Thomas Exner
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Exner has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Joyce Low
3 shared publications- David Ewan Connor
St Vincent’s Centre for Applied Medical Research
2 shared publications David Df Ma
1 shared publicationDavid Ma
1 shared publicationF. Mullier
Université Catholique de Louvain, CHU UCL Namur, Namur Thrombosis and Hemostasis Center (NTHC), Namur Institute for Life Sciences (NARILIS), Haematology Laboratory, Yvoir, Belgium
1 shared publicationJ. Favresse
Université Catholique de Louvain, CHU UCL Namur, Namur Thrombosis and Hemostasis Center (NTHC), Namur Institute for Life Sciences (NARILIS), Haematology Laboratory, Yvoir, Belgium
1 shared publication
Latest Publications
- 14 November 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (5) , 690-696
Effect of an activated charcoal product (DOAC Stop™) intended for extracting DOACs on various other APTT-prolonging anticoagulants
Background: The aim of the study was to investigate the specificity of an activated charcoal-based product (DOAC Stop™) initially intended for the specific extraction of direct oral anticoagulants (DOACs) from test plasmas on a range of other anticoagulants. Methods: Test plasmas were prepared by adding various anticoagulants to pooled normal plasma at concentrations prolonging an activated partial thromboplastin time (APTT) test by a factor of 1.5–3. These plasmas were treated with DOAC Stop™ for 5 and 20 min. Then APTTs were repeated and residual anticoagulant concentrations estimated from dose-response curves. Results: The activated charcoal (AC)-based product was found to extract DOACs efficiently. It also bound the intravenous anticoagulants argatroban and lepirudin, but it had no effect on heparin, enoxaparin or danaparoid in plasma. Among other APTT-inhibiting agents that might be present in test plasmas from patients, it extracted protamine, aprotinin and polymyxin. It had no effect on annexin V, thrombomodulin, a typical lupus anticoagulant, a factor VIII antibody, activated protein C or its activator, but it did bind some cationic inhibitors of the APTT with molecular weight below approximately 30 kDa. Conclusions: The AC-based product extracted DOACs efficiently with no effect on heparin-type anticoagulants. It did bind argatroban and hirudin-type anticoagulants, which might occur in plasmas from some inpatients, and APTT results obtained after its use should be interpreted after due consideration of patient medications.
- 14 November 2018
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (5) , 690-696
Effect of an activated charcoal product (DOAC Stop™) intended for extracting DOACs on various other APTT-prolonging anticoagulants
Background: The aim of the study was to investigate the specificity of an activated charcoal-based product (DOAC Stop™) initially intended for the specific extraction of direct oral anticoagulants (DOACs) from test plasmas on a range of other anticoagulants. Methods: Test plasmas were prepared by adding various anticoagulants to pooled normal plasma at concentrations prolonging an activated partial thromboplastin time (APTT) test by a factor of 1.5–3. These plasmas were treated with DOAC Stop™ for 5 and 20 min. Then APTTs were repeated and residual anticoagulant concentrations estimated from dose-response curves. Results: The activated charcoal (AC)-based product was found to extract DOACs efficiently. It also bound the intravenous anticoagulants argatroban and lepirudin, but it had no effect on heparin, enoxaparin or danaparoid in plasma. Among other APTT-inhibiting agents that might be present in test plasmas from patients, it extracted protamine, aprotinin and polymyxin. It had no effect on annexin V, thrombomodulin, a typical lupus anticoagulant, a factor VIII antibody, activated protein C or its activator, but it did bind some cationic inhibitors of the APTT with molecular weight below approximately 30 kDa. Conclusions: The AC-based product extracted DOACs efficiently with no effect on heparin-type anticoagulants. It did bind argatroban and hirudin-type anticoagulants, which might occur in plasmas from some inpatients, and APTT results obtained after its use should be interpreted after due consideration of patient medications.
- 1 March 2018
- Published by Elsevier in Thrombosis Research
- Vol. 163, 117-122
Simple method for removing DOACs from plasma samples
- 1 March 2018
- Published by Elsevier in Thrombosis Research
- Vol. 163, 117-122
Simple method for removing DOACs from plasma samples
- 1 July 2005
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 16 (5) , 375-379
Increased procoagulant phospholipid activity in blood from patients with suspected acute coronary syndromes: a pilot study
Increased platelet activation is well documented in patients with acute coronary syndromes and can be detected by various methods, including flow cytometry and enzyme-linked immunosorbent assay. However, such techniques require several steps and cannot provide quick results. Platelet activation ultimately results in procoagulant phospholipid exposure and we have previously described a simple activated factor X-activated clotting time (XACT) test that is insensitive to resting platelets but that is significantly shortened by activated platelets, microparticles and procoagulant phospholipids. Our aim was to determine whether the XACT test could be used to distinguish patients with chest pain due to cardiac ischaemia from those having chest pain due to non-cardiac causes. We thus carried out XACT tests on ethylenediamine tetraacetic acid whole blood and plasma samples obtained from 46 patients presenting to the emergency department with chest pain and from 30 controls. Sixteen cases (30%) were subsequently diagnosed as acute coronary syndromes. Blood samples from these patients displayed overall significantly shortened XACT results relative to both healthy controls (P < 0.001) and chest pain not due to cardiac ischaemia (P < 0.004). This discrimination was much better with whole blood samples than when platelet-poor plasmas were tested (P = 0.153), suggesting that free microparticles were not the only factors responsible. Thus, the detection of increased procoagulant phospholipid activity in whole blood by shortened XACT results may be a simple and rapid diagnostic marker of some cardiac ischaemic events.
- 1 July 2005
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 16 (5) , 375-379
Increased procoagulant phospholipid activity in blood from patients with suspected acute coronary syndromes: a pilot study
Increased platelet activation is well documented in patients with acute coronary syndromes and can be detected by various methods, including flow cytometry and enzyme-linked immunosorbent assay. However, such techniques require several steps and cannot provide quick results. Platelet activation ultimately results in procoagulant phospholipid exposure and we have previously described a simple activated factor X-activated clotting time (XACT) test that is insensitive to resting platelets but that is significantly shortened by activated platelets, microparticles and procoagulant phospholipids. Our aim was to determine whether the XACT test could be used to distinguish patients with chest pain due to cardiac ischaemia from those having chest pain due to non-cardiac causes. We thus carried out XACT tests on ethylenediamine tetraacetic acid whole blood and plasma samples obtained from 46 patients presenting to the emergency department with chest pain and from 30 controls. Sixteen cases (30%) were subsequently diagnosed as acute coronary syndromes. Blood samples from these patients displayed overall significantly shortened XACT results relative to both healthy controls (P < 0.001) and chest pain not due to cardiac ischaemia (P < 0.004). This discrimination was much better with whole blood samples than when platelet-poor plasmas were tested (P = 0.153), suggesting that free microparticles were not the only factors responsible. Thus, the detection of increased procoagulant phospholipid activity in whole blood by shortened XACT results may be a simple and rapid diagnostic marker of some cardiac ischaemic events.
- 1 January 2004
- Published by Elsevier in Thrombosis Research
- Vol. 114 (5-6) , 547-552
Detection of procoagulant phospholipid interfering in tests for lupus anticoagulant
- 1 January 2004
- Published by Elsevier in Thrombosis Research
- Vol. 114 (5-6) , 547-552
Detection of procoagulant phospholipid interfering in tests for lupus anticoagulant
- 1 December 2003
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 14 (8) , 773-779
A new activated factor X-based clotting method with improved specificity for procoagulant phospholipid
An improved activated factor X-based clotting method was used to investigate activity of procoagulant phospholipid (PPL) in blood samples collected into various anticoagulants and in plasmas with a range of abnormalities. The dilute activated factor X-activated clotting time (XACT) was carried out on a mixture of specimen with phospholipid-free porcine plasma. PPL from the test sample is then rate-limiting, controlling the clotting time so that the XACT is shortened from a maximum of approximately 120 s with citrated platelet-free plasma to approximately 30 s with freeze-thawed platelet-rich plasma. XACT results were only shortened slightly by fresh normal platelet-rich plasma, but were shortened significantly by platelets that had been activated by freeze-thawing. This improved method for PPL was not prolonged by deficiencies of known clotting factors and therapeutic levels of heparin, and it was surprisingly resistant to most lupus anticoagulants. However, it was extremely sensitive to PPL, detecting down to 50 ng/ml synthetic phospholipid added to phospholipid-free plasma. Excellent correlation was achieved between XACT shortening and microparticle count assessed by annexin V-binding and flow cytometry in normal plasma spiked with platelet microparticles. In citrated blood specimens, XACT shortened with time in a temperature-dependent manner. XACT results on blood samples anticoagulated with ethylenediamine tetra-acetate were more stable, and these would be preferable for assessing PPL expression ex vivo. XACT was significantly shorter in whole blood samples than in normal platelet-rich or platelet-poor plasmas, suggesting that PPL was normally expressed more by cells or aggregates larger than platelets or microparticles.
- 1 December 2003
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 14 (8) , 773-779
A new activated factor X-based clotting method with improved specificity for procoagulant phospholipid
An improved activated factor X-based clotting method was used to investigate activity of procoagulant phospholipid (PPL) in blood samples collected into various anticoagulants and in plasmas with a range of abnormalities. The dilute activated factor X-activated clotting time (XACT) was carried out on a mixture of specimen with phospholipid-free porcine plasma. PPL from the test sample is then rate-limiting, controlling the clotting time so that the XACT is shortened from a maximum of approximately 120 s with citrated platelet-free plasma to approximately 30 s with freeze-thawed platelet-rich plasma. XACT results were only shortened slightly by fresh normal platelet-rich plasma, but were shortened significantly by platelets that had been activated by freeze-thawing. This improved method for PPL was not prolonged by deficiencies of known clotting factors and therapeutic levels of heparin, and it was surprisingly resistant to most lupus anticoagulants. However, it was extremely sensitive to PPL, detecting down to 50 ng/ml synthetic phospholipid added to phospholipid-free plasma. Excellent correlation was achieved between XACT shortening and microparticle count assessed by annexin V-binding and flow cytometry in normal plasma spiked with platelet microparticles. In citrated blood specimens, XACT shortened with time in a temperature-dependent manner. XACT results on blood samples anticoagulated with ethylenediamine tetra-acetate were more stable, and these would be preferable for assessing PPL expression ex vivo. XACT was significantly shorter in whole blood samples than in normal platelet-rich or platelet-poor plasmas, suggesting that PPL was normally expressed more by cells or aggregates larger than platelets or microparticles.