GGGuido Germano

Guido Germano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guido Germano has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Automated quantification of myocardial perfusion using simplified normal limits

    by P.J Slomka, H Nishina, D.S Berman, C Akincioglu, A Abidov, J.D Friedman, S.W Hayes, G Germano


    • 1 November 2001
      • Vol. 42  (11) , 1630-8

    Quantitative analysis of regional motion and thickening by gated myocardial perfusion SPECT: normal heterogeneity and criteria for abnormality.

    by T Sharir, D S Berman, P B Waechter, J Areeda, P B Kavanagh, J Gerlach, X Kang, G Germano

    Quantitation of regional myocardial function is valuable in patients with coronary artery disease. This study assessed normal heterogeneity and developed and validated normal limits for quantitative regional motion and thickening by gated myocardial perfusion SPECT. Patients underwent rest (201)Tl/exercise (99m)Tc-sestamibi gated SPECT. Reference values of motion and thickening for 20 myocardial segments were obtained in 105 patients with <5% likelihood of coronary disease (low-likelihood group). Criteria for abnormality of motion and thickening were defined for each segment, using receiver operator characteristic analysis, in 101 patients with coronary disease (training group). Semiquantitative visual interpretation was used as the gold standard. These criteria were prospectively validated in 100 patients (validation group). Criteria for grading motion and thickening abnormalities by severity levels were also defined and validated. Normal thickening decreased substantially along the longitudinal axis of the left ventricle, from 69% +/- 13% at the apex to 25% +/- 11% at the basal segments, whereas normal motion varied within the same ventricular plane. Validation of the criteria for abnormality yielded high accuracy in the detection of motion abnormalities (sensitivity, 88%; specificity, 92%) and thickening abnormalities (sensitivity, 87%; specificity, 89%). Quantitative motion and thickening segmental scores showed good agreement with visual scores. Normal regional myocardial contraction by gated myocardial perfusion SPECT is characterized by a substantial apex-to-base decline in thickening and by circumferential heterogeneity in endocardial motion. The assignment of segment-specific threshold values for defining motion and thickening abnormalities provided reasonably accurate identification and grading of regional myocardial dysfunction.


    • 1 September 2001
      • Vol. 42  (9) , 1424-36

    Evidence-based risk assessment in noninvasive imaging.

    by L J Shaw, A E Iskandrian, R Hachamovitch, G Germano, H C Lewin, T M Bateman, D S Berman

    Assessment of important clinical and economic outcomes has become central to the evaluation of patient care. Outcome research is deeply rooted in epidemiology, including the use of multivariable, risk-adjusted regression analysis. In our current health care environment, these methods are increasingly being used to assess the quality of care and to profile physicians and laboratories. Nuclear medicine physicians therefore need to better understand outcome methodologies in order to evaluate patient outcomes, develop guidelines, and decide on patient management. This review describes the methods of assessing the diagnostic and prognostic value of nuclear medicine techniques and, briefly, the methodologic limitations of sample size, frequency and type of events, and follow-up periods and the incremental value of imaging. Also described are logistic regression and Cox proportional hazards modeling. Models for risk assessment are designed to identify whether patients require conservative (i.e., low-risk) or aggressive (i.e., high-risk) treatment. Treatment selection is currently based on risk assessment and the formation of an integrated, empiric risk stratification algorithm of care. This review also includes the methods of assessing economic effectiveness and quality-of-life issues for patients examined with nuclear medicine techniques. In this era of constrained resources, low-cost outpatient-based care may be of increasing importance. High-quality evidence of the clinical and economic outcome of nuclear imaging is essential for helping health care providers and payers assess its value.


    • 1 June 2001
      • Vol. 42  (6) , 831-7

    Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction.

    by T Sharir, G Germano, X Kang, H C Lewin, R Miranda, I Cohen, R D Agafitei, J D Friedman, D S Berman

    The combination of myocardial perfusion and poststress ejection fraction (EF) provides incremental prognostic information. This study assessed predictors of nonfatal myocardial infarction (MI) versus cardiac death (CD) by gated myocardial SPECT and examined the value of integrating the amount of ischemia and poststress EF data in risk stratification. We identified 2,686 patients who underwent resting (201)Tl/stress (99m)Tc-sestamibi gated SPECT and were monitored for >1 y. Patients who underwent revascularization < or = 60 d after the nuclear test were censored from the prognostic analysis. Visual scoring of perfusion images used 20 segments and a scale of 0--4. Poststress EF was automatically generated. Cox regression analysis showed that after adjusting for prescan data, the most powerful predictor of CD was poststress EF, whereas the best predictor of MI was the amount of ischemia (summed difference score [SDS]). Integration of the EF and SDS yielded effective stratification of patients into low-, intermediate-, and high-risk subgroups. Patients with EF >50% and a large amount of ischemia were at intermediate risk (2%--3%), whereas those with mild or moderate ischemia were at low risk of CD (4%/y) irrespective of the amount of ischemia. Poststress EF is the best predictor of CD, whereas the amount of ischemia is the best predictor of nonfatal MI. Integration of perfusion and function data improves stratification of patients into low, intermediate, and high risk of CD.


    • 1 May 2001
      • Vol. 42  (5) , 687-94

    Quantitative assessment of motion artifacts and validation of a new motion-correction program for myocardial perfusion SPECT.

    by N Matsumoto, D S Berman, P B Kavanagh, J Gerlach, S W Hayes, H C Lewin, J D Friedman, G Germano

    Patient motion during myocardial perfusion SPECT can produce images that show artifactual perfusion defects. The relationship between the degree of motion and the extent of artifactual perfusion defects is not clear for either single- or double-head detectors. Using both single- and double-head detectors and quantitative perfusion SPECT (QPS) software, we studied the pattern and extent of defects induced by simulated motion and validated a new automatic motion-correction program for myocardial perfusion SPECT. Vertical motion was simulated by upward shifting of the raw projection datasets in a returning pattern (bounce) and in a nonreturning pattern at 3 different phases of the SPECT acquisition (early, middle, and late), whereas upward creep was simulated by uniform shifting throughout the acquisition. Lateral motion was similarly simulated by left shifting of the raw projection datasets in a returning pattern and in a nonreturning pattern. Simulations were performed using single- and double-head detectors, and simulated motion was applied to projection images from 8 patients who had normal 99mTc-sestamibi SPECT findings. Additionally, images from 130 patients with actual clinical motion were assessed before and after motion correction. The extent of perfusion defects was assessed by QPS, and a 20-segment, 5-point scoring system was used to assess the effect of motion on the presence and extent of perfusion defects. Of 12 bounce simulations, the bouncing motion failed to produce significant (>3%) perfusion defects with either the single- or the double-head detector. With the single-head detector, early shifting created the largest defect, whereas with the double-head detector, shifting during the middle of the acquisition created the largest defect. With regard to upward creep, defects were of larger extent with the double- than the single-head detector. With the single-head detector, 8 of 20 simulated motion patterns yielded significant perfusion defects of the left ventricle, 7 (88%) of which were significantly improved after motion correction. With the double-head detector, 12 of 20 patterns yielded significant defects, all of which improved significantly after correction. Of 2,600 segments in the 130 patients with actual clinical motion, only 1.3% (30/2,259) of segments that were considered normal (score = 0 or 1) changed to abnormal (score = 2-4) after motion correction, whereas 27% (92/341) of abnormal segments were reclassified as normal after motion correction. Artifactual perfusion defects created by simulated motion are a function of the time, degree, and type of motion and the number of camera detectors. Application of an automatic motion-correction algorithm effectively decreases motion artifacts on myocardial perfusion SPECT images.


    • 1 July 2000
      • Vol. 41  (7) , 1190-7

    Postexercise lung uptake of 99mTc-sestamibi determined by a new automatic technique: validation and application in detection of severe and extensive coronary artery disease and reduced left ventricular function.

    by C Bacher-Stier, T Sharir, P B Kavanagh, H C Lewin, J D Friedman, R Miranda, G Germano, D S Berman

    This study validated a new automatic algorithm for assessment of lung-to-heart ratio (L/H) of radiotracers in myocardial perfusion SPECT and assessed the diagnostic value of (99m)Tc-sestamibi L/H after exercise. The new technique extracts a left ventricular region of interest (ROI) from a summed anterior projection image and generates a lung ROI by reshaping and translating the left ventricular ROI. This algorithm was applied to 230 patients who underwent exercise (99m)Tc-sestamibi SPECT (gated SPECT, n = 88) with first-pass ventriculography. Normal values were established in 26 patients in whom the likelihood of coronary artery disease (CAD) was 5% or less. An abnormality threshold for detecting severe and extensive CAD was defined in a subgroup of 109 patients who underwent coronary angiography and was validated in a prospective group (n = 72). The success rate of the automatic algorithm was 97%. Excellent correlation was found between automatic and manual L/H values (r = 0.95; P < 0.001). The mean L/H was higher in patients with a peak exercise ejection fraction (EF) less than 40% versus 40% or more (0.51 +/- 0.07 versus 0.43 +/- 0.05, P < 0.001) and in patients with a poststress EF less than 40% versus 40% or more (0.50 +/- 0.07 versus 0.44 +/- 0.06, P < 0.01). A threshold of L/H greater than 0.44 yielded a sensitivity and specificity of 63% and 81%, respectively, for identifying severe and extensive CAD in the prospective group and a sensitivity of 86% in identifying stenosis of 90% or more in the proximal left anterior descending artery. The new automatic algorithm for assessing L/H correlated well with manually derived L/H for (99m)Tc-sestamibi as well as (201)TI SPECT. An increased postexercise (99m)Tc-sestamibi L/H adds significant diagnostic value to study myocardial perfusion SPECT as a marker of severe and extensive CAD and reduced ventricular function.


    • 1 April 2000
      • Vol. 41  (4) , 712-9

    A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility.

    by G Germano, P B Kavanagh, P Waechter, J Areeda, S Van Kriekinge, T Sharir, H C Lewin, D S Berman

    We have developed a new, completely automatic 3-dimensional software approach to quantitative perfusion SPECT. The main features of the software are myocardial sampling based on an ellipsoid model; use of the entire count profile between the endocardial and epicardial surfaces; independence of the algorithm from myocardial shape, size, and orientation and establishment of a standard 3-dimensional point-to-point correspondence among all sampled myocardial regions; automatic generation of quantitative measurements and 5-point semiquantitative scores for each of 20 myocardial segments and automatic derivation of summed perfusion scores; and automatic generation of normal limits for any given patient population on the basis of data fractionally normalized to minimize hot spot artifacts. The new algorithm was tested on the tomographic images of 420 patients studied with a rest 201TI (111-167 MBq, 35 s/projection)-stress 99mTc-sestamibi (925-1480 MBq, 25 s/projection) separate dual-isotope protocol on a single-detector camera, a dual-detector 90 degrees camera, and a triple-detector camera. The algorithm was successful in 397 of 420 patients (94.5%) and 816 of 840 image datasets (97.1%), with a statistically significant difference between the success rates of the 201TI images (399/ 420, or 95.0%) and the 99mTc images (417/420, or 99.3%; P < 0.001). Algorithm failure was caused by extracardiac uptake (10/24, or 41.7%) or inaccurate identification of the valve plane because of low count statistics (14/24, or 58.3%) and was obviated by simply limiting the image volume in which the software operates. Reproducibility of measurements of summed perfusion scores (r = 0.999 and 1 for stress and rest, respectively), global defect extent (r = 0.999 and 1 for stress and rest, respectively), and segmental perfusion scores (exact agreement = 99.9%, kappa = 0.998 for stress and 0.997 for rest) was extremely high. Automatic 3-dimensional quantitation of perfusion from 201Tl and 99mTc-sestamibi images is feasible and reproducible. The described software, because it is based on the same sampling scheme used for gated SPECT analysis, ensures intrinsically perfect registration of quantitative perfusion with quantitative regional wall motion and thickening information, if gated SPECT is used.


    • 1 April 2000
      • Vol. 41  (4) , 720-7

    A new algorithm for the quantitation of myocardial perfusion SPECT. II: validation and diagnostic yield.

    by T Sharir, G Germano, P B Waechter, P B Kavanagh, J S Areeda, J Gerlach, X Kang, H C Lewin, D S Berman

    This study validates a new quantitative perfusion SPECT algorithm for the assessment of myocardial perfusion. The algorithm is not based on slices and provides fully 3-dimensional sampling and analysis independent of assumptions about the geometric shape of the left ventricle. Radiopharmaceutical- and sex-specific normal limits and thresholds for perfusion abnormality in 20 segments of the left ventricle were developed for separate, dual-isotope rest 201Tl-exercise 99mTc-sestamibi SPECT in 36 patients with or =70% stenosis. For the detection of left anterior descending, left circumflex, and right coronary artery stenosis, sensitivity was 84%, 86%, and 88%, respectively, and specificity was 84%, 88%, and 81%, respectively. The new quantitative perfusion SPECT approach is highly sensitive and specific for the detection and localization of CAD, provides accurate automatic scores for the assessment of regional perfusion, and overcomes the low-specificity limitations of previous quantitative algorithms.


    • 1 February 2000
      • p. I31-7

    The clinical value of assessing left ventricular function from gated SPECT perfusion studies.

    by D S Berman, G Germano

    Gated myocardial perfusion SPECT is a technique that is rapidly becoming widespread in the nuclear cardiology arena, and it currently accounts for a majority of all perfusion SPECT acquisitions performed in the USA. Its main advantage is that of providing important incremental clinical information over SPECT perfusion assessment alone, at essentially no extra cost. With respect to the diagnosis of cardiac disease, gated SPECT has been demonstrated to improve specificity by helping identify attenuation artifacts in patients with suspected coronary artery disease, and is also key in identifying patients with non-ischemic cardiomyopathies. In prognostic assessment, gated SPECT-derived measurements of ejection fraction achieve substantial incremental stratification of patients at risk for cardiac death or myocardial infarction, compared to perfusion scores, and volume measurements further improve risk stratification. New quantitative algorithms allow the fast, accurate and reproducible measurement of parameters of global cardiac function (ejection fraction, end-systolic and end-diastolic volume) as well as regional cardiac function (myocardial wall motion and thickening), all of which have been validated against a wide variety of gold standards.