Yuji Imafuku
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuji Imafuku has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Yoshida
5 shared publicationsHiroshi Yoshida
3 shared publicationsKyoko Tanaka
3 shared publicationsKeiji Kanemitsu
2 shared publicationsKikuko Kanno
2 shared publicationsKiyoaki Takahashi
Central Clinical Laboratory, Fukushima Medical University School of Medicine, 1-Hikarigaoka, Fukushima 960-1247, Japan
2 shared publications
Latest Publications
- 1 November 2011
- Vol. 59 (11) , 1021-5
[Evaluation of serum iron in hemodialysis patients and its variation due to the difference of blood sampling time].
Diurnal variations in serum iron concentration were examined to investigate the influence of sampling time in hemodialysis (HD) patients and healthy subjects. The serum iron concentration and TIBC of HD patients decreased significantly (p<0.01, p<0.01 respectively) compared to those of healthy subjects. Inversely, the serum ferritin concentration of HD patients increased significantly (p<0.01) compared to that of healthy subjects. These findings show the disturbance of iron transport system: under such condition intracellural iron transition out into peripheral blood stream is low in HD patients. Serum iron concentration in samples collected in the evening decreased significantly both in HD patients (p<0.05) and in healthy subjects (p<0.01). Diurnal variations in serum iron concentration reveal almost similar decrement in both groups. In HD patients, serum iron concentration of the blood samples collected on the third day morning after HD and second day morning after HD was examined to see the influence from changes of circulating plasma volume. The serum iron concentration and Hct value in the second day sampling increased significantly compared to the third day sampling (p<0.01, p<0.01 respectively). In addition, the serum iron concentration corrected by Hct in the second day sampling increased significantly (p<0.01) compared to the third day sampling. We conclude from our results that diurnal variations of serum iron concentration vary in sampling time in HD patients as well as in healthy subjects. We also deduct that there may be other factors concerning changes in circulating plasma volume.
- 1 November 2011
- Vol. 59 (11) , 1021-5
[Evaluation of serum iron in hemodialysis patients and its variation due to the difference of blood sampling time].
Diurnal variations in serum iron concentration were examined to investigate the influence of sampling time in hemodialysis (HD) patients and healthy subjects. The serum iron concentration and TIBC of HD patients decreased significantly (p<0.01, p<0.01 respectively) compared to those of healthy subjects. Inversely, the serum ferritin concentration of HD patients increased significantly (p<0.01) compared to that of healthy subjects. These findings show the disturbance of iron transport system: under such condition intracellural iron transition out into peripheral blood stream is low in HD patients. Serum iron concentration in samples collected in the evening decreased significantly both in HD patients (p<0.05) and in healthy subjects (p<0.01). Diurnal variations in serum iron concentration reveal almost similar decrement in both groups. In HD patients, serum iron concentration of the blood samples collected on the third day morning after HD and second day morning after HD was examined to see the influence from changes of circulating plasma volume. The serum iron concentration and Hct value in the second day sampling increased significantly compared to the third day sampling (p<0.01, p<0.01 respectively). In addition, the serum iron concentration corrected by Hct in the second day sampling increased significantly (p<0.01) compared to the third day sampling. We conclude from our results that diurnal variations of serum iron concentration vary in sampling time in HD patients as well as in healthy subjects. We also deduct that there may be other factors concerning changes in circulating plasma volume.
- 1 December 2010
- Vol. 58 (12) , 1237-44
[Adaptations to the incidental cases encountered at the division of clinical laboratory].
We analyzed 4 cases that were not determined as incidents and another 7 cases determined as incidents, found at the department of clinical laboratory of us from April 2009 to March 2010. The former cases were, excess values of LD, and Cl, and glucose leveled as 0 mg/dl incorrectly, and misdirected blood samples at the ER. Our routine equipment and sample flow did not detect these false values. Resetting for auto dilution system and secondary check by every worker were reconsidered for these measurements. Antiseptic drug usage was notified by clinicians, and actually affected to the excessive Cl value. Real incidents were, two unprocessed samples, leakage of a sample, missing processes that caused delay of clinical practice, mixed up sample labels, a lost narcotic patch during cardiac ultrasonography. A lack of checking, carelessness, and accidental mistakes were reevaluated and reminded for workers on the duties. Also inadequate pharmaceutical knowledge and responsibilities of this section might severely affect on these lessons. Efforts were taken so that all workers shared the accurate information. Code blue cases are defined here as those of life-threatening events and sudden vital changes occurred in highest emergency, involve all health care workers, patients, and families. It is very important here to keep regular trainings for workers to cope with such events as well as preemptive assessments on environment and underlying risks in our laboratory. In line with the continuous advances in clinical medicine, medical safety managements are growing issues. To achieve safer environment and minimize various type of risks in the hospital, these incidents are to be assessed and reported regularly.
- 1 December 2010
- Vol. 58 (12) , 1237-44
[Adaptations to the incidental cases encountered at the division of clinical laboratory].
We analyzed 4 cases that were not determined as incidents and another 7 cases determined as incidents, found at the department of clinical laboratory of us from April 2009 to March 2010. The former cases were, excess values of LD, and Cl, and glucose leveled as 0 mg/dl incorrectly, and misdirected blood samples at the ER. Our routine equipment and sample flow did not detect these false values. Resetting for auto dilution system and secondary check by every worker were reconsidered for these measurements. Antiseptic drug usage was notified by clinicians, and actually affected to the excessive Cl value. Real incidents were, two unprocessed samples, leakage of a sample, missing processes that caused delay of clinical practice, mixed up sample labels, a lost narcotic patch during cardiac ultrasonography. A lack of checking, carelessness, and accidental mistakes were reevaluated and reminded for workers on the duties. Also inadequate pharmaceutical knowledge and responsibilities of this section might severely affect on these lessons. Efforts were taken so that all workers shared the accurate information. Code blue cases are defined here as those of life-threatening events and sudden vital changes occurred in highest emergency, involve all health care workers, patients, and families. It is very important here to keep regular trainings for workers to cope with such events as well as preemptive assessments on environment and underlying risks in our laboratory. In line with the continuous advances in clinical medicine, medical safety managements are growing issues. To achieve safer environment and minimize various type of risks in the hospital, these incidents are to be assessed and reported regularly.
- 1 June 2010
- Vol. 58 (6) , 586-94
[Various troubles in the Central Clinical Laboratory (violence, others) and actions to be taken].
We need to attend to a patient face to face in the physiological function testing room and the central blood-drawing room of the central clinical laboratory in a hospital. Recently, there have been some problems and troubles experienced by medical staff because patients may have had some over-expectations regarding our medical service and their sense of entitlement may have been unrealistic. We report some problems experienced in our Central Clinical Laboratory and hospital, and describe some solutions. If a medical staff member gets into trouble with a patient because of some difference in awareness between him/her and the patient, we should take prompt action regarding these claims and be considerate to the patient. However, we have to take a tough stance against some severe cases, for example violence and intemperate language directed toward medical staff. One of the most important things is to investigate complaints against us, and, through this, keep on improving. Another important thing is to disseminate information among central clinical laboratory teams liaising with nursing and other departments. Therefore, we can establish a good trusting relationship between patients and staff, and consequently our patient service will improve.
- 1 June 2010
- Vol. 58 (6) , 586-94
[Various troubles in the Central Clinical Laboratory (violence, others) and actions to be taken].
We need to attend to a patient face to face in the physiological function testing room and the central blood-drawing room of the central clinical laboratory in a hospital. Recently, there have been some problems and troubles experienced by medical staff because patients may have had some over-expectations regarding our medical service and their sense of entitlement may have been unrealistic. We report some problems experienced in our Central Clinical Laboratory and hospital, and describe some solutions. If a medical staff member gets into trouble with a patient because of some difference in awareness between him/her and the patient, we should take prompt action regarding these claims and be considerate to the patient. However, we have to take a tough stance against some severe cases, for example violence and intemperate language directed toward medical staff. One of the most important things is to investigate complaints against us, and, through this, keep on improving. Another important thing is to disseminate information among central clinical laboratory teams liaising with nursing and other departments. Therefore, we can establish a good trusting relationship between patients and staff, and consequently our patient service will improve.
- 1 November 2008
- Vol. 56 (11) , 955-60
[Induction of PBP2' by antibiotics and disinfectants in MRSE].
Methicilllin-resitant Staphylococcus aureus (MRSA) is still the most important bacterium for hospital infection control, and is known to exhibit beta-lactam resistance. Moreover, the increase in PBP2'-producing methicillin-resistant coagulase-negaive Staphylococcus (MR-CNS), especially methicillin-resistant S. epidermidis (MRSE) has been problematic. In this study, we investigated the induction of PBP2' by MPIPC, other antibiotics and disinfectants in MRSE. The bacterial strains used were MRSE isolated in our clinical laboratory. MRSA-LA 'Seiken' was used for the detection of PBP2'. To investigate induction of PBP2' by MPIPC in MRSE, MRSE was cultured on the medium containing MPIPC at 11 different concentrations from 0.0001 to 6 microg/ml, and PBP2' induction was investigated. Strains in which no induction was noted at a low MPIPC concentration were cultured with other antibiotic discs and discs impregnated with various disinfectants, and PBP2' was detected in colonies that grew around the disc and PBP2' induction was investigated. In the culture on MPIPC-supplemented medium, PBP2' was detected in all strains at 0.01-6 microg/ml. At 0.001 and 0.0001 microg/ml, 8/10 and 4/10 were positive, respectively. Addition of another beta-lactam, particularly cephem antibiotics, induced PBP2' in some strains that were negative at 0.0001 microg/ml. In cultures with disinfectants, inhibition zones were noted, but no PBP2' was induced. PBP2' was induced by a low beta-lactam and was not by disinfectants in MRSE.
- 1 November 2008
- Vol. 56 (11) , 955-60
[Induction of PBP2' by antibiotics and disinfectants in MRSE].
Methicilllin-resitant Staphylococcus aureus (MRSA) is still the most important bacterium for hospital infection control, and is known to exhibit beta-lactam resistance. Moreover, the increase in PBP2'-producing methicillin-resistant coagulase-negaive Staphylococcus (MR-CNS), especially methicillin-resistant S. epidermidis (MRSE) has been problematic. In this study, we investigated the induction of PBP2' by MPIPC, other antibiotics and disinfectants in MRSE. The bacterial strains used were MRSE isolated in our clinical laboratory. MRSA-LA 'Seiken' was used for the detection of PBP2'. To investigate induction of PBP2' by MPIPC in MRSE, MRSE was cultured on the medium containing MPIPC at 11 different concentrations from 0.0001 to 6 microg/ml, and PBP2' induction was investigated. Strains in which no induction was noted at a low MPIPC concentration were cultured with other antibiotic discs and discs impregnated with various disinfectants, and PBP2' was detected in colonies that grew around the disc and PBP2' induction was investigated. In the culture on MPIPC-supplemented medium, PBP2' was detected in all strains at 0.01-6 microg/ml. At 0.001 and 0.0001 microg/ml, 8/10 and 4/10 were positive, respectively. Addition of another beta-lactam, particularly cephem antibiotics, induced PBP2' in some strains that were negative at 0.0001 microg/ml. In cultures with disinfectants, inhibition zones were noted, but no PBP2' was induced. PBP2' was induced by a low beta-lactam and was not by disinfectants in MRSE.
- 1 October 2007
- Vol. 55 (10) , 936-41
[Preanalytical issues].
Preanalytical issues in laboratory medicine have been recognized to be important but not so much effort have been focused to them. Urinalysis is one of the most susceptible examinations to preanalytical issues because urine samples are collected by patients themselves and so is stool examination too. Midstream urine catch is well-known appropriate procedure for many urinalysis. Surface scratching is an appropriate method of stool occult blood testing for colorectal cancer and also strategies to avoid the contact of stool with toilet water is another important technique. We also report a case of abnormal results of creatinine clearance (Ccr) caused by the urine collection apparatus as an example of preanalytical issue.
- 1 October 2007
- Vol. 55 (10) , 936-41
[Preanalytical issues].
Preanalytical issues in laboratory medicine have been recognized to be important but not so much effort have been focused to them. Urinalysis is one of the most susceptible examinations to preanalytical issues because urine samples are collected by patients themselves and so is stool examination too. Midstream urine catch is well-known appropriate procedure for many urinalysis. Surface scratching is an appropriate method of stool occult blood testing for colorectal cancer and also strategies to avoid the contact of stool with toilet water is another important technique. We also report a case of abnormal results of creatinine clearance (Ccr) caused by the urine collection apparatus as an example of preanalytical issue.
- 1 May 2007
- Vol. 55 (5) , 479-82
[Sampling variables in examinees--skin site differences in the measurements of bleeding time and self-monitoring of blood glucose].
Differences in bleeding time and self-monitoring blood glucose (SMBG) level at various skin sites have been scarcely examined in humans. The within-run variation (n=6) of bleeding time in earlobes (Duke's method) ranged from 1 min to 3 min and 30 sec (mean = 1 min and 40 sec), and in day-to-day variation (n= 8), it ranged from 1 min to 3 min (mean = 1 min and 36 sec). Site difference in bleeding time was speculated. In SMBG, firstly, sequential measurement of blood collected from 10 sites in the left forearm was performed, and secondly, comparative measurements of venous blood and blood from finger tips (1-5th), palm (3 sites), forearm (4 sites) and earlobe (1 site) were sequentially performed within 30 min before and after glucose (Trelan-G, 75g) intake. Glucose levels in blood from the fingertips, palm and forearm were generally higher than that of venous blood, and site differences were observed among fingertips, palm and forearm. It was speculated that bleeding time and capillary blood glucose or SMBG level differ among skin sites.
- 1 May 2007
- Vol. 55 (5) , 479-82
[Sampling variables in examinees--skin site differences in the measurements of bleeding time and self-monitoring of blood glucose].
Differences in bleeding time and self-monitoring blood glucose (SMBG) level at various skin sites have been scarcely examined in humans. The within-run variation (n=6) of bleeding time in earlobes (Duke's method) ranged from 1 min to 3 min and 30 sec (mean = 1 min and 40 sec), and in day-to-day variation (n= 8), it ranged from 1 min to 3 min (mean = 1 min and 36 sec). Site difference in bleeding time was speculated. In SMBG, firstly, sequential measurement of blood collected from 10 sites in the left forearm was performed, and secondly, comparative measurements of venous blood and blood from finger tips (1-5th), palm (3 sites), forearm (4 sites) and earlobe (1 site) were sequentially performed within 30 min before and after glucose (Trelan-G, 75g) intake. Glucose levels in blood from the fingertips, palm and forearm were generally higher than that of venous blood, and site differences were observed among fingertips, palm and forearm. It was speculated that bleeding time and capillary blood glucose or SMBG level differ among skin sites.
- 1 August 2006
- Vol. 54 (8) , 853-60
[Standardization and issues of rheumatoid factor measurement].
To disclose the current situation of rheumatoid factor (RF) measurement in Japan. A small-scale survey was performed among members of the committee for the improvement of RF measurement in 2003 using manufacturers' RF reference materials valued based on WHO RF reference and pooled sera. A nationwide questionnaire survey was also performed. Questionnaires were sent to 356 educational institutes certified by the Japan College of Rheumatology in December 2004. The small-scale survey showed inter-laboratory differences of measured RF values, especially using RF references, and less in pooled sera. In the questionnaire survey (187 responses, recovery, 53%), qualitative or semi-quantitative RF measurement methods were used in a small number of institutes and quantitative methods were used in large numbers of institutes, the latex immunoassay (turbidimetric or nepherometric) was predominantly employed. The measuring instruments were various. The upper limit of the reference interval was distributed widely from 5 IU/ml to 40 IU/ml, indicating obvious inter-laboratory differences in RF measurement. Many institutes used the reference intervals recommended by the manufacturers. There are remarkable inter-laboratory differences in RF measurement. Clearly, one of the major issues is the lack of reference materials. We therefore need to establish a reference material of RF, even if it is a temporary one. Scientific societies (Japan College of Rheumatology and Japanese Society of Laboratory Medicine) and manufacturers providing RF measurement reagents should work together for the improvement of RF measurement.
- 1 August 2006
- Vol. 54 (8) , 853-60
[Standardization and issues of rheumatoid factor measurement].
To disclose the current situation of rheumatoid factor (RF) measurement in Japan. A small-scale survey was performed among members of the committee for the improvement of RF measurement in 2003 using manufacturers' RF reference materials valued based on WHO RF reference and pooled sera. A nationwide questionnaire survey was also performed. Questionnaires were sent to 356 educational institutes certified by the Japan College of Rheumatology in December 2004. The small-scale survey showed inter-laboratory differences of measured RF values, especially using RF references, and less in pooled sera. In the questionnaire survey (187 responses, recovery, 53%), qualitative or semi-quantitative RF measurement methods were used in a small number of institutes and quantitative methods were used in large numbers of institutes, the latex immunoassay (turbidimetric or nepherometric) was predominantly employed. The measuring instruments were various. The upper limit of the reference interval was distributed widely from 5 IU/ml to 40 IU/ml, indicating obvious inter-laboratory differences in RF measurement. Many institutes used the reference intervals recommended by the manufacturers. There are remarkable inter-laboratory differences in RF measurement. Clearly, one of the major issues is the lack of reference materials. We therefore need to establish a reference material of RF, even if it is a temporary one. Scientific societies (Japan College of Rheumatology and Japanese Society of Laboratory Medicine) and manufacturers providing RF measurement reagents should work together for the improvement of RF measurement.
- 1 November 2002
- Published by Elsevier in Clinica Chimica Acta
- Vol. 325 (1-2) , 105-111
The effect of EDTA contaminated in sera on laboratory data
- 1 November 2002
- Published by Elsevier in Clinica Chimica Acta
- Vol. 325 (1-2) , 105-111
The effect of EDTA contaminated in sera on laboratory data
- 1 November 2002
- Vol. 50 (11) , 1041-6
[Microbiology--laboratory examinations for bacterias].
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
- 1 November 2002
- Vol. 50 (11) , 1041-6
[Microbiology--laboratory examinations for bacterias].
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
- 1 November 2002
- Published by Elsevier in Clinica Chimica Acta
- Vol. 325 (1-2) , 151-156
Identification of a dysfibrinogenemia of γR275C (Fibrinogen Fukushima)
- 1 November 2002
- Published by Elsevier in Clinica Chimica Acta
- Vol. 325 (1-2) , 151-156
Identification of a dysfibrinogenemia of γR275C (Fibrinogen Fukushima)