Piia von Lode
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Piia von Lode has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Kim Pettersson
2 shared publicationsHarri Takalo
Department of Biotechnology, University of Turku, Tykistökatu 6A, 6th floor, FIN-20520 Turku, Finland, and Innotrac Diagnostics Oy, Kalevantie 25, FIN-20520 Turku, Finland
1 shared publicationJaana Rosenberg
Department of Biotechnology, University of Turku, Tykistökatu 6A, 6th floor, FIN-20520 Turku, Finland, and Innotrac Diagnostics Oy, Kalevantie 25, FIN-20520 Turku, Finland
1 shared publicationJarmo Rainaho
1 shared publicationKari Punnonen
1 shared publicationMia K. Laiho
1 shared publication
Latest Publications
- 31 December 2006
- Published by Elsevier in Thrombosis Research
- Vol. 118 (5) , 573-585
Sensitive and quantitative, 10-min immunofluorometric assay for D-Dimer in whole blood
- 31 December 2006
- Published by Elsevier in Thrombosis Research
- Vol. 118 (5) , 573-585
Sensitive and quantitative, 10-min immunofluorometric assay for D-Dimer in whole blood
- 1 July 2005
- Published by Elsevier in Clinical Biochemistry
- Vol. 38 (7) , 591-606
Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
- 1 July 2005
- Published by Elsevier in Clinical Biochemistry
- Vol. 38 (7) , 591-606
Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
- 28 May 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (13) , 3193-3201
A Europium Chelate for Quantitative Point-of-Care Immunoassays Using Direct Surface Measurement
New labels and assay techniques are needed to improve the sensitivity and quantitativeness of point-of-care immunotesting while sustaining the rapidity and ease of use of the assays. We synthesized a novel, intrinsically fluorescent nonadentate europium chelate with two chromophores and hydrophilic α-galactose side groups. The chelate is highly fluorescent, soluble in water, and provides effective shielding of Eu from water. The performance of the nonadentate chelate was compared with a heptadentate chelate in a dry reagent immunoassay for human chorionic gonadotropin (hCG). After 15-min incubation and washing, time-resolved fluorescence was measured directly from a wet or dried well surface. Contrary to the heptadentate label, the effect of aqueous quenching on the nonadentate label was found to be insignificant, with calculated analytical detection limits (background + 3 SD) of 0.9 and 0.7 IU/L hCG for wet and dry measurements, respectively, and a linear range up to 5000 IU/L. The CVs for the new label were <8% at the cutoff of 25 IU/L and above in both whole blood and plasma. The novel nonadentate label facilitates short turnaround times and simple instrumentation due to the absence of all signal development steps, at the same time retaining an excellent immunoassay performance.
- 28 May 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (13) , 3193-3201
A Europium Chelate for Quantitative Point-of-Care Immunoassays Using Direct Surface Measurement
New labels and assay techniques are needed to improve the sensitivity and quantitativeness of point-of-care immunotesting while sustaining the rapidity and ease of use of the assays. We synthesized a novel, intrinsically fluorescent nonadentate europium chelate with two chromophores and hydrophilic α-galactose side groups. The chelate is highly fluorescent, soluble in water, and provides effective shielding of Eu from water. The performance of the nonadentate chelate was compared with a heptadentate chelate in a dry reagent immunoassay for human chorionic gonadotropin (hCG). After 15-min incubation and washing, time-resolved fluorescence was measured directly from a wet or dried well surface. Contrary to the heptadentate label, the effect of aqueous quenching on the nonadentate label was found to be insignificant, with calculated analytical detection limits (background + 3 SD) of 0.9 and 0.7 IU/L hCG for wet and dry measurements, respectively, and a linear range up to 5000 IU/L. The CVs for the new label were <8% at the cutoff of 25 IU/L and above in both whole blood and plasma. The novel nonadentate label facilitates short turnaround times and simple instrumentation due to the absence of all signal development steps, at the same time retaining an excellent immunoassay performance.