Kunihiro Matsui
Research Subjects
Research Interests
Kunihiro Matsui has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Norikiyo Koizumi
QST Naka, Ibaraki, Japan
8 shared publications - Takaaki Isono
National Institutes for Quantum and Radiological Science and Technology, Naka Japan
7 shared publications - Yoshikazu Takahashi
Japan Atomic Energy Research Institute
6 shared publications Toshinari Ando
4 shared publicationsYoshihiko Nunoya
Japan Atomic Energy Agency, Naka, Japan
4 shared publicationsKiyoshi Okuno
Japan Atomic Energy Agency, Naka, Japan
3 shared publications
Latest Publications
- 21 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (4) , 1-5
Performance Analysis of Mass-Produced Nb3Sn Conductor for Central Solenoid in ITER
The performance of two mass-produced Nb 3 Sn conductors for the ITER central solenoids was tested for the first timmass-produced Nb 3 Sn conductorse. One was cut from the forward end of an 80-m-long conductor, and the other was cut from the forward end of a 918-m-long conductor. The fifth-stage twist pitches of these conductors were lengthened by approximately 16% during cable insertion and compaction with conduit. The current sharing temperatures Tcs were measured over 20 000 electromagnetic cycles, including four thermal cycles between 4.2 K and room temperature. The T cs of the former conductor increased and became almost constant through the cycling. In contrast, T cs of the latter conductor not only increased but also decreased slightly against cycling. The T cs decline rate after 10002 cycles was -4.50 × 10-6 K/cycle. If this rate is assumed to continue after 20000 cycles, Tcs would decrease by -0.27 K over 60000 cycles. Even so, T cs is higher than an acceptance criterion of 6.5 K at 60 000 cycles. The ac losses Q of both conductors at a current of 0 kA were almost the same as or slightly lower than Q of a short sample conductor whose fifth-stage twist pitch was not lengthen. On each conductor, Q at 40 kA was approximately 10% higher than that at 0 kA; thus, the effect of the transport current on Q was not large.
- 21 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (4) , 1-5
Performance Analysis of Mass-Produced Nb3Sn Conductor for Central Solenoid in ITER
The performance of two mass-produced Nb 3 Sn conductors for the ITER central solenoids was tested for the first timmass-produced Nb 3 Sn conductorse. One was cut from the forward end of an 80-m-long conductor, and the other was cut from the forward end of a 918-m-long conductor. The fifth-stage twist pitches of these conductors were lengthened by approximately 16% during cable insertion and compaction with conduit. The current sharing temperatures Tcs were measured over 20 000 electromagnetic cycles, including four thermal cycles between 4.2 K and room temperature. The T cs of the former conductor increased and became almost constant through the cycling. In contrast, T cs of the latter conductor not only increased but also decreased slightly against cycling. The T cs decline rate after 10002 cycles was -4.50 × 10-6 K/cycle. If this rate is assumed to continue after 20000 cycles, Tcs would decrease by -0.27 K over 60000 cycles. Even so, T cs is higher than an acceptance criterion of 6.5 K at 60 000 cycles. The ac losses Q of both conductors at a current of 0 kA were almost the same as or slightly lower than Q of a short sample conductor whose fifth-stage twist pitch was not lengthen. On each conductor, Q at 40 kA was approximately 10% higher than that at 0 kA; thus, the effect of the transport current on Q was not large.
- 24 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Evaluation of ITER TF Coil Joint Performance
To evaluate the ITER TF joint performance, the joint test sample, which consists of two short TF conductors and has full size joint, shall be tested using NIFS test facility under the condition of current of 68 kA and external field of 2 T. For high accuracy, the issue of voltage difference between cable and jacket had been anticipated in the evaluation of joint resistance. If a voltage difference exist between them, it is difficult to measure real joint resistance using voltage taps on the jacket. Therefore, the author first calculated the position where voltage of cable and jacket become equipotential and then decided the voltage tap position where the influence of voltage drop could be avoided. Thus, a high accuracy measurement of joint resistance could be achieved and the joint resistance was accurately evaluated as around 1 nΩ, which is well below the ITER requirement of 3 nΩ.
- 24 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Evaluation of ITER TF Coil Joint Performance
To evaluate the ITER TF joint performance, the joint test sample, which consists of two short TF conductors and has full size joint, shall be tested using NIFS test facility under the condition of current of 68 kA and external field of 2 T. For high accuracy, the issue of voltage difference between cable and jacket had been anticipated in the evaluation of joint resistance. If a voltage difference exist between them, it is difficult to measure real joint resistance using voltage taps on the jacket. Therefore, the author first calculated the position where voltage of cable and jacket become equipotential and then decided the voltage tap position where the influence of voltage drop could be avoided. Thus, a high accuracy measurement of joint resistance could be achieved and the joint resistance was accurately evaluated as around 1 nΩ, which is well below the ITER requirement of 3 nΩ.
- 13 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Non-Destructive Examination of Jacket Sections for ITER Central Solenoid Conductors
The Japan Atomic Energy Agency is responsible for procuring all amounts of central solenoid (CS) conductors for International Thermonuclear Experimental Reactor, including CS jacket sections. The conductor is cable-in-conduit conductor with a central spiral. A total of 576 Nb 3 Sn strands and 288 copper strands are cabled around the central spiral and then wrapped with stainless steel tape whose thickness is 0.08 mm. The maximum operating current is 40 kA at magnetic field of 13 T. CS jacket section is circular in square type tube made of JK2LB, which is high manganese stainless steel with boron added. Unit length of jacket sections is 7 m, and 6400 sections will be manufactured and inspected. Outer/inner dimension and weight are 51.3/35.3 mm and around 100 kg, respectively. Since the CS conductor suffers 60000 cycles of high electromagnetic force in the lifetime, severe requirements were specified for jacket sections in terms of not only high mechanical performance at 4 K but also of the size of initial defects in the jacket section. The minimum allowable defect size is estimated to be 2 mm2 × 0.2 mm by linear elastic fracture mechanics. Eddy current test (ECT) and phased array ultrasonic test (PAUT) were developed for non-destructive examination. The defects on inner and outer surfaces can be detected by ECT. The defects inside the jacket section can be detected by PAUT. These technologies and the inspected results of more than 700 jacket sections are reported in this paper.
- 13 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Non-Destructive Examination of Jacket Sections for ITER Central Solenoid Conductors
The Japan Atomic Energy Agency is responsible for procuring all amounts of central solenoid (CS) conductors for International Thermonuclear Experimental Reactor, including CS jacket sections. The conductor is cable-in-conduit conductor with a central spiral. A total of 576 Nb 3 Sn strands and 288 copper strands are cabled around the central spiral and then wrapped with stainless steel tape whose thickness is 0.08 mm. The maximum operating current is 40 kA at magnetic field of 13 T. CS jacket section is circular in square type tube made of JK2LB, which is high manganese stainless steel with boron added. Unit length of jacket sections is 7 m, and 6400 sections will be manufactured and inspected. Outer/inner dimension and weight are 51.3/35.3 mm and around 100 kg, respectively. Since the CS conductor suffers 60000 cycles of high electromagnetic force in the lifetime, severe requirements were specified for jacket sections in terms of not only high mechanical performance at 4 K but also of the size of initial defects in the jacket section. The minimum allowable defect size is estimated to be 2 mm2 × 0.2 mm by linear elastic fracture mechanics. Eddy current test (ECT) and phased array ultrasonic test (PAUT) were developed for non-destructive examination. The defects on inner and outer surfaces can be detected by ECT. The defects inside the jacket section can be detected by PAUT. These technologies and the inspected results of more than 700 jacket sections are reported in this paper.
- 1 January 2001
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 36 (8) , 478-485
Evaluation of Critical Current Performance of an Nb3Al Conductor with Stainless Steel Conduit.
An Nb3Al conductor with stainless steel (SS) conduit has been developed in the framework of ITER Engineering Design Activity. The critical current performance of this conductor was experimentally investigated by using a short conductor sample. The results show that the critical current achieves the expected, resulting in demonstrating the validity of the fabrication method. The thermal strain is generally applied to the strands if SS conduit is used because of the different thermal expansion between the strands and SS conduit. However, it was not applied in our sample, since the conductor length, a few meters, is too short to keep it by friction force between the cable and conduit. The thermal strain applied to the strands in a long conductor is therefore estimated by using the solid model, in which the strain on the strands and conduit are calculated from the equilibrium of their thermal forces, ignoring the effect of cabling on relaxation of the strain on the strands. The results indicate that the Nb3Al strands are subjected to a compressive thermal strain of less than 0.4%. The critical current degradation by this is less than 10%, even though the SS conduit is used. Consequently, its critical current is estimated to be 90kA, which is sufficiently high compared with the nominal, 46kA, at 13T and 4.5K. Furthermore, it should be noted that the large thermal force, 80kN, appears after the heat treatment at room temperature.
- 1 January 2001
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 36 (8) , 478-485
Evaluation of Critical Current Performance of an Nb3Al Conductor with Stainless Steel Conduit.
An Nb3Al conductor with stainless steel (SS) conduit has been developed in the framework of ITER Engineering Design Activity. The critical current performance of this conductor was experimentally investigated by using a short conductor sample. The results show that the critical current achieves the expected, resulting in demonstrating the validity of the fabrication method. The thermal strain is generally applied to the strands if SS conduit is used because of the different thermal expansion between the strands and SS conduit. However, it was not applied in our sample, since the conductor length, a few meters, is too short to keep it by friction force between the cable and conduit. The thermal strain applied to the strands in a long conductor is therefore estimated by using the solid model, in which the strain on the strands and conduit are calculated from the equilibrium of their thermal forces, ignoring the effect of cabling on relaxation of the strain on the strands. The results indicate that the Nb3Al strands are subjected to a compressive thermal strain of less than 0.4%. The critical current degradation by this is less than 10%, even though the SS conduit is used. Consequently, its critical current is estimated to be 90kA, which is sufficiently high compared with the nominal, 46kA, at 13T and 4.5K. Furthermore, it should be noted that the large thermal force, 80kN, appears after the heat treatment at room temperature.
- 1 January 1998
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 33 (7) , 473-478
The SMES Model Coil. Test Results of the SMES Model Coil. DC Electromagnetic Performance.
An experiment of a SMES model coil was successfully carried out at the ITER test facility of the Japan Atomic Energy Research Institute (JAERI) in 1996, in collaboration with the International Superconductivity Technology Center (ISTEC). The coil was charged up to its rated current of 20kA at 2.8T without quenching, and then charged up to 35.4kA for extended testing. The electromagnetic performance of the coil was tested by measuring critical current (Ic) and current sharing temperature (Tcs), and no degradation was observed.
- 1 January 1998
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 33 (7) , 473-478
The SMES Model Coil. Test Results of the SMES Model Coil. DC Electromagnetic Performance.
An experiment of a SMES model coil was successfully carried out at the ITER test facility of the Japan Atomic Energy Research Institute (JAERI) in 1996, in collaboration with the International Superconductivity Technology Center (ISTEC). The coil was charged up to its rated current of 20kA at 2.8T without quenching, and then charged up to 35.4kA for extended testing. The electromagnetic performance of the coil was tested by measuring critical current (Ic) and current sharing temperature (Tcs), and no degradation was observed.
- 1 January 1998
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 33 (9) , 629-637
Current Status of the R&D on Jelly-roll Processed Nb3Al Conductors.
Nb3Al superconductors have a strain tolerance superior to Nb3Sn superconductors. Nb3Al superconductors have been expected to be useful for high-field applications, such as high-energy physics (particle accelerators) and fusion reactors. In this paper, Nb3Al wire processing technologies are summarized, and the properties of Nb3Al strands made by the jelly-roll process are described. The jelly-roll process was suitable to develop copper-stabilized multifilamentary composites. For the high-energy physics application, a Rutherford-type cable conductor was developed. For the fusion reactor application, a chrome-plated strand with a critical current density performance of at least 600A/mm2 at 4.2K and 12T was developed, and 230km strands, the world's first mass-produced Nb3Al wire, were fabricated for the Insert Coil of ITER/EDA.
- 1 January 1998
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 33 (9) , 629-637
Current Status of the R&D on Jelly-roll Processed Nb3Al Conductors.
Nb3Al superconductors have a strain tolerance superior to Nb3Sn superconductors. Nb3Al superconductors have been expected to be useful for high-field applications, such as high-energy physics (particle accelerators) and fusion reactors. In this paper, Nb3Al wire processing technologies are summarized, and the properties of Nb3Al strands made by the jelly-roll process are described. The jelly-roll process was suitable to develop copper-stabilized multifilamentary composites. For the high-energy physics application, a Rutherford-type cable conductor was developed. For the fusion reactor application, a chrome-plated strand with a critical current density performance of at least 600A/mm2 at 4.2K and 12T was developed, and 230km strands, the world's first mass-produced Nb3Al wire, were fabricated for the Insert Coil of ITER/EDA.
- 1 January 1997
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 32 (6) , 263-270
Calibration of Inductive Heating Energy Deposited on a Cable-in-Conduit Conductor Using a Calorimetric Method.
The inductive heating method is often used to originate initial normalcy in a stability experiment of a cable-in-conduit conductor (CICC). However, its magnitude cannot be evaluated easily. The calibration method to determine the CICC's inductive heating energy using a calorimetric technique was studied, and the inductive heating energies of two CICCs whose geometries were different from one another were successively evaluated applying this method. In addition, the experimental results show that the eddy currents in the strands and conduit electrically couple separately from one another and that this phenomenon affects the heating energy in the strands and conduit. The inductive heating energy in the strands and conduit was evaluated taking into account this effect.
- 1 January 1997
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 32 (6) , 263-270
Calibration of Inductive Heating Energy Deposited on a Cable-in-Conduit Conductor Using a Calorimetric Method.
The inductive heating method is often used to originate initial normalcy in a stability experiment of a cable-in-conduit conductor (CICC). However, its magnitude cannot be evaluated easily. The calibration method to determine the CICC's inductive heating energy using a calorimetric technique was studied, and the inductive heating energies of two CICCs whose geometries were different from one another were successively evaluated applying this method. In addition, the experimental results show that the eddy currents in the strands and conduit electrically couple separately from one another and that this phenomenon affects the heating energy in the strands and conduit. The inductive heating energy in the strands and conduit was evaluated taking into account this effect.