DTDomenico Tigani

Domenico Tigani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Domenico Tigani has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison between two computer‐assisted total knee arthroplasty: gap‐balancing versus measured resection technique

    by Domenico Tigani, G. Sabbioni, R. Ben Ayad, M. Filanti, N. Rani, N. Del Piccolo

    Two surgical strategies are possible in total knee arthroplasty (TKA): a measured resection technique, in which bone landmarks are used to guide resections equal to the distal and posterior thickness of the femoral component, or a gap‐balancing approach, in which equal collateral ligament tension in flexion and extension is sought before and as a guide to final bone cuts. In this study performed with computer assisted system, we compared the 2 different methods in 126 patients followed prospectively in order to analyze the effect of both the techniques on joint‐line (JL) maintenance, axial limb restoration and components position. The gap technique showed a statistical increase in the post‐operative value when compared with the measured resection technique, (P = 0.008). When comparing the two groups regarding to the pre‐operative deformity, we have found a statistical difference (P = 0.001) in case of moderate pre‐operative deformity (less than 10°), and the measured resection technique showed a slight superiority in preserving a joint line more faithful to the pre‐operative. We found an ideal alignment for the mechanical axis (180° ± 3°) (95% of cases). In six cases (5%), the mean post‐operative value exceeded (varus or valgus) the ideal value by more than 3°. In the frontal plane, a good alignment was observed for both femoral and tibial components without a significant difference between the two techniques. In the sagittal plane was found more alignment variability due to the different implants used and their ideal starting slope, from 7° to 3°. Finally, the surgeon can use the approach with which he has more confidence; however, as the measured resection technique causes less reduction in the post‐operative joint‐line position, in case of shortening of patellar tendon or patella infera, this technique is preferable.


  • Total knee arthroplasty in patients with poliomyelitis

    by D. Tigani, M. Fosco, L. Amendola, L. Boriani


  • Early aseptic loosening of a porous tantalum knee prosthesis

    by D. Tigani, G. Sabbioni, A. Raimondi

    Porous tantalum represents a relatively new solution for primary and revision total knee arthroplasty, offering several unmatched properties. Tantalum is a transition metal, with excellent biocompatibility and bioactivity due to its intrinsic physical and structural characteristics. A widespread clinical use of porous tantalum tibial components for primary total knee arthroplasty has been partly hindered by the difficulty in removing this type of implant after bone in growth, often leading to a significant bone defect. On the contrary, in the case here reported, removal of the trabecular metal tibial component was unexpectedly easy at a 7-month follow-up due to the absence of bone ingrowth but with a complete preservation of the tibial plate bone stock. Causes for the lack of bone ingrowth are discussed.


  • Preliminary experience with electromagnetic navigation system in TKA

    by D. Tigani, M. Busacca, A. Moio, E. Rimondi, N. Del Piccolo, G. Sabbioni


  • Trabecular metal patella in total knee arthroplasty with patella bone deficiency

    by D. Tigani, P. Trentani, F. Trentani, I. Andreoli, G. Sabbioni, N. Del Piccolo


  • Interlocking nail for femoral shaft fractures: is dynamization always necessary?

    by D. Tigani, M. Fravisini, C. Stagni, R. Pascarella, S. Boriani

    A series of 179 closed femoral fractures treated by static interlocking nailing (Grosse-Kempf nail) was reviewed to evaluate the effect of dynamization on the time to bony union. In 75 patients, dynamization was performed whereas in 104 the implant was left static. Union occurred in 178 patients. We observed one infection. Time to union was significantly shorter in the static group (103 days) compared to the dynamized group (126 days).


    • 24 September 2004
      • Vol. 89  (1) , 29-33

    The treatment of bone defects in primary arthroplasty of the knee.

    by D Tigani, P Trentani, F Trentani, A Marinelli, G Bianchi, M Fravisini

    The authors reviewed the literature as well as their own cases in order to discuss the indications, advantages and disadvantages relative to the methods used to treat bone defects in primary knee arthroplasty. An analysis shows that the use of cement represents the most unfavorable method from a mechanical point of view and it should thus be limited to defects that are not too deep and extensive. Bone grafts, both homoplastic and autoplastic, are preferred in younger patients. The former in lesions that are smaller, the latter in those that are larger. Currently, modular prostheses are diffusedly used because of their versatility and relatively low cost if we compare them with prostheses that are custom made. Finally, the authors emphasize the need to use intramedullary stems in bone defect with the purpose of reducing stress in the metaphyseal region.

    • 2 January 2003
      • Vol. 87  (2) , 117-24

    Conjoined fracture-dislocation of the forearm at the elbow.

    by R Pascarella, D Tigani, P Bungaro, L Ponziani, E Gozzi, Stefano Boriani

    Conjoined fracture-dislocation of the elbow were first described by Marotte in 1982. In this study, a total of 41 patients treated between 1975 and 1995 at the Rizzoli Orthopaedic Institute and 4 patients treated between 1997 and 2000 at the Division of Orthopaedics at the Maggiore Hospital are evaluated. Based on the Marotte classification, the patients are divided into 4 groups, by site of dislocation of the radial capitellum and amount of comminution of the fracture of the ulna. A clinical and radiographic evaluation was made after a mean follow-up of 5.3 years based on Anderson criteria. The results obtained were excellent in 17 patients (37.8%) satisfactory in 13 (28.9%), dissatisfactory in 12 (26.7%); 3 patients were considered to be failures (6.7%), the best results were obtained in type I anterior dislocations.

  • Closed-Wedge Tibial Osteotomy: Conventional Technique Versus a New System of Compression-Dynamic Fixation

    by D Tigani, A Del Baldo, P Trentani, F Trentani, A Marinelli, G Bianchi

    Two groups of patients treated with different techniques of closed wedge tibial osteotomy were analyzed. Twenty-eight patients underwent the conventional technique and 31 patients underwent a closed-wedge osteotomy using a new osteotomy cutting jig and compression-dynamic fixation. The groups were comparable with respect to age, gender, and deformity. Using the conventional technique, only 68% of knees had an optimal postoperative femorotibial angle between 167 degrees and 175 degrees, compared to 88% using the new device (P=.02). High tibial osteotomy with an osteotomy jig provides a more accurate correction of deformity than the conventional technique.


    • 25 May 2002
      • Vol. 86  (3) , 183-90

    Intramedullary osteosynthesis after external fixation.

    by S Paderni, P Trentani, G Grippo, G Bianchi, P B Squarzina, D Tigani

    The authors report the results of a retrospective study conducted on 30 cases of fracture of the tibia and femur submitted to external fixation and subsequently to intramedullary osteosynthesis, treated between 1991 and 1999. Intramedullary osteosynthesis was used in 24 cases (5 in the femur and 19 in the tibia) as treatment subsequent to external fixation for nonunion or delays in consolidation. Sequential nailing was used as planned treatment in the remaining 6 cases. In 83.3% of cases the fracture was open (Gustilo Anderson type I (30%), type II (20%), type III (33.3%). The mean duration of external fixation was 13.24 weeks, and infection occurred in 4 cases (13.33%) during that time. Removal of the external fixator and intramedullary osteosynthesis were carried out during the same surgical session in 40% of the cases, while nailing was preceded by a period in plaster lasting an average of 4 weeks in the remaining 60% of cases. All of the cases achieved consolidation an average of 31 weeks after trauma, and 14.7 weeks after intramedullary synthesis. We observed the occurrence of infection in 3 cases (10%), but this did not keep consolidation from occurring.