Dimitrios Stylianos Mastrokalos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dimitrios Stylianos Mastrokalos has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Hans H. Paessler
Department for Knee and Foot Surgery Sport Traumatology, ATOS‐Clinic Heidelberg Heidelberg Germany
5 shared publications- Michael Hantes
Department of Orthopaedic Surgery and Musculoskeletal Trauma, Faculty of Medicine, School of Health Sciences, University of Thessaly, 41223 Larissa, Greece
5 shared publications - Andreas F. Mavrogenis
First Department of Orthopaedics, National and Kapodistrian University of Athens, School of Medicine
3 shared publications Dimitrios Koulalis
General University Hospital ATTIKO, 1st Surgical Orthopaedic Department of N.K.U.A., Rimini 1, Chaidari, 12462, Greece
2 shared publicationsHans H Paessler
2 shared publicationsPanayotis N. Soucacos
2 shared publications
Latest Publications
- 6 March 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-8
Soluble urokinase plasminogen activator receptor biomarker is not a predictor of mortality in high-risk hip fracture patients
Background The soluble urokinase plasminogen activator receptor (SuPAR) is a biomarker of inflammation and immune activation that has been related with mortality in a vast spectrum of diseases in the elderly. Its prognostic value in preoperative evaluation for non-cardiac surgery has been promising. However, up to date there are no studies in high-risk patients undergoing hip fracture surgery. Therefore, we performed this prospective study aims to evaluate the prognostic value of SuPAR and other common clinical, echocardiographic, and blood biomarkers for the 1-year survival of high-risk hip fracture surgery patients. Methods We studied 46 patients with hip fracture that underwent hip fracture surgery from 2019 to 2024. There were 10 men and 36 women, over 65 years of age (mean, 85 ± 8 years) with at least one high-risk characteristic (dementia, chronic immobilization, age > 90 years). Upon admission, complete clinical and laboratory assessments, including electrocardiogram and cardiac ultrasonography, radiographs, and blood sampling, were conducted. Serum blood levels of SuPAR as well as natriuretic peptides and troponin I were measured. The Katz index of frailty was calculated. The patients were followed for 1 year after admission and hip fracture surgery. At that time, the patients or their relatives were contacted through telephone, and their 1-year survival was documented. Results Overall, 25 (54.3%) patients were dead at 1-year examination. There was no significant difference in baseline values of SuPAR between patients dead or alive at follow-up (6.30 ng/dl [range, 4.95–7.05 ng/dl] vs. 6.25 ng/dl [4.25–9.05 ng/dl], respectively; p value = 0.767), and SuPAR has not been related to 1-year mortality (HR 0.802; 95% CI 0.248–2.595; p value = 0.712). The only univariate and multivariate predictors of survival were age (HR 1.098; 95% CI 1.003–1.181; p = 0.041) and Katz index ≤ 4 (HR 4.490; 95% CI 1.180–17.093; p = 0.028). Conclusion This study showed that SuPAR is not a predictive factor for 1-year mortality in high-risk patients undergoing hip fracture surgery. Older age and Katz index score ≤ 4 were the only independent predictors of 1-year mortality. Therefore, although no definite conclusion can be drawn from such a small number of patients, no trend in mortality for this measurement has been observed, suggesting SuPAR and similar biomarkers should not be considered in the evaluation of mortality in high-risk hip fracture patients.
- 6 March 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-8
Soluble urokinase plasminogen activator receptor biomarker is not a predictor of mortality in high-risk hip fracture patients
Background The soluble urokinase plasminogen activator receptor (SuPAR) is a biomarker of inflammation and immune activation that has been related with mortality in a vast spectrum of diseases in the elderly. Its prognostic value in preoperative evaluation for non-cardiac surgery has been promising. However, up to date there are no studies in high-risk patients undergoing hip fracture surgery. Therefore, we performed this prospective study aims to evaluate the prognostic value of SuPAR and other common clinical, echocardiographic, and blood biomarkers for the 1-year survival of high-risk hip fracture surgery patients. Methods We studied 46 patients with hip fracture that underwent hip fracture surgery from 2019 to 2024. There were 10 men and 36 women, over 65 years of age (mean, 85 ± 8 years) with at least one high-risk characteristic (dementia, chronic immobilization, age > 90 years). Upon admission, complete clinical and laboratory assessments, including electrocardiogram and cardiac ultrasonography, radiographs, and blood sampling, were conducted. Serum blood levels of SuPAR as well as natriuretic peptides and troponin I were measured. The Katz index of frailty was calculated. The patients were followed for 1 year after admission and hip fracture surgery. At that time, the patients or their relatives were contacted through telephone, and their 1-year survival was documented. Results Overall, 25 (54.3%) patients were dead at 1-year examination. There was no significant difference in baseline values of SuPAR between patients dead or alive at follow-up (6.30 ng/dl [range, 4.95–7.05 ng/dl] vs. 6.25 ng/dl [4.25–9.05 ng/dl], respectively; p value = 0.767), and SuPAR has not been related to 1-year mortality (HR 0.802; 95% CI 0.248–2.595; p value = 0.712). The only univariate and multivariate predictors of survival were age (HR 1.098; 95% CI 1.003–1.181; p = 0.041) and Katz index ≤ 4 (HR 4.490; 95% CI 1.180–17.093; p = 0.028). Conclusion This study showed that SuPAR is not a predictive factor for 1-year mortality in high-risk patients undergoing hip fracture surgery. Older age and Katz index score ≤ 4 were the only independent predictors of 1-year mortality. Therefore, although no definite conclusion can be drawn from such a small number of patients, no trend in mortality for this measurement has been observed, suggesting SuPAR and similar biomarkers should not be considered in the evaluation of mortality in high-risk hip fracture patients.
- Open Access
- 10 February 2025
- Published by EDP Sciences in SICOT-J
- Vol. 11, 8
Limited accuracy of transtibial aiming for anatomical femoral tunnel positioning in ACL reconstruction
Background: Anterior cruciate ligament (ACL) rupture is a common knee injury, and with advancements in knee arthroscopy, ACL reconstruction has become common. Techniques like single-double bundle and femoral tunnel drilling via transtibial or anteromedial portal approaches are available. This study evaluates the accuracy of femoral tunnel placement via these approaches in single-bundle ACL reconstruction. Materials and methods: Forty-three ACL reconstructions using hamstring grafts were analyzed. Initially, femoral tunnels were drilled via the anteromedial portal from 09:30 to 10:00 (14:00 to 14:30 for left knees). Tibial tunnels (mean anteroposterior angle: 63.5°, sagittal: 64.2°) were then created with the same diameter, accompanied by radiological documentation. A femoral aiming device was used to place a K-wire at the center of the femoral tunnel, recorded photographically. Tunnel diameters included 7 mm (20 cases), 7.5 mm (11 cases), 8 mm (7 cases), 8.5 mm (3 cases), and 9 mm (1 case). Two observers evaluated all radiological and photographic data, focusing on the deviation of the transtibial K-wire from the femoral tunnel center. Results: Of 38 evaluated cases, the transtibial K-wire was within the femoral tunnel in 11 cases (28.9%) – 7 cases with 7 mm, 2 cases each with 7.5 mm and 8 mm diameters. In 23 cases (60.5%), the K-wire was at the perimeter or outside the femoral tunnel – 11 cases with 7 mm, 8 with 7.5 mm, 4 with 8 mm, 3 with 8.5 mm, and 1 with 9 mm diameters. Conclusion: Transtibial aiming for anatomical femoral tunnel positioning is challenging. No significant correlation was found between the transtibial deviation and the tibial tunnel diameter.
- 10 February 2025
- Published by EDP Sciences in SICOT-J
- Vol. 11, 8
Open AccessLimited accuracy of transtibial aiming for anatomical femoral tunnel positioning in ACL reconstruction
Background: Anterior cruciate ligament (ACL) rupture is a common knee injury, and with advancements in knee arthroscopy, ACL reconstruction has become common. Techniques like single-double bundle and femoral tunnel drilling via transtibial or anteromedial portal approaches are available. This study evaluates the accuracy of femoral tunnel placement via these approaches in single-bundle ACL reconstruction. Materials and methods: Forty-three ACL reconstructions using hamstring grafts were analyzed. Initially, femoral tunnels were drilled via the anteromedial portal from 09:30 to 10:00 (14:00 to 14:30 for left knees). Tibial tunnels (mean anteroposterior angle: 63.5°, sagittal: 64.2°) were then created with the same diameter, accompanied by radiological documentation. A femoral aiming device was used to place a K-wire at the center of the femoral tunnel, recorded photographically. Tunnel diameters included 7 mm (20 cases), 7.5 mm (11 cases), 8 mm (7 cases), 8.5 mm (3 cases), and 9 mm (1 case). Two observers evaluated all radiological and photographic data, focusing on the deviation of the transtibial K-wire from the femoral tunnel center. Results: Of 38 evaluated cases, the transtibial K-wire was within the femoral tunnel in 11 cases (28.9%) – 7 cases with 7 mm, 2 cases each with 7.5 mm and 8 mm diameters. In 23 cases (60.5%), the K-wire was at the perimeter or outside the femoral tunnel – 11 cases with 7 mm, 8 with 7.5 mm, 4 with 8 mm, 3 with 8.5 mm, and 1 with 9 mm diameters. Conclusion: Transtibial aiming for anatomical femoral tunnel positioning is challenging. No significant correlation was found between the transtibial deviation and the tibial tunnel diameter.
- Open Access
- 2 November 2021
- Published by Springer Nature in Cureus
- Vol. 13 (11)
Comparison of Bone-Patella Tendon-Bone and Four-Strand Hamstring Tendon Grafts for Anterior Cruciate Ligament Reconstruction: A Prospective Study
To date, the proper choice of graft for anterior cruciate ligament (ACL) reconstruction remains a matter of conflict. We aimed to compare the clinical and functional outcomes of the two most commonly utilized autografts, bone-patella tendon-bone (BPTB) and four-strand hamstring tendon (HT) graft, at 6 and 12 months after surgery. In a prospective randomized study, we included a total of 60 patients undergoing ACL reconstruction, thirty in BPTB and thirty in HT group. All patients were amateur athletes and were evaluated at 6 and 12 months after surgery for: (a) postoperative functionality of the operated knee by the Tegner, the Lysholm and the International Knee Documentation Committee (IKDC) scoring scales, (b) anterior cruciate ligament (ACL) instability of the operated knee compared to the healthy contralateral knee by the KT-1000 arthrometer and (c) the extension and flexion muscle strength of the operated knee by a CYBEX isokinetic dynamometer. Patients in the two groups did not differ regarding demographics, and pre-injury functionality status. Significantly more patients in the HT group (n=6) compared to the BPTB group (n=1) experienced ACL re-rupture and underwent revision surgery before follow-up end (p=0.044). All patients, regardless of graft, showed significant improvement within each group of functional assessments by Lysholm, Tegner and IKDC scores, as well as of Cybex measurements -with an increase of peak torque at 60° extension and 180°extension and 60° flexion and 180° flexion- at 12 months compared to 6 months follow-up (p<0.05). However, there was no difference between the two groups regarding knee function improvement or extension measurements neither at 6 nor 12 months. Contrarily, the BPTB graft group had higher values of peak torque (Nm) at 60° and 180° flexion compared to the HT group, both at 6 (p=0.014 and 0.029, respectively) and 12 months (p=0.033 and 0.030, respectively). Postoperative stability was similar between the two groups at 12 months (p=0.519). Both BPTB and HT grafts present with benefits and drawbacks and remain viable autograft options for primary ACL reconstruction as each has, although HT grafts seem to be more susceptible to re-rupture. The graft selection should be based on the needs and activities of each patient.
- 2 November 2021
- Published by Springer Nature in Cureus
- Vol. 13 (11)
Open AccessComparison of Bone-Patella Tendon-Bone and Four-Strand Hamstring Tendon Grafts for Anterior Cruciate Ligament Reconstruction: A Prospective Study
To date, the proper choice of graft for anterior cruciate ligament (ACL) reconstruction remains a matter of conflict. We aimed to compare the clinical and functional outcomes of the two most commonly utilized autografts, bone-patella tendon-bone (BPTB) and four-strand hamstring tendon (HT) graft, at 6 and 12 months after surgery. In a prospective randomized study, we included a total of 60 patients undergoing ACL reconstruction, thirty in BPTB and thirty in HT group. All patients were amateur athletes and were evaluated at 6 and 12 months after surgery for: (a) postoperative functionality of the operated knee by the Tegner, the Lysholm and the International Knee Documentation Committee (IKDC) scoring scales, (b) anterior cruciate ligament (ACL) instability of the operated knee compared to the healthy contralateral knee by the KT-1000 arthrometer and (c) the extension and flexion muscle strength of the operated knee by a CYBEX isokinetic dynamometer. Patients in the two groups did not differ regarding demographics, and pre-injury functionality status. Significantly more patients in the HT group (n=6) compared to the BPTB group (n=1) experienced ACL re-rupture and underwent revision surgery before follow-up end (p=0.044). All patients, regardless of graft, showed significant improvement within each group of functional assessments by Lysholm, Tegner and IKDC scores, as well as of Cybex measurements -with an increase of peak torque at 60° extension and 180°extension and 60° flexion and 180° flexion- at 12 months compared to 6 months follow-up (p<0.05). However, there was no difference between the two groups regarding knee function improvement or extension measurements neither at 6 nor 12 months. Contrarily, the BPTB graft group had higher values of peak torque (Nm) at 60° and 180° flexion compared to the HT group, both at 6 (p=0.014 and 0.029, respectively) and 12 months (p=0.033 and 0.030, respectively). Postoperative stability was similar between the two groups at 12 months (p=0.519). Both BPTB and HT grafts present with benefits and drawbacks and remain viable autograft options for primary ACL reconstruction as each has, although HT grafts seem to be more susceptible to re-rupture. The graft selection should be based on the needs and activities of each patient.
- 1 September 2012
- Published by Wiley in Arthroscopy
- Vol. 28 (9S)
Paper 42: Autologous Osteochondral Grafts in the Treatment of Focal Chondral Defects of the Femoral Head: An Experimental Study in Rabbits
- 1 September 2012
- Published by Wiley in Arthroscopy
- Vol. 28 (9S)
Paper 42: Autologous Osteochondral Grafts in the Treatment of Focal Chondral Defects of the Femoral Head: An Experimental Study in Rabbits
- 1 January 2011
- Published by Begell House Inc. Publishers in Journal of Long-Term Effects of Medical Implants
- Vol. 21 (4) , 339-348
Kinematic and Kinetic Analysis of the Knee Joint before and after a PCL Retaining Total Knee Replacement during Gait and Single Step Ascent
The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p < 0.004), step length (preoperative mean = 0.49, postoperative mean = 0.54; p < 0.01) , and walking velocity (preoperative mean = 0.78, preoperatively, postoperative mean = 0.99; p < 0.001). Decreases in stance duration percentage and knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.
- 1 January 2011
- Published by Begell House Inc. Publishers in Journal of Long-Term Effects of Medical Implants
- Vol. 21 (4) , 339-348
Kinematic and Kinetic Analysis of the Knee Joint before and after a PCL Retaining Total Knee Replacement during Gait and Single Step Ascent
The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p < 0.004), step length (preoperative mean = 0.49, postoperative mean = 0.54; p < 0.01) , and walking velocity (preoperative mean = 0.78, preoperatively, postoperative mean = 0.99; p < 0.001). Decreases in stance duration percentage and knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.
- 1 January 2008
- Published by Tohoku University Medical Press in The Tohoku Journal of Experimental Medicine
- Vol. 216 (3) , 197-204
Mesenteric Ischemia: Still a Deadly Puzzle for the Medical Community
The main goal of this article is to update etiology, epidemiology, diagnosis, treatment and outcome of the various causes of mesenteric ischemia in order to elucidate its labyrinthine clinical riddle, by reviewing the current English medical literature. Mesenteric ischemia is a quite uncommon disorder, observed in the emergency department. It is a life-threatening vascular emergency that requires early diagnosis and intervention to restore mesenteric blood flow and to prevent bowel necrosis and patient death. Consequently, it is a vital diagnosis to make because of its high mortality rate and its thorny complications. The underlying causes vary, and the prognosis depends on the specific findings during clinical examination. Vague and nonspecific clinical findings and limitations of diagnostic studies make the diagnosis a significant challenge. The prognosis of acute mesenteric ischemia of any type is grave. The complications following this medical jigsaw puzzle are also severe. Patients in whom the diagnosis is missed until infarction occurs have a mortality rate of 90%. Even with good treatment, up to 50-80% of patients die. Survivors of extensive bowel resection face lifelong disability. Despite the progress in understanding the pathogenesis of mesenteric ischemia and the development of treatment modalities, the entity remains a diagnostic challenge for clinicians. Delay in diagnosis contributes to a high mortality rate. Early diagnosis and adequate treatment can improve the clinical outcome. Even if diagnostic modalities have improved since the first successful attempts to confront effectively this clinical entity, mesenteric ischemia still remains a lethal diagnostic enigma for the medical community.
- 1 January 2008
- Published by Tohoku University Medical Press in The Tohoku Journal of Experimental Medicine
- Vol. 216 (3) , 197-204
Mesenteric Ischemia: Still a Deadly Puzzle for the Medical Community
The main goal of this article is to update etiology, epidemiology, diagnosis, treatment and outcome of the various causes of mesenteric ischemia in order to elucidate its labyrinthine clinical riddle, by reviewing the current English medical literature. Mesenteric ischemia is a quite uncommon disorder, observed in the emergency department. It is a life-threatening vascular emergency that requires early diagnosis and intervention to restore mesenteric blood flow and to prevent bowel necrosis and patient death. Consequently, it is a vital diagnosis to make because of its high mortality rate and its thorny complications. The underlying causes vary, and the prognosis depends on the specific findings during clinical examination. Vague and nonspecific clinical findings and limitations of diagnostic studies make the diagnosis a significant challenge. The prognosis of acute mesenteric ischemia of any type is grave. The complications following this medical jigsaw puzzle are also severe. Patients in whom the diagnosis is missed until infarction occurs have a mortality rate of 90%. Even with good treatment, up to 50-80% of patients die. Survivors of extensive bowel resection face lifelong disability. Despite the progress in understanding the pathogenesis of mesenteric ischemia and the development of treatment modalities, the entity remains a diagnostic challenge for clinicians. Delay in diagnosis contributes to a high mortality rate. Early diagnosis and adequate treatment can improve the clinical outcome. Even if diagnostic modalities have improved since the first successful attempts to confront effectively this clinical entity, mesenteric ischemia still remains a lethal diagnostic enigma for the medical community.
- 1 January 2008
- Published by SLACK, Inc. in Orthopedics
- Vol. 31 (1) , 68
Changes of the Posterior Meniscal Horn Height During Loading: An In Vivo Magnetic Resonance Imaging Study
Orthopedics | Abstract This in vivo magnetic resonance imaging study evaluated the deformation of the meniscal posterior horn during loading. Images of the medial and lateral meniscus were obtained in 20 normal knees in 0° and 30° of flexion, and the height of the posterior horn of both menisci was measured. Mean height of the posterior horn of the medial meniscus under no load and load equal to 50%
- 1 January 2008
- Published by SLACK, Inc. in Orthopedics
- Vol. 31 (1) , 68
Changes of the Posterior Meniscal Horn Height During Loading: An In Vivo Magnetic Resonance Imaging Study
Orthopedics | Abstract This in vivo magnetic resonance imaging study evaluated the deformation of the meniscal posterior horn during loading. Images of the medial and lateral meniscus were obtained in 20 normal knees in 0° and 30° of flexion, and the height of the posterior horn of both menisci was measured. Mean height of the posterior horn of the medial meniscus under no load and load equal to 50%
- 17 April 2007
- Published by Wiley in Arthroscopy
- Vol. 24 (6) , 732-733
Allergic Reaction to Biodegradable Interference Poly‐L‐Lactic Acid Screws After Anterior Cruciate Ligament Reconstruction With Bone–Patellar Tendon–Bone Graft
We report a case of a systemic allergic reaction to biodegradable poly‐L‐lactic acid (PLLA) interference screws after anterior cruciate ligament (ACL) reconstruction with bone–patellar tendon–bone graft. A 30‐year‐old patient complained of certain symptoms, such as an inability to focus mentally, rash on the right femur, chronic fatigue, decreased sex drive, and localized alopecia, 3 months after ACL reconstruction in the right knee. Two biodegradable PLLA interference screws had been used for proximal and distal graft fixation. Allergy testing showed a value of 7 in PLLA antigen. After removal of 1 screw in August 2000, the patient reported marked improvement, but some symptoms remained. In July 2001 he underwent arthroscopic revision ACL reconstruction with hamstrings via an implant‐free technique with intensive debridement of the tunnels and removal of all scar tissue and screw rests. All symptoms disappeared, and the PLLA antigen number fell from 3 to “concentrate” 2 months postoperatively.
- 17 April 2007
- Published by Wiley in Arthroscopy
- Vol. 24 (6) , 732-733
Allergic Reaction to Biodegradable Interference Poly‐L‐Lactic Acid Screws After Anterior Cruciate Ligament Reconstruction With Bone–Patellar Tendon–Bone Graft
We report a case of a systemic allergic reaction to biodegradable poly‐L‐lactic acid (PLLA) interference screws after anterior cruciate ligament (ACL) reconstruction with bone–patellar tendon–bone graft. A 30‐year‐old patient complained of certain symptoms, such as an inability to focus mentally, rash on the right femur, chronic fatigue, decreased sex drive, and localized alopecia, 3 months after ACL reconstruction in the right knee. Two biodegradable PLLA interference screws had been used for proximal and distal graft fixation. Allergy testing showed a value of 7 in PLLA antigen. After removal of 1 screw in August 2000, the patient reported marked improvement, but some symptoms remained. In July 2001 he underwent arthroscopic revision ACL reconstruction with hamstrings via an implant‐free technique with intensive debridement of the tunnels and removal of all scar tissue and screw rests. All symptoms disappeared, and the PLLA antigen number fell from 3 to “concentrate” 2 months postoperatively.
- 1 October 2006
- Published by Wiley in Arthroscopy
- Vol. 22 (10) , 1140.e1-3
Arthroscopic Debridement and Irrigation of Periprosthetic Total Elbow Infection
We report on a case of arthroscopic treatment of septic arthritis of the elbow joint in a 65‐year‐old man with an elbow endoprosthesis. Two months after arthroplasty of the elbow joint, the patient developed acute septic arthritis of the right elbow. Methicillin‐sensitive Staphylococcus aureus was identified as the causative organism. Six days after the onset of symptoms, the patient was treated with a single arthroscopic procedure of the infected periprosthetic joint, including irrigation with 5 L of Ringer's lactate solution, debridement, and partial synovectomy with a 4.5‐mm curved shaver. Intravenous antibiotic therapy was also used for 3 months including rifampicine and fucidic acid according to the intraoperative cultures. The acutely infected total elbow arthroplasty could be cured without removal of the endoprosthesis of the elbow. Ten months postoperatively, the patient remains free of symptoms and his blood rates are within normal limits.
- 1 October 2006
- Published by Wiley in Arthroscopy
- Vol. 22 (10) , 1140.e1-3
Arthroscopic Debridement and Irrigation of Periprosthetic Total Elbow Infection
We report on a case of arthroscopic treatment of septic arthritis of the elbow joint in a 65‐year‐old man with an elbow endoprosthesis. Two months after arthroplasty of the elbow joint, the patient developed acute septic arthritis of the right elbow. Methicillin‐sensitive Staphylococcus aureus was identified as the causative organism. Six days after the onset of symptoms, the patient was treated with a single arthroscopic procedure of the infected periprosthetic joint, including irrigation with 5 L of Ringer's lactate solution, debridement, and partial synovectomy with a 4.5‐mm curved shaver. Intravenous antibiotic therapy was also used for 3 months including rifampicine and fucidic acid according to the intraoperative cultures. The acutely infected total elbow arthroplasty could be cured without removal of the endoprosthesis of the elbow. Ten months postoperatively, the patient remains free of symptoms and his blood rates are within normal limits.