Haitham M. Bahaidaraha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haitham M. Bahaidaraha has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Abdelsalam Al Sarkhi
Mechanical Engineering Department, Center for Integrative Petroleum Research, King Fahd University of Petroleum & Minerals, Dhahran, Saudi Arabia
1 shared publication - Ahmet Ziyaettin Sahin
Mechanical Engineering Department, King Fahd University of Petroleum and Minerals (KFUPM), Dhahran 31261, Saudi Arabia
1 shared publication - Amin A. Mohammed
Mechanical Engineering Department, King Fahd University of Petroleum & Minerals, P.O. Box 8064, Dhahran 31261, Saudi Arabia
1 shared publication - Bilal Tanweer
Mechanical Engineering Department, King Fahd University of Petroleum & Minerals, Dhahran-31261, Saudi Arabia
1 shared publication - Dahiru Umar Lawal
Mechanical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
1 shared publication - Diaa Afaneh
King Fahd Univ Petr & Minerals, Mech Engn Dept, Dhahran, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 22 March 2024
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 22
Novel integration of thermoelectric distiller with direct contact membrane distillation
- 22 March 2024
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 22
Open AccessNovel integration of thermoelectric distiller with direct contact membrane distillation
- Open Access
- 11 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (10) , 2675
Numerical Study on Generalized Heat and Mass in Casson Fluid with Hybrid Nanostructures
The rheological model for yield stress exhibiting fluid and the basic laws for fluid flow and transport of heat and mass are used for the formulation of problems associated with the enhancement of heat and mass due to dispersion of nanoparticles in Casson. The heat and mass transfer obey non-Fourier’s laws and the generalized Fick’s law, respectively. Model problems are incorporated by thermal relaxation times for heat and mass. Transfer of heat energy and relaxation time are inversely proportional, and the same is the case for mass transport and concentration relaxation time. A porous medium force is responsible for controlling the momentum thickness. The yield stress parameter and diffusion of momentum in Casson fluid are noticed to be inversely proportional with each other. The concentration gradient enhances the energy transfer, and temperature gradient causes an enhancement diffusion of solute in Casson fluid. FEM provides convergent solutions. The relaxation time phenomenon is responsible for the restoration of thermal and solutal changes. Due to that, the thermal and solutal equilibrium states can be restored. The phenomenon of yield stress is responsible for controlling the momentum boundary layer thickness. A porous medium exerts a retarding force on the flow, and therefore, a deceleration in flow is observed. The thermal efficiency of Casson fluid is greater than the thermal efficiency of Casson fluid.- 11 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (10) , 2675
Open AccessNumerical Study on Generalized Heat and Mass in Casson Fluid with Hybrid Nanostructures
The rheological model for yield stress exhibiting fluid and the basic laws for fluid flow and transport of heat and mass are used for the formulation of problems associated with the enhancement of heat and mass due to dispersion of nanoparticles in Casson. The heat and mass transfer obey non-Fourier’s laws and the generalized Fick’s law, respectively. Model problems are incorporated by thermal relaxation times for heat and mass. Transfer of heat energy and relaxation time are inversely proportional, and the same is the case for mass transport and concentration relaxation time. A porous medium force is responsible for controlling the momentum thickness. The yield stress parameter and diffusion of momentum in Casson fluid are noticed to be inversely proportional with each other. The concentration gradient enhances the energy transfer, and temperature gradient causes an enhancement diffusion of solute in Casson fluid. FEM provides convergent solutions. The relaxation time phenomenon is responsible for the restoration of thermal and solutal changes. Due to that, the thermal and solutal equilibrium states can be restored. The phenomenon of yield stress is responsible for controlling the momentum boundary layer thickness. A porous medium exerts a retarding force on the flow, and therefore, a deceleration in flow is observed. The thermal efficiency of Casson fluid is greater than the thermal efficiency of Casson fluid. - 19 January 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (3) , 2833-2844
Influence of the 2-phase Flow Models on Prediction of Absorber Tube Performance
- 19 January 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (3) , 2833-2844
Influence of the 2-phase Flow Models on Prediction of Absorber Tube Performance
- 28 June 2019
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 141 (12) , 1-32
Solar-Assisted Liquid Desiccant Dehumidification Using Hollow-Fiber and Parallel-Plate Membrane Dehumidifiers: Comparative Analysis
In hot and humid climates, air conditioning is an energy-intensive process due to the latent heat load. A unitary air conditioner system is proposed, here, to reduce the latent heat of the humid air using a liquid desiccant followed by an evaporative cooling system. The heat liberated by the desiccant is removed by a solution to the solution heat exchanger. To restore the concentration of the liquid desiccant, the desiccant solution is regenerated by any low-temperature heat source such as solar energy. In order to make the system compact, the membrane heat exchanger is used for the dehumidifier and regenerator. This paper presents the numerical investigation of heat and mass transfer characteristics of a selected membrane dehumidifier under different climatic parameters. Membrane-based parallel-plate and hollow-fiber exchangers are used for this application. A parallel-plate heat-and-mass exchanger (contactor) is composed of a series of plate-type membrane sheets to form channels. On the other hand, hollow-fiber membranes are packed in a shell to form a shell-and-tube heat-and-mass exchanger. The two streams of both contactors are in a counter parallel flow, separated by micro-porous semi-permeable hydrophobic membranes. In this research, the equations governing the transport of heat and mass between the two streams along with the membrane effect in both contactors are solved numerically. The results are compared at different number-of-transfer units (NTU) on the airside and thermal capacity ratios. It is found that the hollow fiber is more efficient than the parallel plate.
- 28 June 2019
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 141 (12) , 1-32
Solar-Assisted Liquid Desiccant Dehumidification Using Hollow-Fiber and Parallel-Plate Membrane Dehumidifiers: Comparative Analysis
In hot and humid climates, air conditioning is an energy-intensive process due to the latent heat load. A unitary air conditioner system is proposed, here, to reduce the latent heat of the humid air using a liquid desiccant followed by an evaporative cooling system. The heat liberated by the desiccant is removed by a solution to the solution heat exchanger. To restore the concentration of the liquid desiccant, the desiccant solution is regenerated by any low-temperature heat source such as solar energy. In order to make the system compact, the membrane heat exchanger is used for the dehumidifier and regenerator. This paper presents the numerical investigation of heat and mass transfer characteristics of a selected membrane dehumidifier under different climatic parameters. Membrane-based parallel-plate and hollow-fiber exchangers are used for this application. A parallel-plate heat-and-mass exchanger (contactor) is composed of a series of plate-type membrane sheets to form channels. On the other hand, hollow-fiber membranes are packed in a shell to form a shell-and-tube heat-and-mass exchanger. The two streams of both contactors are in a counter parallel flow, separated by micro-porous semi-permeable hydrophobic membranes. In this research, the equations governing the transport of heat and mass between the two streams along with the membrane effect in both contactors are solved numerically. The results are compared at different number-of-transfer units (NTU) on the airside and thermal capacity ratios. It is found that the hollow fiber is more efficient than the parallel plate.
- 18 February 2019
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 141 (5)
Vertical Axis Wind Turbine Aerodynamics: Summary and Review of Momentum Models
Momentum models or streamtube models represent one of the fundamental approaches in modeling the aerodynamics of straight bladed vertical axis wind turbine (SB-VAWT) of Darrieus type. They are based on momentum (actuator disk) theory and widely used in performance evaluation of VAWTs. In this short review, the authors have strived to compile the basic momentum models that have been widely assumed in the literature for design and performance estimation of SB-VAWTs of Darrieus type. A comprehensive demonstration of the formulation needed for the implantation of these models is also proposed. Three streamtube models are investigated in this paper, namely, the single streamtube (SST), the multiple streamtube (MST), and the double multiple streamtube (DMST) models. Each of these models has it merits and demerits which are also thoroughly discussed in this review.
- 18 February 2019
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 141 (5)
Vertical Axis Wind Turbine Aerodynamics: Summary and Review of Momentum Models
Momentum models or streamtube models represent one of the fundamental approaches in modeling the aerodynamics of straight bladed vertical axis wind turbine (SB-VAWT) of Darrieus type. They are based on momentum (actuator disk) theory and widely used in performance evaluation of VAWTs. In this short review, the authors have strived to compile the basic momentum models that have been widely assumed in the literature for design and performance estimation of SB-VAWTs of Darrieus type. A comprehensive demonstration of the formulation needed for the implantation of these models is also proposed. Three streamtube models are investigated in this paper, namely, the single streamtube (SST), the multiple streamtube (MST), and the double multiple streamtube (DMST) models. Each of these models has it merits and demerits which are also thoroughly discussed in this review.
- Open Access
- 3 August 2016
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 8 (8)
Entropy generation during fluid flow in sharp edge wavy channels with horizontal pitch
In this study, the volumetric entropy generation rate is analyzed in sharp edge wavy channels. A two-dimensional steadily developing fluid flow is considered. Air is considered as the working fluid in the numerical analysis. Two parameters, Reynolds number (Re) and the horizontal-pitch-to-module-length ratio, are considered as variables. The effect of these variables on the volumetric entropy generation is analyzed numerically using a finite volume technique. Domain discretization was made using a body-fitted coordinate system. The volumetric entropy generation profiles for varying Re number and the horizontal pitch are discussed. It is found that the total entropy generation increases considerably with the increase in the Re number. For the Re number range of 25–400, the total entropy generation in the second module near the inlet varied from 0.38 to 18922.67 W/K, respectively. However, the entropy generation rate was found to decrease along the channel through the modules, as the periodic steady conditions were approached in the subsequent modules.
- 3 August 2016
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 8 (8)
Open AccessEntropy generation during fluid flow in sharp edge wavy channels with horizontal pitch
In this study, the volumetric entropy generation rate is analyzed in sharp edge wavy channels. A two-dimensional steadily developing fluid flow is considered. Air is considered as the working fluid in the numerical analysis. Two parameters, Reynolds number (Re) and the horizontal-pitch-to-module-length ratio, are considered as variables. The effect of these variables on the volumetric entropy generation is analyzed numerically using a finite volume technique. Domain discretization was made using a body-fitted coordinate system. The volumetric entropy generation profiles for varying Re number and the horizontal pitch are discussed. It is found that the total entropy generation increases considerably with the increase in the Re number. For the Re number range of 25–400, the total entropy generation in the second module near the inlet varied from 0.38 to 18922.67 W/K, respectively. However, the entropy generation rate was found to decrease along the channel through the modules, as the periodic steady conditions were approached in the subsequent modules.
- Open Access
A Combined Optical, Thermal and Electrical Performance Study of a V-Trough PV System—Experimental and Analytical Investigations
The objective of this study was to achieve higher efficiency of a PV system while reducing of the cost of energy generation. Concentration photovoltaics was employed in the present case as it uses low cost reflectors to enhance the efficiency of the PV system and simultaneously reduces the cost of electricity generation. For this purpose a V-trough integrated with the PV system was employed for low concentration photovoltaic (LCPV). Since the electrical output of the concentrating PV system is significantly affected by the temperature of the PV cells, the motivation of the research also included studying the ability to actively cool PV cells to achieve the maximum benefit. The optical, thermal and electrical performance of the V-trough PV system was theoretically modeled and validated with experimental results. Optical modeling of V-trough was carried out to estimate the amount of enhanced absorbed radiation. Due to increase in the absorbed radiation the module temperature was also increased which was predicted by thermal model. Active cooling techniques were studied and the effect of cooling was analyzed on the performance of V-trough PV system. With absorbed radiation and module temperature as input parameters, electrical modeling was carried out and the maximum power was estimated. For the V-trough PV system, experiments were performed for validating the numerical models and very good agreement was found between the two.
Open AccessA Combined Optical, Thermal and Electrical Performance Study of a V-Trough PV System—Experimental and Analytical Investigations
The objective of this study was to achieve higher efficiency of a PV system while reducing of the cost of energy generation. Concentration photovoltaics was employed in the present case as it uses low cost reflectors to enhance the efficiency of the PV system and simultaneously reduces the cost of electricity generation. For this purpose a V-trough integrated with the PV system was employed for low concentration photovoltaic (LCPV). Since the electrical output of the concentrating PV system is significantly affected by the temperature of the PV cells, the motivation of the research also included studying the ability to actively cool PV cells to achieve the maximum benefit. The optical, thermal and electrical performance of the V-trough PV system was theoretically modeled and validated with experimental results. Optical modeling of V-trough was carried out to estimate the amount of enhanced absorbed radiation. Due to increase in the absorbed radiation the module temperature was also increased which was predicted by thermal model. Active cooling techniques were studied and the effect of cooling was analyzed on the performance of V-trough PV system. With absorbed radiation and module temperature as input parameters, electrical modeling was carried out and the maximum power was estimated. For the V-trough PV system, experiments were performed for validating the numerical models and very good agreement was found between the two.
- 13 April 2007
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 51 (9) , 877-898
A Numerical Study of Fluid Flow and Heat Transfer Characteristics in Channels with Staggered Wavy Walls
A two-dimensional steady developing fluid flow and heat transfer through a periodic wavy channel with staggered walls is studied numerically for a fluid with a Prandlt number of 0.7 and compared to flow through the corresponding wavy channel with nonstaggered walls. The lower wall is displaced relative to the upper wall by one-fourth, one-half, and three-fourths of the total one-module length. Sinusoidal and arc-shaped configurations are studied for a fixed set of geometric parameters. Periodically fully developed flow is attained downstream of the first module of the 10 modules considered in this study. Sinusoidal channels with one-half displacement provide lower normalized pressure drop values when compared to all other channels (staggered and nonstaggered) considered in this study. The module average Nusselt number increases monotonically with Reynolds number. Moreover, the heat transfer enhancement ratio for arc-shaped channels with three-fourths displacement is as high as 5.7%.
- 13 April 2007
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 51 (9) , 877-898
A Numerical Study of Fluid Flow and Heat Transfer Characteristics in Channels with Staggered Wavy Walls
A two-dimensional steady developing fluid flow and heat transfer through a periodic wavy channel with staggered walls is studied numerically for a fluid with a Prandlt number of 0.7 and compared to flow through the corresponding wavy channel with nonstaggered walls. The lower wall is displaced relative to the upper wall by one-fourth, one-half, and three-fourths of the total one-module length. Sinusoidal and arc-shaped configurations are studied for a fixed set of geometric parameters. Periodically fully developed flow is attained downstream of the first module of the 10 modules considered in this study. Sinusoidal channels with one-half displacement provide lower normalized pressure drop values when compared to all other channels (staggered and nonstaggered) considered in this study. The module average Nusselt number increases monotonically with Reynolds number. Moreover, the heat transfer enhancement ratio for arc-shaped channels with three-fourths displacement is as high as 5.7%.