Peter Emil Ochsner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peter Emil Ochsner has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
A. Schweizer
Orthopaedic Department, Kantonsspital Liestal, Rheinstrasse 26, 4410, Liestal, Switzerland
3 shared publicationsU. Riede
Orthopaedic Department, Kantonsspital Liestal, Liestal, Switzerland
3 shared publicationsAndreas Schweizer
1 shared publicationB. Nachbur
1 shared publication- Bernhard Nachbur
Department of Surgery, University of Berne, Talmoosstrasse 48, Ittigen 3063, Switzerland
1 shared publication Christian Plaass
1 shared publication
Latest Publications
- 12 January 2005
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 125 (2) , 80-86
Five-year results of two cemented hip stem models each made of two different alloys
Introduction The aim of this study was to compare the influence of two different cemented hip stems each made of two different alloys concerning survival and outcome. Materials and methods The 5-year results with 161 Mueller straight stems made of cobalt chromium (SS CoCr), 272 Mueller straight stems made of titanium (SS Ti), 233 Mueller SL stems made of titanium (SL Ti) and 255 SL stems made of cobalt chromium (SL CoCr) implanted consecutively in this order were compared. All patients were followed up prospectively during the first 5 years after implantation. The evaluation of the results was retrospective. Results The survival rates for aseptic loosening were 100% (SS CoCr), 92.8% (SS Ti), 81.6% (SL Ti) and 97.8% (SL CoCr). Clinical and radiological outcomes like pain occurrence, use of pain medication, ability to climb stairs, amount of stem subsidence and osteolysis correlated statistically significantly with the results of the survival rates. Concerning the two alloys, chromium cobalt showed better results, and concerning the two designs, the straight stem had a better outcome. For the four prostheses being compared, the results were influenced more by the alloy than by the design, and the small-sized titanium stems were more susceptible to undergoing revision than the large-sized prostheses. Conclusion Stem design and even more alloy may influence the survival rate and clinical outcome. Evaluating the results, we recommend the use of the classic straight stem prosthesis made of cobalt chromium.
- 12 January 2005
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 125 (2) , 80-86
Five-year results of two cemented hip stem models each made of two different alloys
Introduction The aim of this study was to compare the influence of two different cemented hip stems each made of two different alloys concerning survival and outcome. Materials and methods The 5-year results with 161 Mueller straight stems made of cobalt chromium (SS CoCr), 272 Mueller straight stems made of titanium (SS Ti), 233 Mueller SL stems made of titanium (SL Ti) and 255 SL stems made of cobalt chromium (SL CoCr) implanted consecutively in this order were compared. All patients were followed up prospectively during the first 5 years after implantation. The evaluation of the results was retrospective. Results The survival rates for aseptic loosening were 100% (SS CoCr), 92.8% (SS Ti), 81.6% (SL Ti) and 97.8% (SL CoCr). Clinical and radiological outcomes like pain occurrence, use of pain medication, ability to climb stairs, amount of stem subsidence and osteolysis correlated statistically significantly with the results of the survival rates. Concerning the two alloys, chromium cobalt showed better results, and concerning the two designs, the straight stem had a better outcome. For the four prostheses being compared, the results were influenced more by the alloy than by the design, and the small-sized titanium stems were more susceptible to undergoing revision than the large-sized prostheses. Conclusion Stem design and even more alloy may influence the survival rate and clinical outcome. Evaluating the results, we recommend the use of the classic straight stem prosthesis made of cobalt chromium.
- 1 September 2003
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 123 (7) , 353-356
Ten-year follow-up of primary straight-stem prosthesis (MEM) made of titanium or cobalt chromium alloy
- 1 September 2003
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 123 (7) , 353-356
Ten-year follow-up of primary straight-stem prosthesis (MEM) made of titanium or cobalt chromium alloy
- 1 January 2003
- Published by Springer Nature
- p. 229-236
Preoperative Briefing
- 1 January 2003
- Published by Springer Nature
- p. 217-228
Revision Rates Due to Aseptic Loosening After Primary and Revision Procedures
- 1 January 2003
- Published by Springer Nature
- p. 217-228
Revision Rates Due to Aseptic Loosening After Primary and Revision Procedures
- 1 January 2003
- Published by Springer Nature
- p. 203-215
Pain
- 1 January 2003
- Published by Springer Nature
- p. 185-201
Vascular Injuries