Yading Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yading Yuan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Hui Li
Department of Radiology, The University of Chicago, 5841 South Maryland Avenue, MC 2026, Chicago, IL 60637
4 shared publications- Maryellen Lissak Giger
The University of Chicago, Department of Radiology, Chicago, Illinois, United States
4 shared publications Charlene Sennett
2 shared publicationsCharlene A. Sennett
Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
1 shared publication- Gillian M. Newstead
Department of Radiology, University of Chicago, Chicago, Illinois
1 shared publication - Kenji Suzuki
Institute of Integrated Research BioMedical Artificial Intelligence (BMAI) Research Unit Institute of Science Tokyo * 226-8503 Kanagawa Japan
1 shared publication
Latest Publications
- 1 September 2010
- Published by Elsevier in Academic Radiology
- Vol. 17 (9) , 1158-1167
Multimodality Computer-Aided Breast Cancer Diagnosis with FFDM and DCE-MRI
- 1 September 2010
- Published by Elsevier in Academic Radiology
- Vol. 17 (9) , 1158-1167
Multimodality Computer-Aided Breast Cancer Diagnosis with FFDM and DCE-MRI
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7260, 72600N-72600
Computerized breast parenchymal analysis on DCE-MRI
Breast density has been shown to be associated with the risk of developing breast cancer, and MRI has been recommended for high-risk women screening, however, it is still unknown how the breast parenchymal enhancement on DCE-MRI is associated with breast density and breast cancer risk. Ninety-two DCE-MRI exams of asymptomatic women with normal MR findings were included in this study. The 3D breast volume was automatically segmented using a volume-growing based algorithm. The extracted breast volume was classified into fibroglandular and fatty regions based on the discriminant analysis method. The parenchymal kinetic curves within the breast fibroglandular region were extracted and categorized by use of fuzzy c-means clustering, and various parenchymal kinetic characteristics were extracted from the most enhancing voxels. Correlation analysis between the computer-extracted percent dense measures and radiologist-noted BIRADS density ratings yielded a correlation coefficient of 0.76 (p<0.0001). From kinetic analyses, 70% (64/92) of most enhancing curves showed persistent curve type and reached peak parenchymal intensity at the last postcontrast time point; with 89% (82/92) of most enhancing curves reaching peak intensity at either 4th or 5th post-contrast time points. Women with dense breast (BIRADS 3 and 4) were found to have more parenchymal enhancement at their peak time point (Ep) with an average Ep of 116.5% while those women with fatty breasts (BIRADS 1 and 2) demonstrated an average Ep of 62.0%. In conclusion, breast parenchymal enhancement may be associated with breast density and may be potential useful as an additional characteristic for assessing breast cancer risk.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7260, 72600N-72600
Computerized breast parenchymal analysis on DCE-MRI
Breast density has been shown to be associated with the risk of developing breast cancer, and MRI has been recommended for high-risk women screening, however, it is still unknown how the breast parenchymal enhancement on DCE-MRI is associated with breast density and breast cancer risk. Ninety-two DCE-MRI exams of asymptomatic women with normal MR findings were included in this study. The 3D breast volume was automatically segmented using a volume-growing based algorithm. The extracted breast volume was classified into fibroglandular and fatty regions based on the discriminant analysis method. The parenchymal kinetic curves within the breast fibroglandular region were extracted and categorized by use of fuzzy c-means clustering, and various parenchymal kinetic characteristics were extracted from the most enhancing voxels. Correlation analysis between the computer-extracted percent dense measures and radiologist-noted BIRADS density ratings yielded a correlation coefficient of 0.76 (p<0.0001). From kinetic analyses, 70% (64/92) of most enhancing curves showed persistent curve type and reached peak parenchymal intensity at the last postcontrast time point; with 89% (82/92) of most enhancing curves reaching peak intensity at either 4th or 5th post-contrast time points. Women with dense breast (BIRADS 3 and 4) were found to have more parenchymal enhancement at their peak time point (Ep) with an average Ep of 116.5% while those women with fatty breasts (BIRADS 1 and 2) demonstrated an average Ep of 62.0%. In conclusion, breast parenchymal enhancement may be associated with breast density and may be potential useful as an additional characteristic for assessing breast cancer risk.
- 13 November 2008
- Published by Wiley in Medical Physics
- Vol. 35 (12) , 5490-5500
Correlative feature analysis on FFDM
Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer‐aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual‐stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two‐step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, thedistancefeature yielded an area under the ROC curve (AUC) ofwith leave‐one‐out (by physical lesion) evaluation, and the feature metric subset, which includeddistance, gradient texture, and ROI‐basedcorrelation, yielded an AUC of. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.
- 13 November 2008
- Published by Wiley in Medical Physics
- Vol. 35 (12) , 5490-5500
Correlative feature analysis on FFDM
Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer‐aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual‐stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two‐step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, thedistancefeature yielded an area under the ROC curve (AUC) ofwith leave‐one‐out (by physical lesion) evaluation, and the feature metric subset, which includeddistance, gradient texture, and ROI‐basedcorrelation, yielded an AUC of. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.
- 15 October 2007
- Published by Wiley in Medical Physics
- Vol. 34 (11) , 4180-4193
A dual‐stage method for lesion segmentation on digital mammograms
Mass lesion segmentation on mammograms is a challenging task since mass lesions are usually embedded and hidden in varying densities of parenchymal tissue structures. In this article, we present a method for automatic delineation of lesion boundaries on digital mammograms. This method utilizes a geometric active contour model that minimizes an energy function based on the homogeneities inside and outside of the evolving contour. Prior to the application of the active contour model, a radial gradient index (RGI)-based segmentation method is applied to yield an initial contour closer to the lesion boundary location in a computationally efficient manner. Based on the initial segmentation, an automatic background estimation method is applied to identify the effective circumstance of the lesion, and a dynamic stopping criterion is implemented to terminate the contour evolution when it reaches the lesion boundary. By using a full-field digital mammography database with 739 images, we quantitatively compare the proposed algorithm with a conventional region-growing method and an RGI-based algorithm by use of the area overlap ratio between computer segmentation and manual segmentation by an expert radiologist. At an overlap threshold of 0.4, 85% of the images are correctly segmented with the proposed method, while only 69% and 73% of the images are correctly delineated by our previous developed region-growing and RGI methods, respectively. This resulting improvement in segmentation is statistically significant.
- 15 October 2007
- Published by Wiley in Medical Physics
- Vol. 34 (11) , 4180-4193
A dual‐stage method for lesion segmentation on digital mammograms
Mass lesion segmentation on mammograms is a challenging task since mass lesions are usually embedded and hidden in varying densities of parenchymal tissue structures. In this article, we present a method for automatic delineation of lesion boundaries on digital mammograms. This method utilizes a geometric active contour model that minimizes an energy function based on the homogeneities inside and outside of the evolving contour. Prior to the application of the active contour model, a radial gradient index (RGI)-based segmentation method is applied to yield an initial contour closer to the lesion boundary location in a computationally efficient manner. Based on the initial segmentation, an automatic background estimation method is applied to identify the effective circumstance of the lesion, and a dynamic stopping criterion is implemented to terminate the contour evolution when it reaches the lesion boundary. By using a full-field digital mammography database with 739 images, we quantitatively compare the proposed algorithm with a conventional region-growing method and an RGI-based algorithm by use of the area overlap ratio between computer segmentation and manual segmentation by an expert radiologist. At an overlap threshold of 0.4, 85% of the images are correctly segmented with the proposed method, while only 69% and 73% of the images are correctly delineated by our previous developed region-growing and RGI methods, respectively. This resulting improvement in segmentation is statistically significant.