Paul Fazio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Paul Fazio has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jiwu Rao
Centre for Zero Energy Building Studies (CZEBS), Department of Building, Civil and Environmental Engineering, 1455 de Maisonneuve Blvd. West, Montreal, QC, H3G 1M8, Canada
5 shared publications Arslan Alturkistani
2 shared publicationsKaren Bartlett
2 shared publicationsQian Mao
2 shared publications- Amin Hammad
Center for Building Studies, Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, QC, H3G 1M8, Canada
1 shared publication Andreas K. Athienitis
Assoc. Prof., Ctr. for Build. Studies, Concordia Univ., 1455 de Maisonneuve Blvd. West, Montreal, Quebec, Canada
1 shared publication
Latest Publications
- 31 August 2009
- Published by Elsevier in Building and Environment
- Vol. 44 (8) , 1691-1698
Identification and transport investigation of microbial volatile organic compounds in full-scale stud cavities
- 31 August 2009
- Published by Elsevier in Building and Environment
- Vol. 44 (8) , 1691-1698
Identification and transport investigation of microbial volatile organic compounds in full-scale stud cavities
- 31 August 2009
- Published by Elsevier in Building and Environment
- Vol. 44 (8) , 1568-1577
Experimental evaluation of potential transport of mold spores from moldy studs in full-size wall assemblies
- 31 August 2009
- Published by Elsevier in Building and Environment
- Vol. 44 (8) , 1568-1577
Experimental evaluation of potential transport of mold spores from moldy studs in full-size wall assemblies
- 31 December 2008
- Published by Elsevier in Building and Environment
- Vol. 43 (12) , 2203-2215
A new test method to determine the relative drying capacity of building envelope panels of various configurations
- 31 December 2008
- Published by Elsevier in Building and Environment
- Vol. 43 (12) , 2203-2215
A new test method to determine the relative drying capacity of building envelope panels of various configurations
- 1 December 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 13 (4) , 194-204
Test Method to Measure the Relative Capacity of Wall Panels to Evacuate Moisture from Their Stud Cavity
Rainwater penetration is the source of moisture that causes the greatest damage to building envelope assemblies. The building envelope should be designed to reduce the amount of rainwater penetration by deflection and drainage. Since it is not realistic to assume a perfect wall without any leakage, the envelope should have the drying capacity to tolerate defects that may arise from the design, construction, and aging of the exterior wall system. Systems with a greater capacity to evacuate moisture from the stud cavity are less likely to undergo moisture damage. A new testing method is developed and deployed to evaluate the relative drying capacity of six wood-framed wall panels of different configurations built into a test hut and tested within a large scale environmental chamber. The wall panels used plywood, oriented strand board (OSB), or fiberboard as sheathing, but did not include cladding. A uniform moisture source was introduced in a water tray set on a load cell at the bottom of each stud cavity. The protocol is based on the hypothesis that the potential for moving a water molecule from the bottom plate to the exterior of the stud cavity is independent of the previous journey of that molecule, i.e., whether it has traveled from the interior of the bottom plate to the surface of the plate or whether it comes from free water in a tray at the level of the bottom plate. For a given set of boundary conditions, this potential is a function of the characteristics of the wall panel, and is identified as the drying capacity of the panel or its drying by evaporation index (DEI). The value of DEI corresponds to the evaporation rate. The moisture response of wall materials enclosing the stud cavity and the evaporation rate of the moisture source were monitored. The results show that this index can be used as an indicator of the relative drying capacity of different wall systems.
- 1 December 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 13 (4) , 194-204
Test Method to Measure the Relative Capacity of Wall Panels to Evacuate Moisture from Their Stud Cavity
Rainwater penetration is the source of moisture that causes the greatest damage to building envelope assemblies. The building envelope should be designed to reduce the amount of rainwater penetration by deflection and drainage. Since it is not realistic to assume a perfect wall without any leakage, the envelope should have the drying capacity to tolerate defects that may arise from the design, construction, and aging of the exterior wall system. Systems with a greater capacity to evacuate moisture from the stud cavity are less likely to undergo moisture damage. A new testing method is developed and deployed to evaluate the relative drying capacity of six wood-framed wall panels of different configurations built into a test hut and tested within a large scale environmental chamber. The wall panels used plywood, oriented strand board (OSB), or fiberboard as sheathing, but did not include cladding. A uniform moisture source was introduced in a water tray set on a load cell at the bottom of each stud cavity. The protocol is based on the hypothesis that the potential for moving a water molecule from the bottom plate to the exterior of the stud cavity is independent of the previous journey of that molecule, i.e., whether it has traveled from the interior of the bottom plate to the surface of the plate or whether it comes from free water in a tray at the level of the bottom plate. For a given set of boundary conditions, this potential is a function of the characteristics of the wall panel, and is identified as the drying capacity of the panel or its drying by evaporation index (DEI). The value of DEI corresponds to the evaporation rate. The moisture response of wall materials enclosing the stud cavity and the evaporation rate of the moisture source were monitored. The results show that this index can be used as an indicator of the relative drying capacity of different wall systems.
- 23 July 2007
- Published by American Society of Civil Engineers (ASCE)
- p. 256-263
Automated Code Compliance Checking of Building Envelope Performance
The need to satisfy many functional requirements makes building envelope performance assessment difficult. Furthermore, complexity and diversity of building regulations make the understanding of building codes and regulations a complicated task. This paper presents a method for automatically checking building code compliance according to the simulation results of building envelope performance. Firstly, building codes or regulations are represented as a knowledge base using decision tables in XML (Extensible Markup Language). Then, building envelope information is extracted from an IFC (Industry Foundation Classes) digital building model. Simulation programs are used to simulate the functional performance of building envelopes under variable exterior conditions. Finally, a prototype system HAMBE (Heat, Air and Moisture performance of Building Envelope) is developed for automated building code compliance checking. With the aid of this application, the automated building code compliance checking can help architects, engineers and other users query building codes and regulations quickly and efficiently.
- 23 July 2007
- Published by American Society of Civil Engineers (ASCE)
- p. 256-263
Automated Code Compliance Checking of Building Envelope Performance
The need to satisfy many functional requirements makes building envelope performance assessment difficult. Furthermore, complexity and diversity of building regulations make the understanding of building codes and regulations a complicated task. This paper presents a method for automatically checking building code compliance according to the simulation results of building envelope performance. Firstly, building codes or regulations are represented as a knowledge base using decision tables in XML (Extensible Markup Language). Then, building envelope information is extracted from an IFC (Industry Foundation Classes) digital building model. Simulation programs are used to simulate the functional performance of building envelopes under variable exterior conditions. Finally, a prototype system HAMBE (Heat, Air and Moisture performance of Building Envelope) is developed for automated building code compliance checking. With the aid of this application, the automated building code compliance checking can help architects, engineers and other users query building codes and regulations quickly and efficiently.
- 1 June 1997
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 3 (2) , 97-102
Environmental Chamber for Investigation of Building Envelope Performance
This paper describes the design and development of an environmental chamber for investigation of building envelope performance as a function of heat, air, and moisture transfer, and the interaction between the building envelope and the indoor environment. The environmental chamber is the first of its kind in Canada and is unique in concept. It is located in a specially constructed laboratory of the Centre for Building Studies (CBS), in downtown Montreal. Experiments can be performed on envelope assemblies up to 7.2 m high and 4.1 m wide. The environmental chamber consists of two chambers representing dynamic indoor and outdoor conditions, denoted as hot and cold boxes, respectively. Between the hot and cold boxes, a rectangular frame is sandwiched, in which building envelope components can be built up. A metering box is also located on the hot box side of the test specimen to measure heat flow and temperature drop across it for thermal resistance measurement based on the guarded hot box method. Without the metering chamber, the facility can be used for tests similar to the calibrated hot box method. The second major function of the facility is its use as one large environmental chamber for testing full rooms.
- 1 June 1997
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 3 (2) , 97-102
Environmental Chamber for Investigation of Building Envelope Performance
This paper describes the design and development of an environmental chamber for investigation of building envelope performance as a function of heat, air, and moisture transfer, and the interaction between the building envelope and the indoor environment. The environmental chamber is the first of its kind in Canada and is unique in concept. It is located in a specially constructed laboratory of the Centre for Building Studies (CBS), in downtown Montreal. Experiments can be performed on envelope assemblies up to 7.2 m high and 4.1 m wide. The environmental chamber consists of two chambers representing dynamic indoor and outdoor conditions, denoted as hot and cold boxes, respectively. Between the hot and cold boxes, a rectangular frame is sandwiched, in which building envelope components can be built up. A metering box is also located on the hot box side of the test specimen to measure heat flow and temperature drop across it for thermal resistance measurement based on the guarded hot box method. Without the metering chamber, the facility can be used for tests similar to the calibrated hot box method. The second major function of the facility is its use as one large environmental chamber for testing full rooms.