Melvin W. First
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Melvin W. First has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Ashwin S. Dharmadhikari
Division of Pulmonary and Critical Care Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
1 shared publication - David Neil McMurray
Central Tuberculosis Research Institute, Moscow, Russia
1 shared publication Edward A. Nardell
Harvard School of Public Health , Boston, Massachusetts
1 shared publication- Edward A. Nardell
Division of Pulmonary and Critical Care Medicine and Division of Global Health Equity, Brigham &; Women’s Hospital, Harvard Medical School, 7th Floor, FXB Building, 651 Huntington Avenue, Boston, MA, USA 02115
1 shared publication - Ian M. Orme
Mycobacteria Research Laboratories, Department of Microbiology, Immunology and Pathology, Colorado State University, Fort Collins, CO 80523, USA
1 shared publication - Karin Weyer
Global Tuberculosis Programme, World Health Organization, Geneva, Switzerland
1 shared publication
Latest Publications
- 1 July 2011
- Published by Elsevier in Tuberculosis
- Vol. 91 (4) , 329-338
Natural infection of guinea pigs exposed to patients with highly drug-resistant tuberculosis
- 1 July 2011
- Published by Elsevier in Tuberculosis
- Vol. 91 (4) , 329-338
Natural infection of guinea pigs exposed to patients with highly drug-resistant tuberculosis
- 1 January 2007
- Published by Taylor & Francis in LEUKOS
- Vol. 3 (3) , 181-188
Performance of Ultraviolet Germicidal Irradiation Lamps and Luminaires in Long-Term Service
Seven years of experience operating upper-room ultraviolet irradiation systems (UVGI) in 14 homeless shelters in six cities has taught the Tuberculosis Ultraviolet Shelter Study (TUSS) many valuabl...
- 1 January 2007
- Published by Taylor & Francis in LEUKOS
- Vol. 3 (3) , 181-188
Performance of Ultraviolet Germicidal Irradiation Lamps and Luminaires in Long-Term Service
Seven years of experience operating upper-room ultraviolet irradiation systems (UVGI) in 14 homeless shelters in six cities has taught the Tuberculosis Ultraviolet Shelter Study (TUSS) many valuabl...
- 1 May 2005
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 2 (5) , 285-292
Monitoring Human Exposures to Upper-Room Germicidal Ultraviolet Irradiation
After decades of neglect, the resurgence of tuberculosis in the United States between 1985 and 1992 renewed interest in the use of upper room ultraviolet germicidal irradiation to interrupt the transmission of airborne infections. More recently the bioterrorism threat and the appearance of new pathogens with the potential for airborne spread, such as severe acute respiratory syndrome (SARS), have stimulated installations of upper-room irradiation systems. The objective is to flood the entire volume of a room above 6.5 ft with high intensity ultraviolet germicidal irradiation, while minimizing unintentional irradiance below 6.5 ft to avoid eye and skin irritation. Air exchanges between the upper and lower room result in air disinfection of the occupied space. Designers of these systems have adopted the practice of limiting the maximum lower room irradiance at every point to less than the continuous 8-hour time-weighted average threshold limit value, severely limiting the irradiation intensity in the upper room and thereby reducing one of the two major factors determining germicidal effectiveness, the other being room air mixing. The hypothesis of this study is that eye and skin exposure will be well below the recommended safe dose even when maximum eye-level irradiance levels in the room exceed the 8-hour continuous exposure threshold limit. The method employed was to have subjects wear a small photometer that recorded total ultraviolet dose over the period of exposure while subjects went about their normal routine, and comparing this value with a hypothetical dose calculated from the highest measured eye-level irradiance. The results of the study, based on a limited number of observations, confirmed the hypothesis. Observed doses were one-third to a factor of a hundred or more lower than the doses calculated from maximum eye-level irradiances measurements in the occupants' spaces.
- 1 May 2005
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 2 (5) , 285-292
Monitoring Human Exposures to Upper-Room Germicidal Ultraviolet Irradiation
After decades of neglect, the resurgence of tuberculosis in the United States between 1985 and 1992 renewed interest in the use of upper room ultraviolet germicidal irradiation to interrupt the transmission of airborne infections. More recently the bioterrorism threat and the appearance of new pathogens with the potential for airborne spread, such as severe acute respiratory syndrome (SARS), have stimulated installations of upper-room irradiation systems. The objective is to flood the entire volume of a room above 6.5 ft with high intensity ultraviolet germicidal irradiation, while minimizing unintentional irradiance below 6.5 ft to avoid eye and skin irritation. Air exchanges between the upper and lower room result in air disinfection of the occupied space. Designers of these systems have adopted the practice of limiting the maximum lower room irradiance at every point to less than the continuous 8-hour time-weighted average threshold limit value, severely limiting the irradiation intensity in the upper room and thereby reducing one of the two major factors determining germicidal effectiveness, the other being room air mixing. The hypothesis of this study is that eye and skin exposure will be well below the recommended safe dose even when maximum eye-level irradiance levels in the room exceed the 8-hour continuous exposure threshold limit. The method employed was to have subjects wear a small photometer that recorded total ultraviolet dose over the period of exposure while subjects went about their normal routine, and comparing this value with a hypothetical dose calculated from the highest measured eye-level irradiance. The results of the study, based on a limited number of observations, confirmed the hypothesis. Observed doses were one-third to a factor of a hundred or more lower than the doses calculated from maximum eye-level irradiances measurements in the occupants' spaces.
- 1 March 2003
- Published by Taylor & Francis in AIHA Journal
- Vol. 64 (2) , 251-259
Laboratory Chemical Hoods: A Historical Perspective
A historical review of laboratory fume hoods leads to a consideration of the current status of structural design, operating characteristics (with special reference to face velocity), safety (relative to standardized test results), energy conservation, and certification methods. Noteworthy are (1) the increasing complexity of instrumentation designed to assure full safety function plus airflow modulation to minimize energy consumption; (2) the extreme plasticity of accepted and recommended face velocity values; (3) the insensitivity of standardized hood test protocols to variations in face velocity; and (4) a serious lack of correlation between operator risk, face velocity, and standard hood test results. Safety considerations lead to the selection of laboratory fume hoods having the highest demonstrated containment capability. This is in spite of the fact that most hood operations have a low hazard rating. Energy savings could be realized if the face velocity of each hood could be modulated to match the risk associated with the work being conducted.
- 1 March 2003
- Published by Taylor & Francis in AIHA Journal
- Vol. 64 (2) , 251-259
Laboratory Chemical Hoods: A Historical Perspective
A historical review of laboratory fume hoods leads to a consideration of the current status of structural design, operating characteristics (with special reference to face velocity), safety (relative to standardized test results), energy conservation, and certification methods. Noteworthy are (1) the increasing complexity of instrumentation designed to assure full safety function plus airflow modulation to minimize energy consumption; (2) the extreme plasticity of accepted and recommended face velocity values; (3) the insensitivity of standardized hood test protocols to variations in face velocity; and (4) a serious lack of correlation between operator risk, face velocity, and standard hood test results. Safety considerations lead to the selection of laboratory fume hoods having the highest demonstrated containment capability. This is in spite of the fact that most hood operations have a low hazard rating. Energy savings could be realized if the face velocity of each hood could be modulated to match the risk associated with the work being conducted.