Latest Publications
- 1 April 2008
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 27 (4) , 423-426
A Less Invasive Approach to Axial Flow Pump Insertion
- 1 April 2008
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 27 (4) , 423-426
A Less Invasive Approach to Axial Flow Pump Insertion
- 1 January 2008
- Vol. 35 (2) , 184-5
CentriMag left ventricular assist system: cannulation through a right minithoracotomy.
The CentriMag left ventricular assist system can be used for perioperative or postcardiotomy circulatory support of the failing heart. The device resides at the patient's bedside, and the cannulae are usually inserted through a midline sternotomy, with the inflow cannula in the left ventricle or right superior pulmonary vein and the outflow cannula in the aorta. In a patient whose chest has been closed and who has a delayed need for temporary mechanical support, a less invasive method of left ventricular assist device cannula insertion is preferred. In these cases, the CentriMag cannulae can be inserted through a right minithoracotomy with the inflow cannula in the right superior pulmonary vein and the outflow cannula in the aorta, with no heparinization. Herein, we describe this approach in a patient who experienced postcardiotomy cardiogenic shock after aortocoronary bypass surgery. This technique may facilitate ambulation and recovery in selected patients.
- 1 January 2008
- Vol. 35 (2) , 184-5
CentriMag left ventricular assist system: cannulation through a right minithoracotomy.
The CentriMag left ventricular assist system can be used for perioperative or postcardiotomy circulatory support of the failing heart. The device resides at the patient's bedside, and the cannulae are usually inserted through a midline sternotomy, with the inflow cannula in the left ventricle or right superior pulmonary vein and the outflow cannula in the aorta. In a patient whose chest has been closed and who has a delayed need for temporary mechanical support, a less invasive method of left ventricular assist device cannula insertion is preferred. In these cases, the CentriMag cannulae can be inserted through a right minithoracotomy with the inflow cannula in the right superior pulmonary vein and the outflow cannula in the aorta, with no heparinization. Herein, we describe this approach in a patient who experienced postcardiotomy cardiogenic shock after aortocoronary bypass surgery. This technique may facilitate ambulation and recovery in selected patients.
- 30 April 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 83 (4) , 1558-1559
Staged Reoperation: A Novel Strategy for High-Risk Patients
- 30 April 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 83 (4) , 1558-1559
Staged Reoperation: A Novel Strategy for High-Risk Patients
- 30 April 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 83 (4) , 1556-1557
Bedside Right Ventricular Assist Device Removal in the Conscious Patient
- 30 April 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 83 (4) , 1556-1557
Bedside Right Ventricular Assist Device Removal in the Conscious Patient
- 1 January 2007
- Vol. 34 (1) , 19-22
Management of air embolism during HeartMate XVE exchange.
Air embolism is a rare and usually fatal complication of major cardiac surgery. We present a case in which a 45-year-old man supported by a HeartMate(R) XVE left ventricular assist device required a pump exchange due to failure of the device motor. During pump dissection, a massive amount of air entered the systemic circulation. Urgent cannulation for cardiopulmonary bypass was performed, and cardiopulmonary bypass was initiated, followed by profound hypothermia, circulatory arrest, retrograde cerebral perfusion, retrograde coronary sinus perfusion, and then barbiturate coma and steroid therapy. The HeartMate XVE left ventricular assist device was removed, and a HeartMate II was implanted. After 5 days, the patient awoke with left hemiparesis, which nearly resolved with aggressive physical therapy. Forty-four days after the pump exchange operation, the patient was discharged from the hospital with only mild left hemiparesis. Exposure of the left ventricular assist device or its external components requires careful monitoring, because air can enter the pump-particularly in a hypovolemic patient. Rapid response after massive air entry into the left ventricular assist device system, as in our patient, can result in a successful outcome.
- 1 January 2007
- Vol. 34 (1) , 19-22
Management of air embolism during HeartMate XVE exchange.
Air embolism is a rare and usually fatal complication of major cardiac surgery. We present a case in which a 45-year-old man supported by a HeartMate(R) XVE left ventricular assist device required a pump exchange due to failure of the device motor. During pump dissection, a massive amount of air entered the systemic circulation. Urgent cannulation for cardiopulmonary bypass was performed, and cardiopulmonary bypass was initiated, followed by profound hypothermia, circulatory arrest, retrograde cerebral perfusion, retrograde coronary sinus perfusion, and then barbiturate coma and steroid therapy. The HeartMate XVE left ventricular assist device was removed, and a HeartMate II was implanted. After 5 days, the patient awoke with left hemiparesis, which nearly resolved with aggressive physical therapy. Forty-four days after the pump exchange operation, the patient was discharged from the hospital with only mild left hemiparesis. Exposure of the left ventricular assist device or its external components requires careful monitoring, because air can enter the pump-particularly in a hypovolemic patient. Rapid response after massive air entry into the left ventricular assist device system, as in our patient, can result in a successful outcome.
- 1 January 2007
- Vol. 34 (4) , 463-5
Simultaneous insertion of a left ventricular assist system and repair of an ascending aortic dissection.
Operative methods for repairing ascending aortic dissections and for implanting left ventricular assist systems have been thoroughly presented in the medical literature. Only a few reports, however, describe the concomitant performance of these procedures in 1 patient. We report the repair of an acute ascending aortic dissection with simultaneous placement of a long-term left ventricular assist system. One week earlier, the patient had undergone emergent coronary artery bypass grafting and short-term postcardiotomy ventricular assistance when he could not be weaned from cardiopulmonary bypass. By creating a graft-to-graft anastomosis on the bench during cooling of the patient on cardiopulmonary bypass, we were able to shorten to 21 minutes the period of hypothermic circulatory arrest required during ascending aortic dissection repair. The procedures were completed successfully. However, the patient developed pneumonia and sepsis during his extended hospital stay and died of multiorgan failure 5 weeks postoperatively.
- 1 January 2007
- Vol. 34 (4) , 463-5
Simultaneous insertion of a left ventricular assist system and repair of an ascending aortic dissection.
Operative methods for repairing ascending aortic dissections and for implanting left ventricular assist systems have been thoroughly presented in the medical literature. Only a few reports, however, describe the concomitant performance of these procedures in 1 patient. We report the repair of an acute ascending aortic dissection with simultaneous placement of a long-term left ventricular assist system. One week earlier, the patient had undergone emergent coronary artery bypass grafting and short-term postcardiotomy ventricular assistance when he could not be weaned from cardiopulmonary bypass. By creating a graft-to-graft anastomosis on the bench during cooling of the patient on cardiopulmonary bypass, we were able to shorten to 21 minutes the period of hypothermic circulatory arrest required during ascending aortic dissection repair. The procedures were completed successfully. However, the patient developed pneumonia and sepsis during his extended hospital stay and died of multiorgan failure 5 weeks postoperatively.
- 1 January 2005
- Vol. 32 (3) , 434-6
Posttransplant off-pump coronary bypass and laser revascularization in a Jehovah's Witness.
A 57-year-old man, who had received a heart transplant 14 years earlier, underwent coronary artery bypass grafting and transmyocardial laser revascularization for left main, left anterior descending, and circumflex coronary artery disease. The procedures were performed through a left thoracotomy incision without cardiopulmonary bypass. Because the patient was of the Jehovah's Witness faith, no blood or blood products were transfused.
- 1 January 2005
- Vol. 32 (3) , 434-6
Posttransplant off-pump coronary bypass and laser revascularization in a Jehovah's Witness.
A 57-year-old man, who had received a heart transplant 14 years earlier, underwent coronary artery bypass grafting and transmyocardial laser revascularization for left main, left anterior descending, and circumflex coronary artery disease. The procedures were performed through a left thoracotomy incision without cardiopulmonary bypass. Because the patient was of the Jehovah's Witness faith, no blood or blood products were transfused.
- 1 June 2004
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 23 (6) , 759-762
Heartmate vented-electric left ventricular assist system: technique for intrathoracic or intraperitoneal implantation via a left thoracotomy
- 1 June 2004
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 23 (6) , 759-762
Heartmate vented-electric left ventricular assist system: technique for intrathoracic or intraperitoneal implantation via a left thoracotomy
- 1 March 2004
- Vol. 13 (2) , 254-9
Preclinical hemodynamic assessment of a new trileaflet mechanical valve in the aortic position in a bovine model.
The hemodynamic characteristics of a new trileaflet mechanical heart valve (TTV) (TriFlo Inc., Costa Mesa, CA, USA) in the aortic position were evaluated in a bovine model. The TTV was designed to combine the durability of mechanical heart valves with the central flow characteristics of a bioprosthesis. Using nine calves, the native aortic valve was replaced with a 21-mm TTV (n = 6) or a St. Jude Medical (SJM) valve (n = 3). Hemodynamic values were assessed with echocardiography at implantation and with catheterization at explantation. All calves underwent a necropsy, followed by gross pathology and light microscopy studies. The mean implant duration was 159 +/- 55 days for the TTV and 102 +/- 67 days for the SJM valve. Immediately before euthanasia, the peak and mean pressure gradients were respectively 35 +/- 14 and 24 +/- 9 mmHg for the TTV, and 100 +/- 72 and 59 +/- 38 mmHg for the SJM valve (p = 0.03). Two of the SJM-valve animals were electively sacrificed after showing symptoms of aortic stenosis. At necropsy, all nine valves were free from thrombi, pannus, occlusive tissue, or mechanical impairment of leaflet motion. The prematurely sacrificed SJM-valve animals had concentric myocardial hypertrophy consistent with severe functional aortic stenosis. The significantly higher gradients and left ventricular hypertrophy in the SJM-valve animals were related to a smaller effective orifice area, which precluded adaptation to increasing transvalvular volumes in the growing animal. This problem was not seen with the TTV, which performed hemodynamically as well as the SJM valve. The high transvalvular gradients seen with the SJM valve at study end may suggest that the hemodynamic characteristics of the TTV may be superior, though additional studies are needed to confirm this.
- 1 March 2004
- Vol. 13 (2) , 254-9
Preclinical hemodynamic assessment of a new trileaflet mechanical valve in the aortic position in a bovine model.
The hemodynamic characteristics of a new trileaflet mechanical heart valve (TTV) (TriFlo Inc., Costa Mesa, CA, USA) in the aortic position were evaluated in a bovine model. The TTV was designed to combine the durability of mechanical heart valves with the central flow characteristics of a bioprosthesis. Using nine calves, the native aortic valve was replaced with a 21-mm TTV (n = 6) or a St. Jude Medical (SJM) valve (n = 3). Hemodynamic values were assessed with echocardiography at implantation and with catheterization at explantation. All calves underwent a necropsy, followed by gross pathology and light microscopy studies. The mean implant duration was 159 +/- 55 days for the TTV and 102 +/- 67 days for the SJM valve. Immediately before euthanasia, the peak and mean pressure gradients were respectively 35 +/- 14 and 24 +/- 9 mmHg for the TTV, and 100 +/- 72 and 59 +/- 38 mmHg for the SJM valve (p = 0.03). Two of the SJM-valve animals were electively sacrificed after showing symptoms of aortic stenosis. At necropsy, all nine valves were free from thrombi, pannus, occlusive tissue, or mechanical impairment of leaflet motion. The prematurely sacrificed SJM-valve animals had concentric myocardial hypertrophy consistent with severe functional aortic stenosis. The significantly higher gradients and left ventricular hypertrophy in the SJM-valve animals were related to a smaller effective orifice area, which precluded adaptation to increasing transvalvular volumes in the growing animal. This problem was not seen with the TTV, which performed hemodynamically as well as the SJM valve. The high transvalvular gradients seen with the SJM valve at study end may suggest that the hemodynamic characteristics of the TTV may be superior, though additional studies are needed to confirm this.