Jaume Candell-Riera
Research Subjects
Research Interests
Jaume Candell-Riera has a total of 179 co-authors. Here are the top co-authors by number of shared publications:
- Joan Castell Conesa
Universitary Hospital Vall d'Hebron, Nuclear Medicine Department, Barcelona, Spain
20 shared publications J Soler-Soler
16 shared publicationsJ Castell
10 shared publicationsS Aguadé
10 shared publicationsH García Del Castillo
9 shared publicationsJ Soler Soler
9 shared publications
Latest Publications
- 1 March 2016
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular (English Edition)
- Vol. 35 (2) , 127-128
Motion-perfusion mismatch-pattern on rest-gated SPECT suggests non-transmural necrosis on cardiac magnetic resonance
- 1 March 2016
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular (English Edition)
- Vol. 35 (2) , 127-128
Motion-perfusion mismatch-pattern on rest-gated SPECT suggests non-transmural necrosis on cardiac magnetic resonance
- 1 May 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular (English Edition)
- Vol. 34 (3) , 173-180
SPECT, coronary angio-CT, invasive coronary angiography and fusion images in stable coronary disease
- 1 May 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular (English Edition)
- Vol. 34 (3) , 173-180
SPECT, coronary angio-CT, invasive coronary angiography and fusion images in stable coronary disease
- 1 May 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (3) , 173-180
SPECT, angio-TC coronaria, coronariografía invasiva e imágenes de fusión en la cardiopatía isquémica estable
- 1 May 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (3) , 173-180
SPECT, angio-TC coronaria, coronariografía invasiva e imágenes de fusión en la cardiopatía isquémica estable
- 31 December 2010
- Published by Elsevier in Revista Española de Medicina Nuclear (English Edition)
- Vol. 29 (6) , 299-303
Image fusion of gated SPECT and CT angiography in coronary artery disease. Importance of anatomic-functional correlation
- 31 December 2010
- Published by Elsevier in Revista Española de Medicina Nuclear (English Edition)
- Vol. 29 (6) , 299-303
Image fusion of gated SPECT and CT angiography in coronary artery disease. Importance of anatomic-functional correlation
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S52-52
Gated SPECT abnormalities and risk factors in patients with symptomatic intracranial atherosclerotic stenosis
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S52-52
Gated SPECT abnormalities and risk factors in patients with symptomatic intracranial atherosclerotic stenosis
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S16-16
Intravascular ultrasound and coronary pressure measurements in patients with scintigraphic myocardial ischemia and non-significant coronary lesions
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S16-16
Intravascular ultrasound and coronary pressure measurements in patients with scintigraphic myocardial ischemia and non-significant coronary lesions
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S33
Quantitative gated SPECT interassay reproducibility in atrial fibrillation
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S33
Quantitative gated SPECT interassay reproducibility in atrial fibrillation
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S33
Clinical management of patients with coronary artery disease and reduced left ventricular ejection fraction with and without viability in gated-SPECT
- 30 April 2005
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 12 (2) , S33
Clinical management of patients with coronary artery disease and reduced left ventricular ejection fraction with and without viability in gated-SPECT
- 1 December 2001
- Vol. 42 (12) , 1768-72
Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation.
A high number (30%-50%) of reversible defects have been detected early after coronary balloon angioplasty. Inadequate luminal enlargement despite a good angiographic appearance has been suggested as a possible mechanism of these perfusion abnormalities, and some reports have shown better coronary flow reserve after coronary stent implantation than after balloon dilatation. The primary objective of this study was to evaluate the frequency of early ischemic defects detected by maximal exercise (plus dipyridamole) with (99m)Tc-tetrofosmin SPECT after successful coronary angioplasty with stent implantation. A secondary objective was to determine the prognostic value of these early ischemic defects. Thirty patients without previous myocardial infarction who successfully underwent 1-vessel coronary angioplasty with stent implantation were studied. Maximal-exercise (99m)Tc-tetrofosmin myocardial SPECT, with simultaneous dipyridamole if exercise was suboptimal, was performed at 6 +/- 1 d (mean +/- SD) after percutaneous transluminal coronary angioplasty. At 8 +/- 3 mo, all patients were followed up clinically, and 77% of them underwent follow-up angiography. The percentage of stenosis decreased from 68.5% +/- 12.6% of luminal diameter to 9.3% +/- 8.8% after stent implantation, and minimal luminal diameter increased from 0.89 +/- 0.36 mm to 2.85 +/- 0.45 mm. Mild-to-moderate reversible myocardial defects in the territory of the dilated artery were detected in 5 patients (17%), with no angiographic or procedural differences occurring between them and patients without ischemic defects. At follow-up, the target lesion revascularization rates depending on the presence or absence of early ischemic defects were 40% and 8%, respectively (P = 0.18). Angiographic restenosis occurred in 3 of 4 patients who had early ischemic defects and underwent follow-up angiography and in 3 of 19 patients who had no early ischemic defects and underwent follow-up angiography (restenosis rate, 75% and 16%, respectively; P < 0.05). Coronary angioplasty with stent implantation is associated with a 17% rate of ischemic defects early after the procedure. Patients with early myocardial perfusion defects after coronary stent implantation had a high rate of restenosis.
- 1 December 2001
- Vol. 42 (12) , 1768-72
Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation.
A high number (30%-50%) of reversible defects have been detected early after coronary balloon angioplasty. Inadequate luminal enlargement despite a good angiographic appearance has been suggested as a possible mechanism of these perfusion abnormalities, and some reports have shown better coronary flow reserve after coronary stent implantation than after balloon dilatation. The primary objective of this study was to evaluate the frequency of early ischemic defects detected by maximal exercise (plus dipyridamole) with (99m)Tc-tetrofosmin SPECT after successful coronary angioplasty with stent implantation. A secondary objective was to determine the prognostic value of these early ischemic defects. Thirty patients without previous myocardial infarction who successfully underwent 1-vessel coronary angioplasty with stent implantation were studied. Maximal-exercise (99m)Tc-tetrofosmin myocardial SPECT, with simultaneous dipyridamole if exercise was suboptimal, was performed at 6 +/- 1 d (mean +/- SD) after percutaneous transluminal coronary angioplasty. At 8 +/- 3 mo, all patients were followed up clinically, and 77% of them underwent follow-up angiography. The percentage of stenosis decreased from 68.5% +/- 12.6% of luminal diameter to 9.3% +/- 8.8% after stent implantation, and minimal luminal diameter increased from 0.89 +/- 0.36 mm to 2.85 +/- 0.45 mm. Mild-to-moderate reversible myocardial defects in the territory of the dilated artery were detected in 5 patients (17%), with no angiographic or procedural differences occurring between them and patients without ischemic defects. At follow-up, the target lesion revascularization rates depending on the presence or absence of early ischemic defects were 40% and 8%, respectively (P = 0.18). Angiographic restenosis occurred in 3 of 4 patients who had early ischemic defects and underwent follow-up angiography and in 3 of 19 patients who had no early ischemic defects and underwent follow-up angiography (restenosis rate, 75% and 16%, respectively; P < 0.05). Coronary angioplasty with stent implantation is associated with a 17% rate of ischemic defects early after the procedure. Patients with early myocardial perfusion defects after coronary stent implantation had a high rate of restenosis.