stability of medial opening wedge tibial osteotomy. A rigid long plate fixator with angle‐stable locking bolts yields the best results.
- 1 February 2005
- Published by Springer Nature in Arthroskopie
- Vol. 18 (1) , 69-70
Verbesserte Übersicht bei arthroskopischen Eingriffen am Innenmeniskushinterhorn durch perkutanes Needling des Innenbandes
- 1 February 2005
- Published by Springer Nature in Arthroskopie
- Vol. 18 (1) , 69-70
Verbesserte Übersicht bei arthroskopischen Eingriffen am Innenmeniskushinterhorn durch perkutanes Needling des Innenbandes
- 1 November 2004
- Published by Springer Nature in Arthroskopie
- Vol. 17 (4) , 246-255
Open-wedge-Osteotomie: Konzept und erste Erfahrungen
- 1 November 2004
- Published by Springer Nature in Arthroskopie
- Vol. 17 (4) , 246-255
Open-wedge-Osteotomie: Konzept und erste Erfahrungen
- 1 September 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (9) , 795-802
Arthroskopische Meniskuschirurgie: Technisch-operative Verfahren
- 1 September 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (9) , 795-802
Arthroskopische Meniskuschirurgie: Technisch-operative Verfahren
- 1 September 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (9) , 783-794
Arthroskopische Meniskuschirurgie
Eingriffe an den Menisken des Kniegelenks gehören zu den am häufigsten durchgeführten Operationen überhaupt. Die Durchführung in arthroskopischer Technik ist heute allgemeiner Behandlungsstandard und hat mit wenigen Ausnahmen das offene Vorgehen vollkommen abgelöst. Die Arthroskopie ermöglicht die exakte Diagnostik und Klassifikation aller Formen von Meniskusläsionen. Auch heute ist die Teilresektion von irreparabel geschädigtem Meniskusgewebe in vielen Fällen nicht zu vermeiden. Dabei muss möglichst viel gesundes Meniskusgewebe erhalten werden. Rekonstruktionsfähige Risstypen erfordern stets eine arthroskopische Refixation. Dabei sind verschiedene Techniken möglich, die je nach Lokalisation der Läsion unterschiedliche Vor- und Nachteile haben. Mit modernen Implantaten und Instrumentarien zur Meniskusrekonstruktion ist im Vergleich zu konventionellen Techniken in vielen Fällen eine einfachere und mit weniger Morbidität verbundene Rekonstruktion möglich. Der Ersatz von verlorenem Meniskusgewebe ist in Form der Transplantation von Allografts möglich, v. a. am Außenmeniskus sind dabei gute Ergebnisse möglich. Eine neuartige Alternative hierfür ist die arthroskopische Implantation einer biologisch abbaubaren Kollagenmatrix, die partielle Defekte am Innenmeniskus ersetzt. Längerfristige Ergebnisse dieser Therapieformen müssen abgewartet werden. Surgery on the meniscus of the knee joint is one of the most frequently performed operations. The arthroscopic technique currently represents the general treatment standard and except in a few cases has completely superseded the open approach. Arthroscopy facilitates precise diagnosis and classification of all forms of meniscus lesions. In many cases even today partial resection on irreparably damaged meniscus tissue cannot be avoided. The goal is to preserve as much healthy meniscus tissue as possible. Types of tears amenable to reconstruction always require arthroscopic refixation. Various techniques are possible which have different advantages and disadvantages depending on the site of the lesion. In comparison to conventional techniques, in many cases modern implants and instruments make meniscus reconstruction easier entailing less morbidity. Substitution of lost meniscus tissue is possible with allograft transplantation; good results are possible especially on the lateral meniscus. A novel alternative is arthroscopic implantation of a biodegradable collagen matrix, which replaces partial defects on the medial meniscus. Long-term results of this treatment form must be awaited.
- 1 September 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (9) , 783-794
Arthroskopische Meniskuschirurgie
Eingriffe an den Menisken des Kniegelenks gehören zu den am häufigsten durchgeführten Operationen überhaupt. Die Durchführung in arthroskopischer Technik ist heute allgemeiner Behandlungsstandard und hat mit wenigen Ausnahmen das offene Vorgehen vollkommen abgelöst. Die Arthroskopie ermöglicht die exakte Diagnostik und Klassifikation aller Formen von Meniskusläsionen. Auch heute ist die Teilresektion von irreparabel geschädigtem Meniskusgewebe in vielen Fällen nicht zu vermeiden. Dabei muss möglichst viel gesundes Meniskusgewebe erhalten werden. Rekonstruktionsfähige Risstypen erfordern stets eine arthroskopische Refixation. Dabei sind verschiedene Techniken möglich, die je nach Lokalisation der Läsion unterschiedliche Vor- und Nachteile haben. Mit modernen Implantaten und Instrumentarien zur Meniskusrekonstruktion ist im Vergleich zu konventionellen Techniken in vielen Fällen eine einfachere und mit weniger Morbidität verbundene Rekonstruktion möglich. Der Ersatz von verlorenem Meniskusgewebe ist in Form der Transplantation von Allografts möglich, v. a. am Außenmeniskus sind dabei gute Ergebnisse möglich. Eine neuartige Alternative hierfür ist die arthroskopische Implantation einer biologisch abbaubaren Kollagenmatrix, die partielle Defekte am Innenmeniskus ersetzt. Längerfristige Ergebnisse dieser Therapieformen müssen abgewartet werden. Surgery on the meniscus of the knee joint is one of the most frequently performed operations. The arthroscopic technique currently represents the general treatment standard and except in a few cases has completely superseded the open approach. Arthroscopy facilitates precise diagnosis and classification of all forms of meniscus lesions. In many cases even today partial resection on irreparably damaged meniscus tissue cannot be avoided. The goal is to preserve as much healthy meniscus tissue as possible. Types of tears amenable to reconstruction always require arthroscopic refixation. Various techniques are possible which have different advantages and disadvantages depending on the site of the lesion. In comparison to conventional techniques, in many cases modern implants and instruments make meniscus reconstruction easier entailing less morbidity. Substitution of lost meniscus tissue is possible with allograft transplantation; good results are possible especially on the lateral meniscus. A novel alternative is arthroscopic implantation of a biodegradable collagen matrix, which replaces partial defects on the medial meniscus. Long-term results of this treatment form must be awaited.