Marcus-Matthias Gellrich
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marcus-Matthias Gellrich has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
C. Kandzia
Orth- und Pleoptik, Uni Augenklinik Kiel, Kiel, Deutschland
1 shared publicationKarsten Hufendiek
Universitätsklinik für Augenheilkunde der Medizinischen Hochschule Hannover, Hannover, Deutschland
1 shared publication- Majeed Rana
Department of Oral and Maxillofacial Surgery, University Hospital Ulm, 89081 Ulm, Germany
1 shared publication - Nils-Claudius Gellrich
Department of Oral and Maxillofacial Surgery, Hannover Medical School, Hannover, Germany
1 shared publication
Latest Publications
- 17 April 2023
- Published by Springer Nature in Die Ophthalmologie
- Vol. 120 (6) , 667-672
Einfache Fundusperimetrie mit der Spaltlampe
Zusammenfassung Es wird ein Verfahren zur direkten Fundusperimetrie an der Spaltlampe durch eine hochbrechende Konvexlinse (+ 90 D) beschrieben. Als Lichtmarke wird am vorhandenen Blendensystem eine Zwischenrast in Form einer doppelten Halbkreisblende eingestellt. Insbesondere bei Hemianopsien kommt man in der klinischen Anwendung zu schnellen Ergebnissen bei geringer Belastung für den Patienten. Durch planvolle Änderungen im Blendensystem der Spaltlampe ließe sich die Anwendung des gezeigten Verfahrens noch deutlich verfeinern und erweitern.
- 17 April 2023
- Published by Springer Nature in Die Ophthalmologie
- Vol. 120 (6) , 667-672
Einfache Fundusperimetrie mit der Spaltlampe
Zusammenfassung Es wird ein Verfahren zur direkten Fundusperimetrie an der Spaltlampe durch eine hochbrechende Konvexlinse (+ 90 D) beschrieben. Als Lichtmarke wird am vorhandenen Blendensystem eine Zwischenrast in Form einer doppelten Halbkreisblende eingestellt. Insbesondere bei Hemianopsien kommt man in der klinischen Anwendung zu schnellen Ergebnissen bei geringer Belastung für den Patienten. Durch planvolle Änderungen im Blendensystem der Spaltlampe ließe sich die Anwendung des gezeigten Verfahrens noch deutlich verfeinern und erweitern.
- 15 May 2020
- Published by Springer Nature in Der Ophthalmologe
- Vol. 118 (2) , 162-168
Pachymetrie mit einer Videospaltlampe
Background and objective Presentation and application of a method for pachymetry with the slit lamp based on the concept of a defined optical section. Methods and patients The visible width of an optical section on slit lamp examination with a 45 degrees angle between the slit beam and the central corneal surface was determined in 103 eyes (68 with glaucoma and 35 in patients with keratoconus). The measurements were compared to the pachymetric values previously determined elsewhere for these eyes in order to establish a proportionality factor for calculation of corneal thickness from slit lamp measurements. Results From a linear regression between the external pachymetry and visible width of the optical section in the split lamp, 1.71 was determined to be the factor of proportionality. Applying this factor to single measurements, 82 out of 103 eyes had a maximum difference of 40 & x202f;mu m compared to the external pachymetric values. Conclusion Based on a defined optical section at the slit lamp, clinically relevant estimates can be made for central corneal thickness in diseases, such as glaucoma or keratoconus. The difference to the externally measured pachymetric values was within the range of diurnal changes in corneal thickness for 80% of the eyes. Similar to other pachymetric procedures, the reliability of determination of the corneal thickness with the slit lamp also increases when applied intraindividually or for the same eye in the course of time.
- 15 May 2020
- Published by Springer Nature in Der Ophthalmologe
- Vol. 118 (2) , 162-168
Pachymetrie mit einer Videospaltlampe
Background and objective Presentation and application of a method for pachymetry with the slit lamp based on the concept of a defined optical section. Methods and patients The visible width of an optical section on slit lamp examination with a 45 degrees angle between the slit beam and the central corneal surface was determined in 103 eyes (68 with glaucoma and 35 in patients with keratoconus). The measurements were compared to the pachymetric values previously determined elsewhere for these eyes in order to establish a proportionality factor for calculation of corneal thickness from slit lamp measurements. Results From a linear regression between the external pachymetry and visible width of the optical section in the split lamp, 1.71 was determined to be the factor of proportionality. Applying this factor to single measurements, 82 out of 103 eyes had a maximum difference of 40 & x202f;mu m compared to the external pachymetric values. Conclusion Based on a defined optical section at the slit lamp, clinically relevant estimates can be made for central corneal thickness in diseases, such as glaucoma or keratoconus. The difference to the externally measured pachymetric values was within the range of diurnal changes in corneal thickness for 80% of the eyes. Similar to other pachymetric procedures, the reliability of determination of the corneal thickness with the slit lamp also increases when applied intraindividually or for the same eye in the course of time.
- 8 November 2018
- Published by Wiley in Acta Ophthalmologica
- Vol. 97 (4) , E666-E667
The tick sign – a new and simple test to diagnose keratoconus at the slit lamp
- 8 November 2018
- Published by Wiley in Acta Ophthalmologica
- Vol. 97 (4) , E666-E667
The tick sign – a new and simple test to diagnose keratoconus at the slit lamp
- 13 July 2018
- Published by Springer Nature in Der Ophthalmologe
- Vol. 115 (10) , 885-892
Die Spaltlampe als Videografiekonsole
Heute verfügbare Spaltlampen sind für das Prinzip der fokalen Beleuchtung optimiert. Für die klinische Arbeit resultiert eine praktisch intuitive Bedienung der Spaltlampe. Allerdings verzichtet man durch das starre Bauprinzip auf weitergehende Anwendungen, die im vorliegenden Film (online verfügbar) erstmals zusammenfassend vorgestellt werden.
- 13 July 2018
- Published by Springer Nature in Der Ophthalmologe
- Vol. 115 (10) , 885-892
Die Spaltlampe als Videografiekonsole
Heute verfügbare Spaltlampen sind für das Prinzip der fokalen Beleuchtung optimiert. Für die klinische Arbeit resultiert eine praktisch intuitive Bedienung der Spaltlampe. Allerdings verzichtet man durch das starre Bauprinzip auf weitergehende Anwendungen, die im vorliegenden Film (online verfügbar) erstmals zusammenfassend vorgestellt werden.
- 24 August 2016
- Published by Springer Nature in Der Ophthalmologe
- Vol. 113 (9) , 789-793
Purkinje-Bilder in der Spaltlampenvideographie
Spiegelreflexe werden üblicherweise während der Spaltlampenuntersuchung eher als störend empfunden und „ausgeblendet“. In diesem Video, das online zur Verfügung steht, werden gemäß unserem Konzept der Spaltlampenvideographie klinische Informationen analysiert, die in den Purkinje-Bildern enthalten sind. Zunächst werden die 4 Purkinje-Reflexe im phaken Auge vorgestellt, die an den 4 optischen Grenzflächen des Auges entstehen (jeweils Vorder- und Rückseite von Hornhaut und Linse). Dies geschieht in einem fiktiven Diskurs zwischen der Spaltlampe und deren Nutzer M.-M. Im pseudophaken Auge bietet die Kunstlinse 2 neue optische Grenzflächen mit herausragenden spiegeloptischen Eigenschaften. So können bei geeigneter Untersuchungstechnik im Bereich des Spiegelbezirks des dritten Purkinje-Reflexes Veränderungen des vorderen Augensegmentes kontrastreich dargestellt werden. Die Größe des dritten und vierten Purkinje-Bildes unterliegt einerseits den Gesetzen der Spiegeloptik und wird von der Krümmung der brechenden Flächen der Intraokularlinse bestimmt, andererseits erfährt das dritte Purkinje-Bild eine erhebliche Zusatzvergrößerung wegen seiner Lokalisation tief im Glaskörper, da das Auge des Patienten selbst wiederum als Lupe wirkt. Auf diesem Hintergrund kann man „refraktive Aussagen“ über die Stärke von implantierten Intraokularlinsen machen. Dies gipfelt darin, dass man mit einer Videospaltlampe intraindividuell meistens einen Brechkraftunterschied von 0,5 dpt erkennen kann – vorausgesetzt der gleiche Intraokularlinsentyp wurde implantiert. Ein historischer Abstecher in die „pränatale Phase“ der Spaltlampe nach Uppsala zeigt, dass das wichtigste Untersuchungsgerät des Augenarztes seine Ursprünge in der katoptrischen (spiegeloptischen) Nutzung hat: A. Gullstrand sprach von einer ophthalmometrischen Nernstlampe.
- 24 August 2016
- Published by Springer Nature in Der Ophthalmologe
- Vol. 113 (9) , 789-793
Purkinje-Bilder in der Spaltlampenvideographie
Spiegelreflexe werden üblicherweise während der Spaltlampenuntersuchung eher als störend empfunden und „ausgeblendet“. In diesem Video, das online zur Verfügung steht, werden gemäß unserem Konzept der Spaltlampenvideographie klinische Informationen analysiert, die in den Purkinje-Bildern enthalten sind. Zunächst werden die 4 Purkinje-Reflexe im phaken Auge vorgestellt, die an den 4 optischen Grenzflächen des Auges entstehen (jeweils Vorder- und Rückseite von Hornhaut und Linse). Dies geschieht in einem fiktiven Diskurs zwischen der Spaltlampe und deren Nutzer M.-M. Im pseudophaken Auge bietet die Kunstlinse 2 neue optische Grenzflächen mit herausragenden spiegeloptischen Eigenschaften. So können bei geeigneter Untersuchungstechnik im Bereich des Spiegelbezirks des dritten Purkinje-Reflexes Veränderungen des vorderen Augensegmentes kontrastreich dargestellt werden. Die Größe des dritten und vierten Purkinje-Bildes unterliegt einerseits den Gesetzen der Spiegeloptik und wird von der Krümmung der brechenden Flächen der Intraokularlinse bestimmt, andererseits erfährt das dritte Purkinje-Bild eine erhebliche Zusatzvergrößerung wegen seiner Lokalisation tief im Glaskörper, da das Auge des Patienten selbst wiederum als Lupe wirkt. Auf diesem Hintergrund kann man „refraktive Aussagen“ über die Stärke von implantierten Intraokularlinsen machen. Dies gipfelt darin, dass man mit einer Videospaltlampe intraindividuell meistens einen Brechkraftunterschied von 0,5 dpt erkennen kann – vorausgesetzt der gleiche Intraokularlinsentyp wurde implantiert. Ein historischer Abstecher in die „pränatale Phase“ der Spaltlampe nach Uppsala zeigt, dass das wichtigste Untersuchungsgerät des Augenarztes seine Ursprünge in der katoptrischen (spiegeloptischen) Nutzung hat: A. Gullstrand sprach von einer ophthalmometrischen Nernstlampe.
- 15 February 2016
- Published by Springer Nature in International Ophthalmology
- Vol. 36 (6) , 775-780
A simple method for panretinal imaging with the slit lamp
Slit lamp biomicroscopy of the retina with a convex lens is a key procedure in clinical practice. The methods presented enable ophthalmologists to adequately image large and peripheral parts of the fundus using a video-slit lamp and freely available stitching software. A routine examination of the fundus with a slit lamp and a +90 D lens is recorded on a video film. Later, sufficiently sharp still images are identified on the video sequence. These still images are imported into a freely available image-processing program (Hugin, for stitching mosaics together digitally) and corresponding points are marked on adjacent still images with some overlap. Using the digital stitching program Hugin panoramic overviews of the retina can be built which can extend to the equator. This allows to image diseases involving the whole retina or its periphery by performing a structured fundus examination with a video-slit lamp. Similar images with a video-slit lamp based on a fundus examination through a hand-held non-contact lens have not been demonstrated before. The methods presented enable those ophthalmologists without high-end imaging equipment to monitor pathological fundus findings. The suggested procedure might even be interesting for retinological departments if peripheral findings are to be documented which might be difficult with fundus cameras.
- 15 February 2016
- Published by Springer Nature in International Ophthalmology
- Vol. 36 (6) , 775-780
A simple method for panretinal imaging with the slit lamp
Slit lamp biomicroscopy of the retina with a convex lens is a key procedure in clinical practice. The methods presented enable ophthalmologists to adequately image large and peripheral parts of the fundus using a video-slit lamp and freely available stitching software. A routine examination of the fundus with a slit lamp and a +90 D lens is recorded on a video film. Later, sufficiently sharp still images are identified on the video sequence. These still images are imported into a freely available image-processing program (Hugin, for stitching mosaics together digitally) and corresponding points are marked on adjacent still images with some overlap. Using the digital stitching program Hugin panoramic overviews of the retina can be built which can extend to the equator. This allows to image diseases involving the whole retina or its periphery by performing a structured fundus examination with a video-slit lamp. Similar images with a video-slit lamp based on a fundus examination through a hand-held non-contact lens have not been demonstrated before. The methods presented enable those ophthalmologists without high-end imaging equipment to monitor pathological fundus findings. The suggested procedure might even be interesting for retinological departments if peripheral findings are to be documented which might be difficult with fundus cameras.
- 1 February 2015
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 53 (2) , 208-209
Customised reconstruction of the orbital wall and engineering of selective laser melting (SLM) core implants
- 1 February 2015
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 53 (2) , 208-209
Customised reconstruction of the orbital wall and engineering of selective laser melting (SLM) core implants
- 3 October 2013
- Published by Taylor & Francis in Strabismus
- Vol. 21 (4) , 209-215
The Orthoptic Slit Lamp
Recently we presented our concept of “videography with the slit lamp,” which provides an imaging solution for nearly every pathological finding in ophthalmology. This paper deals with the changes that must be made to prepare the slit lamp for documenting squint. To achieve this goal we propose: 1. Changes in the observation system: minus lenses in front of the objective of the slit lamp to achieve a sharp image of both eyes (eg, −8 diopters [dpt] if the patient sits at a distance of 50 cm). 2. Changes in the illumination system: minimizing the narrowed angle between illumination and observation axis by holding a “recentration” prism of 14 dpt horizontally in front of the slit light. This procedure creates equally sufficient illumination of the patient’s face and central corneal reflexes. 3. Recording clinical findings with a digital recorder. This enables us to identify binocular eye positions, which sometimes last only part of a second, eg, in latent or intermittent strabism. 4. Visualizing clinical findings by using Microsoft PowerPoint® to build up 9-gaze composites or adjust corneal reflexes on subsequent foils. Changes in binocular eye positions (eg, after surgery, but also during diagnostic covering) can be made visible by flickering between the foils to compare.
- 3 October 2013
- Published by Taylor & Francis in Strabismus
- Vol. 21 (4) , 209-215
The Orthoptic Slit Lamp
Recently we presented our concept of “videography with the slit lamp,” which provides an imaging solution for nearly every pathological finding in ophthalmology. This paper deals with the changes that must be made to prepare the slit lamp for documenting squint. To achieve this goal we propose: 1. Changes in the observation system: minus lenses in front of the objective of the slit lamp to achieve a sharp image of both eyes (eg, −8 diopters [dpt] if the patient sits at a distance of 50 cm). 2. Changes in the illumination system: minimizing the narrowed angle between illumination and observation axis by holding a “recentration” prism of 14 dpt horizontally in front of the slit light. This procedure creates equally sufficient illumination of the patient’s face and central corneal reflexes. 3. Recording clinical findings with a digital recorder. This enables us to identify binocular eye positions, which sometimes last only part of a second, eg, in latent or intermittent strabism. 4. Visualizing clinical findings by using Microsoft PowerPoint® to build up 9-gaze composites or adjust corneal reflexes on subsequent foils. Changes in binocular eye positions (eg, after surgery, but also during diagnostic covering) can be made visible by flickering between the foils to compare.
- 13 December 2011
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 228 (12) , 1092-1102
Videografie mit der Spaltlampe
Hintergrund: Viele neue Geräte wurden in den letzten Jahren zur Bildgebung in der Augenheilkunde eingeführt, besonders für Netzhauterkrankungen und zur Glaukomdiagnostik. Die Spaltlampe jedoch, das wichtigste Instrument der praktischen augenärztlichen Tätigkeit, ist seit Jahrzehnten nicht wesentlich verändert worden. Es wird gezeigt, dass man mit einer Video-Spaltlampe ein deutlich breiteres Spektrum ophthalmologischer Erkrankungen dokumentieren kann, als dies gegenwärtig üblich ist. Die erforderlichen Methoden fassen wir unter dem Begriff Videografie zusammen. Methoden: Der apparative Zusatzaufwand ist gering (Funduslupen, Minuslinsen, Rezentrierungsprisma, allgemein verfügbare PC-Programme). Für die Videografie mit der Spaltlampe kommen zum Einsatz: 1. spezielle Überlegungen zur Beleuchtung; 2. die Sequenzanalyse von Videoaufzeichnungen; 3. Bildzusammenstellungen vor allem für topografische Übersichten; 4. der Flickertest, der erlaubt, Veränderungen des Gewebes durch Scheinbewegungen zu erkennen. Ergebnisse: Diese Methoden und Techniken der Videografie eröffnen der Bildgebung mit der Spaltlampe in der Augenheilkunde neue Felder. Dies betrifft insbesondere die Netzhaut (z. B. Verlaufsbeurteilung beim Glaukom und bei Makulaerkrankungen) und das Gesicht (z. B. Fotodokumentation bei Schielen). Dies wird jeweils mit Beispielen belegt. Schlussfolgerung: Augenärzte, vor allem ohne Zugang zu einer professionellen Fotoabteilung, sollen ermutigt werden, dass man allein mit einer Video-Spaltlampe nahezu alle klinischen Befunde effizient im Bild festhalten kann, sofern klare Konzepte angewendet werden, wie sie die Videografie zur Verfügung stellt. Background: Many new diagnostic instruments have been introduced for imaging in ophthalmology, particularly for retinal diseases and diagnostics in glaucoma. The slit lamp, however, as the most important instrument in practical ophthalmological work, has been largely unchanged for decades. It will be shown that a video slit lamp can be used for monitoring of a much broader spectrum of ophthalmological diseases than is commonly used at present. We name the required methods and techniques collectively videography. Methods: There are only few additional technical requirements (fundus lenses, minus lenses, recentration prism, generally available computer programmes). The following methods and techniques are applied in slit lamp videography: 1) special considerations of illumination; 2) sequential analysis of video recordings; 3) picture composites especially for topographic overviews; 4) the flicker test to detect changes in ocular tissue by virtual movement. Results: These methods and techniques of videography open new fields for slit lamp imaging in ophthalmology – equally of the retina (e. g., follow-up in glaucoma and macular disease) and face (e. g., photography of squint). Illustrative examples are given. Conclusions: Ophthalmologists, especially those without access to a professional photographic unit, should be encouraged that with a video slit lamp nearly all clinical findings can be documented efficiently if clear concepts – as given by videography – exist as to what is to be done.
- 13 December 2011
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 228 (12) , 1092-1102
Videografie mit der Spaltlampe
Hintergrund: Viele neue Geräte wurden in den letzten Jahren zur Bildgebung in der Augenheilkunde eingeführt, besonders für Netzhauterkrankungen und zur Glaukomdiagnostik. Die Spaltlampe jedoch, das wichtigste Instrument der praktischen augenärztlichen Tätigkeit, ist seit Jahrzehnten nicht wesentlich verändert worden. Es wird gezeigt, dass man mit einer Video-Spaltlampe ein deutlich breiteres Spektrum ophthalmologischer Erkrankungen dokumentieren kann, als dies gegenwärtig üblich ist. Die erforderlichen Methoden fassen wir unter dem Begriff Videografie zusammen. Methoden: Der apparative Zusatzaufwand ist gering (Funduslupen, Minuslinsen, Rezentrierungsprisma, allgemein verfügbare PC-Programme). Für die Videografie mit der Spaltlampe kommen zum Einsatz: 1. spezielle Überlegungen zur Beleuchtung; 2. die Sequenzanalyse von Videoaufzeichnungen; 3. Bildzusammenstellungen vor allem für topografische Übersichten; 4. der Flickertest, der erlaubt, Veränderungen des Gewebes durch Scheinbewegungen zu erkennen. Ergebnisse: Diese Methoden und Techniken der Videografie eröffnen der Bildgebung mit der Spaltlampe in der Augenheilkunde neue Felder. Dies betrifft insbesondere die Netzhaut (z. B. Verlaufsbeurteilung beim Glaukom und bei Makulaerkrankungen) und das Gesicht (z. B. Fotodokumentation bei Schielen). Dies wird jeweils mit Beispielen belegt. Schlussfolgerung: Augenärzte, vor allem ohne Zugang zu einer professionellen Fotoabteilung, sollen ermutigt werden, dass man allein mit einer Video-Spaltlampe nahezu alle klinischen Befunde effizient im Bild festhalten kann, sofern klare Konzepte angewendet werden, wie sie die Videografie zur Verfügung stellt. Background: Many new diagnostic instruments have been introduced for imaging in ophthalmology, particularly for retinal diseases and diagnostics in glaucoma. The slit lamp, however, as the most important instrument in practical ophthalmological work, has been largely unchanged for decades. It will be shown that a video slit lamp can be used for monitoring of a much broader spectrum of ophthalmological diseases than is commonly used at present. We name the required methods and techniques collectively videography. Methods: There are only few additional technical requirements (fundus lenses, minus lenses, recentration prism, generally available computer programmes). The following methods and techniques are applied in slit lamp videography: 1) special considerations of illumination; 2) sequential analysis of video recordings; 3) picture composites especially for topographic overviews; 4) the flicker test to detect changes in ocular tissue by virtual movement. Results: These methods and techniques of videography open new fields for slit lamp imaging in ophthalmology – equally of the retina (e. g., follow-up in glaucoma and macular disease) and face (e. g., photography of squint). Illustrative examples are given. Conclusions: Ophthalmologists, especially those without access to a professional photographic unit, should be encouraged that with a video slit lamp nearly all clinical findings can be documented efficiently if clear concepts – as given by videography – exist as to what is to be done.