Don Minckler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Don Minckler has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Richard A. Hill
2 shared publications- Andrew J. Marshall
Healionics Corporation, Seattle, Washington, USA
1 shared publication - Angela C. Chen
Stein Eye Institute, David Geffen School of Medicine at UCLA, Los Angeles, CA
1 shared publication - Benoit Detry
STAR Medical SA, Avenue Sabin 6, 1300, Wavre, Belgium
1 shared publication Brian Francis
Los Angeles, USA
1 shared publicationDale K. Heuer
Department of Ophthalmology, University of California, College of Medicine, Irvine 92717 USA
1 shared publication
Latest Publications
- Open Access
- 1 December 2020
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 20, 100867
Trans-stromal epithelial cyst after multiple lamellar keratoplasties - Case report and review of literature
- 1 December 2020
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 20, 100867
Open AccessTrans-stromal epithelial cyst after multiple lamellar keratoplasties - Case report and review of literature
- Open Access
- 14 October 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-11
A novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration
Background: A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). Results: In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. Conclusions: The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.
- 14 October 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-11
Open AccessA novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration
Background: A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). Results: In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. Conclusions: The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.
- Open Access
- 18 April 2018
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 12 (1) , 99
A novel method for demonstrating cold agglutinin disease: a case report
Cold agglutinin disease is a rare disorder characterized by an autoimmune hemolytic anemia occurring at low temperatures. Physical examination findings, often limited to acrocyanosis, are combined with a thermal amplitude test to help establish the diagnosis. Thermal amplitude testing determines the highest temperature at which the cold agglutination will occur and is an important parameter in diagnosing cold agglutinin disease. Here we describe a 57-year-old white man of German and Nicaraguan descent with known chronic cold agglutinin disease who presented to our ophthalmology clinic for evaluation of a cataract. During routine cataract surgery, the lowered temperature of the conjunctiva from intermittent flow of balanced salt solution at room temperature induced a cold agglutination reaction in conjunctival vessels easily visible under a surgical microscope. To the best of our knowledge, this method of demonstrating cold agglutinin disease has not been described in the literature and could easily be performed utilizing an ordinary slit lamp. This method could be used as an alternative and rapid screening method for cold agglutinin disease.
- 18 April 2018
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 12 (1) , 99
Open AccessA novel method for demonstrating cold agglutinin disease: a case report
Cold agglutinin disease is a rare disorder characterized by an autoimmune hemolytic anemia occurring at low temperatures. Physical examination findings, often limited to acrocyanosis, are combined with a thermal amplitude test to help establish the diagnosis. Thermal amplitude testing determines the highest temperature at which the cold agglutination will occur and is an important parameter in diagnosing cold agglutinin disease. Here we describe a 57-year-old white man of German and Nicaraguan descent with known chronic cold agglutinin disease who presented to our ophthalmology clinic for evaluation of a cataract. During routine cataract surgery, the lowered temperature of the conjunctiva from intermittent flow of balanced salt solution at room temperature induced a cold agglutination reaction in conjunctival vessels easily visible under a surgical microscope. To the best of our knowledge, this method of demonstrating cold agglutinin disease has not been described in the literature and could easily be performed utilizing an ordinary slit lamp. This method could be used as an alternative and rapid screening method for cold agglutinin disease.
- Open Access
- 1 May 2014
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 132 (5) , 630-632
Clinical and Pathologic Features ofBipolarisEndophthalmitis After Intravitreal Triamcinolone
This article describes the histopathology in 5 eyes, which were from a clinical series of 14 cases of mold-induced endophthalmitis following intravitreal injections of triamcinolone. The organism responsible, Bipolaris hawaiieses, is a rare cause of human ocular infection and its morphology in ocular tissues has not been well described.
- 1 May 2014
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 132 (5) , 630-632
Open AccessClinical and Pathologic Features ofBipolarisEndophthalmitis After Intravitreal Triamcinolone
This article describes the histopathology in 5 eyes, which were from a clinical series of 14 cases of mold-induced endophthalmitis following intravitreal injections of triamcinolone. The organism responsible, Bipolaris hawaiieses, is a rare cause of human ocular infection and its morphology in ocular tissues has not been well described.
- 23 October 2009
- Published by Springer Nature
- p. 301-306
Procedural Treatments: New Surgical Options
- 1 April 2009
- Published by Elsevier in Experimental Eye Research
- Vol. 88 (4) , 792-798
Use of novel devices for control of intraocular pressure
- 1 April 2009
- Published by Elsevier in Experimental Eye Research
- Vol. 88 (4) , 792-798
Use of novel devices for control of intraocular pressure
- 19 April 2006
- Published by Wiley
- No. 2,p. CD004918
Aqueous shunts for glaucoma
Background Aqueous shunts are employed for intraocular pressure (IOP) control in primary and secondary glaucomas that fail medical, laser, and other surgical therapies. Objectives This review compares aqueous shunts for IOP control and safety. Search methods We searched CENTRAL, MEDLINE, PubMed, EMBASE, NRR in January 2006, LILACS to February 2004 and reference lists of included trials. Selection criteria We included all randomized and quasi‐randomized trials in which one arm of the study involved shunts. Data collection and analysis Two authors independently extracted data for included studies and a third adjudicated discrepancies. We contacted investigators for missing information. We used fixed‐effect models and summarized continuous outcomes using mean differences. Main results We included fifteen trials with a total of 1153 participants with mixed diagnoses. Five studies reported details sufficient to verify the method of randomization but only two had adequate allocation concealment. Data collection and follow‐up times were variable. Meta‐analysis of two trials comparing Ahmed implant with trabeculectomy found trabeculectomy resulted in lower mean IOPs 11 to 13 months later (mean difference 3.81 mm Hg, 95% CI 1.94 to 5.69 mm Hg). Meta‐analysis of two trials comparing double‐plate Molteno implant with the Schocket shunt was not done due to substantial heterogeneity. One study comparing ridged with standard double‐plate Molteno implants found no clinically significant differences in outcome. Two trials investigating the effectiveness of adjunctive mitomycin (MMC) with the Molteno and Ahmed implants found no evidence of benefit with MMC. Two trials that investigated surgical technique variations with the Ahmed found no benefit with partial tube ligation or excision of Tenon's capsule. One study concluded there were outcome advantages with a double versus a single‐plate Molteno implant and one trial comparing the 350 mm2 and 500 mm2 Baerveldt shunts found no clinically significant advantage of the larger device but neither of these trials included all patients randomized. One study suggested improved clinical outcome when MMC was employed with a newly described shunt including ultrasound supporting the conclusion. One small study did not demonstrate an outcome advantage to systemic steroid use postoperatively with single‐plate Molteno shunts. One study comparing endocyclophotocoagulation (ECP) with Ahmed implant in complicated glaucomas found no evidence of better IOP control with Ahmed implant over ECP. Authors' conclusions Relatively few randomized trials have been published on aqueous shunts and methodology and data quality among them is poor. To date there is no evidence of superiority of one shunt over another.
- 19 April 2006
- Published by Wiley
- No. 2,p. CD004918
Aqueous shunts for glaucoma
Background Aqueous shunts are employed for intraocular pressure (IOP) control in primary and secondary glaucomas that fail medical, laser, and other surgical therapies. Objectives This review compares aqueous shunts for IOP control and safety. Search methods We searched CENTRAL, MEDLINE, PubMed, EMBASE, NRR in January 2006, LILACS to February 2004 and reference lists of included trials. Selection criteria We included all randomized and quasi‐randomized trials in which one arm of the study involved shunts. Data collection and analysis Two authors independently extracted data for included studies and a third adjudicated discrepancies. We contacted investigators for missing information. We used fixed‐effect models and summarized continuous outcomes using mean differences. Main results We included fifteen trials with a total of 1153 participants with mixed diagnoses. Five studies reported details sufficient to verify the method of randomization but only two had adequate allocation concealment. Data collection and follow‐up times were variable. Meta‐analysis of two trials comparing Ahmed implant with trabeculectomy found trabeculectomy resulted in lower mean IOPs 11 to 13 months later (mean difference 3.81 mm Hg, 95% CI 1.94 to 5.69 mm Hg). Meta‐analysis of two trials comparing double‐plate Molteno implant with the Schocket shunt was not done due to substantial heterogeneity. One study comparing ridged with standard double‐plate Molteno implants found no clinically significant differences in outcome. Two trials investigating the effectiveness of adjunctive mitomycin (MMC) with the Molteno and Ahmed implants found no evidence of benefit with MMC. Two trials that investigated surgical technique variations with the Ahmed found no benefit with partial tube ligation or excision of Tenon's capsule. One study concluded there were outcome advantages with a double versus a single‐plate Molteno implant and one trial comparing the 350 mm2 and 500 mm2 Baerveldt shunts found no clinically significant advantage of the larger device but neither of these trials included all patients randomized. One study suggested improved clinical outcome when MMC was employed with a newly described shunt including ultrasound supporting the conclusion. One small study did not demonstrate an outcome advantage to systemic steroid use postoperatively with single‐plate Molteno shunts. One study comparing endocyclophotocoagulation (ECP) with Ahmed implant in complicated glaucomas found no evidence of better IOP control with Ahmed implant over ECP. Authors' conclusions Relatively few randomized trials have been published on aqueous shunts and methodology and data quality among them is poor. To date there is no evidence of superiority of one shunt over another.
- 1 July 1991
- Published by Elsevier in Ophthalmology
- Vol. 98 (7) , 1083-1086
Apraclonidine Prophylaxis for Postcycloplegic Intraocular Pressure Spikes
- 1 July 1991
- Published by Elsevier in Ophthalmology
- Vol. 98 (7) , 1083-1086
Apraclonidine Prophylaxis for Postcycloplegic Intraocular Pressure Spikes