Mazda Memarsadeghi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mazda Memarsadeghi has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Cornelia Schaefer-Prokop
Department of Radiology, University of Amsterdam, Amsterdam, The Netherlands
3 shared publications- Mathias Prokop
Diagnostic Image Analysis Group, Radboud University Medical Center, Nijmegen, The Netherlands
3 shared publications Gertraud Heinz-Peer
Department of Radiology, Medical University of Vienna, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
2 shared publications- Michael Weber
Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Waehringer Guertel 18–20, 1090 Vienna, Austria
2 shared publications Christian Gäbler
1 shared publication- Christian Seitz
Department of Urology, Medical University of Vienna, Vienna General Hospital, Vienna, Austria
1 shared publication
Latest Publications
- 1 August 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 189 (2) , W60-W64
Unenhanced MDCT in Patients with Suspected Urinary Stone Disease: Do Coronal Reformations Improve Diagnostic Performance?
OBJECTIVE. The objectives of our study were to assess whether coronal reformations improve the diagnostic performance of MDCT in patients with acute flank pain and suspected urinary stone disease; and to determine if performing such reformations from 3-mm-thick sections is sufficient or if it is necessary to perform reformations from thinner sections. MATERIALS AND METHODS. We included 147 consecutive patients (72 women and 75 men; mean age ± SD, 58 ± 18.1 years) with suspected urinary stone disease who underwent unenhanced MDCT. Scans were obtained with a 4 × 1 mm collimation and were reconstructed with a section thickness of 1.25 and 3 mm. We compared the diagnostic yield of 3-mm axial sections with that of coronal reformations reconstructed from 1.25- and 3-mm axial sections. Imaging data were evaluated in random order by two radiologists. The significance of the difference between the axial sections and coronal multiplanar reformations (MPRs) was tested for the number, size, and location of uroliths and for the presence of alternative diagnoses. The time required for review by both observers was recorded. RESULTS. We found uroliths in 72 patients. There was no difference between 3-mm axial sections and coronal reformations from 1.25-mm sections with regard to the number of detected stones (n = 264 for both protocols), whereas coronal reformations from 3-mm sections revealed significantly fewer calcifications (n = 255, p = 0.016). Coronal reformations did not improve the localization of calcifications. Review time, however, was significantly shorter for coronal reformations than for axial sections (p = 0.001); however, coronal reformations were less sensitive than axial sections for the detection of additional findings suggestive of alternative diagnoses in 16 (30%) of 53 patients. CONCLUSION. Coronal reformations from MDCT do not improve urinary stone detection but may reduce evaluation time; however, there is the danger of missing additional findings. Coronal reformations reconstructed from thick (i.e., 3-5 mm) axial sections may result in reduced detection of small stones and should therefore be avoided.
- 1 August 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 189 (2) , W60-W64
Unenhanced MDCT in Patients with Suspected Urinary Stone Disease: Do Coronal Reformations Improve Diagnostic Performance?
OBJECTIVE. The objectives of our study were to assess whether coronal reformations improve the diagnostic performance of MDCT in patients with acute flank pain and suspected urinary stone disease; and to determine if performing such reformations from 3-mm-thick sections is sufficient or if it is necessary to perform reformations from thinner sections. MATERIALS AND METHODS. We included 147 consecutive patients (72 women and 75 men; mean age ± SD, 58 ± 18.1 years) with suspected urinary stone disease who underwent unenhanced MDCT. Scans were obtained with a 4 × 1 mm collimation and were reconstructed with a section thickness of 1.25 and 3 mm. We compared the diagnostic yield of 3-mm axial sections with that of coronal reformations reconstructed from 1.25- and 3-mm axial sections. Imaging data were evaluated in random order by two radiologists. The significance of the difference between the axial sections and coronal multiplanar reformations (MPRs) was tested for the number, size, and location of uroliths and for the presence of alternative diagnoses. The time required for review by both observers was recorded. RESULTS. We found uroliths in 72 patients. There was no difference between 3-mm axial sections and coronal reformations from 1.25-mm sections with regard to the number of detected stones (n = 264 for both protocols), whereas coronal reformations from 3-mm sections revealed significantly fewer calcifications (n = 255, p = 0.016). Coronal reformations did not improve the localization of calcifications. Review time, however, was significantly shorter for coronal reformations than for axial sections (p = 0.001); however, coronal reformations were less sensitive than axial sections for the detection of additional findings suggestive of alternative diagnoses in 16 (30%) of 53 patients. CONCLUSION. Coronal reformations from MDCT do not improve urinary stone detection but may reduce evaluation time; however, there is the danger of missing additional findings. Coronal reformations reconstructed from thick (i.e., 3-5 mm) axial sections may result in reduced detection of small stones and should therefore be avoided.
- 1 August 2006
- Published by Elsevier in European Journal of Radiology
- Vol. 59 (2) , 183-189
Percutaneous radiofrequency ablation of renal tumors: Midterm results in 16 patients
- 1 August 2006
- Published by Elsevier in European Journal of Radiology
- Vol. 59 (2) , 183-189
Percutaneous radiofrequency ablation of renal tumors: Midterm results in 16 patients
- 1 July 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 240 (1) , 169-176
Occult Scaphoid Fractures: Comparison of Multidetector CT and MR Imaging—Initial Experience
To compare the diagnostic performance of multidetector computed tomography (CT) and magnetic resonance (MR) imaging in patients clinically suspected of having a scaphoid fracture and who had normal initial radiographs, with radiographs obtained 6 weeks after trauma as the reference standard. The ethics committee approved the study, and all patients gave written informed consent. Twenty-nine patients (17 male, 12 female; age range, 17-62 years; mean age, 34 years +/- 13) underwent multidetector CT and MR imaging within 6 days after trauma. CT data were obtained with 0.5-mm collimation. For image review, 0.7-mm-thick multiplanar reformations were performed in transverse, coronal, and sagittal planes relative to the wrist. The 1.0-T MR examination consisted of coronal and transverse short inversion time inversion-recovery, coronal and transverse T1-weighted spin-echo, and coronal volume-rendered T2-weighted gradient-echo sequences. Two radiologists analyzed the CT and MR images. A binomial test was used to evaluate the significance of the differences between MR imaging and CT in detection of scaphoid fractures and cortical involvement (P < .05). The 6-week follow-up radiographs depicted a scaphoid fracture in 11 (38%) patients. Eight patients had a cortical fracture, while three patients had only a bandlike lucency within the trabecular portion of the scaphoid. MR imaging depicted all 11 fractures but only three [corrected] cortical fractures. Multidetector CT depicted all eight cortical fractures but failed to depict trabecular fractures. No false-positive fractures were seen on MR or CT images. Differences between MR imaging and CT were not significant for the detection of scaphoid fractures (P = .25) but were significant for cortical involvement (P = .03). Multidetector CT is highly accurate in depicting occult cortical scaphoid fractures but appears inferior to MR imaging in depicting solely trabecular injury. MR imaging is inferior to multidetector CT in depicting cortical involvement.
- 1 July 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 240 (1) , 169-176
Occult Scaphoid Fractures: Comparison of Multidetector CT and MR Imaging—Initial Experience
To compare the diagnostic performance of multidetector computed tomography (CT) and magnetic resonance (MR) imaging in patients clinically suspected of having a scaphoid fracture and who had normal initial radiographs, with radiographs obtained 6 weeks after trauma as the reference standard. The ethics committee approved the study, and all patients gave written informed consent. Twenty-nine patients (17 male, 12 female; age range, 17-62 years; mean age, 34 years +/- 13) underwent multidetector CT and MR imaging within 6 days after trauma. CT data were obtained with 0.5-mm collimation. For image review, 0.7-mm-thick multiplanar reformations were performed in transverse, coronal, and sagittal planes relative to the wrist. The 1.0-T MR examination consisted of coronal and transverse short inversion time inversion-recovery, coronal and transverse T1-weighted spin-echo, and coronal volume-rendered T2-weighted gradient-echo sequences. Two radiologists analyzed the CT and MR images. A binomial test was used to evaluate the significance of the differences between MR imaging and CT in detection of scaphoid fractures and cortical involvement (P < .05). The 6-week follow-up radiographs depicted a scaphoid fracture in 11 (38%) patients. Eight patients had a cortical fracture, while three patients had only a bandlike lucency within the trabecular portion of the scaphoid. MR imaging depicted all 11 fractures but only three [corrected] cortical fractures. Multidetector CT depicted all eight cortical fractures but failed to depict trabecular fractures. No false-positive fractures were seen on MR or CT images. Differences between MR imaging and CT were not significant for the detection of scaphoid fractures (P = .25) but were significant for cortical involvement (P = .03). Multidetector CT is highly accurate in depicting occult cortical scaphoid fractures but appears inferior to MR imaging in depicting solely trabecular injury. MR imaging is inferior to multidetector CT in depicting cortical involvement.
- 1 October 2005
- Published by Springer Nature in Der Radiologe
- Vol. 45 (10) , 915-923
MR-Urographie: Prinzipien, Untersuchungstechniken, Indikationen
MR urography is an evolving and promising technique in the evaluation of the urinary tract. MR urography is currently considered the method of choice for imaging of the renal parenchyma and the collecting systems in patients who cannot undergo routine radiographic studies such as pregnant women, pediatric patients, patients allergic to iodinated contrast agents, or patients with impaired renal function. The future development of MR urography in terms of functional, cellular, and molecular imaging is presently the subject of research. The ability of MR imaging to provide quantitative functional information (e.g., on blood flow, perfusion, glomerular filtration rate, and excretion as well as urine drainage) in addition to morphologic assessment of the parenchyma and the collecting system could lead to a single, "all-in-one approach" examination technique.
- 1 October 2005
- Published by Springer Nature in Der Radiologe
- Vol. 45 (10) , 915-923
MR-Urographie: Prinzipien, Untersuchungstechniken, Indikationen
MR urography is an evolving and promising technique in the evaluation of the urinary tract. MR urography is currently considered the method of choice for imaging of the renal parenchyma and the collecting systems in patients who cannot undergo routine radiographic studies such as pregnant women, pediatric patients, patients allergic to iodinated contrast agents, or patients with impaired renal function. The future development of MR urography in terms of functional, cellular, and molecular imaging is presently the subject of research. The ability of MR imaging to provide quantitative functional information (e.g., on blood flow, perfusion, glomerular filtration rate, and excretion as well as urine drainage) in addition to morphologic assessment of the parenchyma and the collecting system could lead to a single, "all-in-one approach" examination technique.
- 1 May 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 235 (2) , 530-536
Unenhanced Multi–Detector Row CT in Patients Suspected of Having Urinary Stone Disease: Effect of Section Width on Diagnosis
To assess prospectively the effect of section width in multi-detector row computed tomographic (CT) evaluation of patients with acute flank pain who are suspected of having or known to have urinary stone disease. This study was approved by the ethics committee of the authors' university, and written informed consent was obtained from all patients. One hundred forty-seven patients (age range, 11-101 years; mean, 51.4 years +/- 18.7 [standard deviation]) suspected of having urinary stone disease underwent unenhanced multi-detector row CT. CT was performed with four detector rows, a section thickness of 1.0 mm, an effective tube current-time product of 100 mAs, and a tube voltage of 120 kVp (CT dose index, 11.4 mGy). From these data, three sets of transverse images were reconstructed with section widths of 1.5, 3.0, and 5.0 mm and approximately 50% of overlap each. Scans were evaluated in varying random orders by two radiologists for the number, size, and location of uroliths and nephroliths and for the presence of phleboliths, renal cysts, and secondary signs of obstruction. The significance of differences between the numbers of detected calcifications and the numbers of associated abnormalities on the scans obtained with varying section widths was tested with the McNemar test at a P level of less than .05. Spearman rho rank correlation coefficients were calculated to assess the correlation between the presence of uroliths and the presence of secondary signs. Uroliths were found in 72 of 147 (49.0%) patients, and nephroliths were found in 16 patients (10.9%). There was no significant difference between section widths of 1.5 and 3.0 mm with regard to the number of detected stones (264 uroliths and 61 nephroliths for both protocols). Transverse sections 5.0-mm wide revealed significantly fewer uroliths (n = 231; P < .001) and nephroliths (n = 47; P < .016). The final diagnosis was changed in four of 72 patients. All missed renal and ureteral stones measured less than 3 mm in diameter. Overlapping 3-mm sections are sufficient for the detection of urinary stone disease. Small calculi (<3 mm) may be missed on 5.0-mm-thick sections.
- 1 May 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 235 (2) , 530-536
Unenhanced Multi–Detector Row CT in Patients Suspected of Having Urinary Stone Disease: Effect of Section Width on Diagnosis
To assess prospectively the effect of section width in multi-detector row computed tomographic (CT) evaluation of patients with acute flank pain who are suspected of having or known to have urinary stone disease. This study was approved by the ethics committee of the authors' university, and written informed consent was obtained from all patients. One hundred forty-seven patients (age range, 11-101 years; mean, 51.4 years +/- 18.7 [standard deviation]) suspected of having urinary stone disease underwent unenhanced multi-detector row CT. CT was performed with four detector rows, a section thickness of 1.0 mm, an effective tube current-time product of 100 mAs, and a tube voltage of 120 kVp (CT dose index, 11.4 mGy). From these data, three sets of transverse images were reconstructed with section widths of 1.5, 3.0, and 5.0 mm and approximately 50% of overlap each. Scans were evaluated in varying random orders by two radiologists for the number, size, and location of uroliths and nephroliths and for the presence of phleboliths, renal cysts, and secondary signs of obstruction. The significance of differences between the numbers of detected calcifications and the numbers of associated abnormalities on the scans obtained with varying section widths was tested with the McNemar test at a P level of less than .05. Spearman rho rank correlation coefficients were calculated to assess the correlation between the presence of uroliths and the presence of secondary signs. Uroliths were found in 72 of 147 (49.0%) patients, and nephroliths were found in 16 patients (10.9%). There was no significant difference between section widths of 1.5 and 3.0 mm with regard to the number of detected stones (264 uroliths and 61 nephroliths for both protocols). Transverse sections 5.0-mm wide revealed significantly fewer uroliths (n = 231; P < .001) and nephroliths (n = 47; P < .016). The final diagnosis was changed in four of 72 patients. All missed renal and ureteral stones measured less than 3 mm in diameter. Overlapping 3-mm sections are sufficient for the detection of urinary stone disease. Small calculi (<3 mm) may be missed on 5.0-mm-thick sections.