Mikio Takeda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mikio Takeda has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Mitsuo Manaka
Geological Survey of Japan, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8567, Japan
4 shared publications T. Hiratsuka
National Institute of Advanced Industrial Science and Technology (AIST) Tsukuba Japan
4 shared publicationsAkinobu Miyakoshi
2 shared publications- Daisuke Asahina
Geological Survey of Japan, AIST, Tsukuba, Japan
2 shared publications H. Nakajima
Japan Science and Technology Agency (JST), Sanbancho Bldg. 5, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
2 shared publicationsHinako Hosono
2 shared publications
Latest Publications
- Open Access
Dissolved Oxygen Diffusion and Consumption in Tuffaceous Sandstone: A Luminescence-Based Oxygen Measurement Approach for Intact Rocks
Dissolved oxygen (DO) remaining in radioactive waste repositories after backfilling is expected to be consumed by Fe(II)-bearing geological media, limiting redox-sensitive radionuclide migration into groundwater. However, DO consumption rates have been primarily evaluated using crushed samples, with limited research on intact rock samples comprising Fe(II)-bearing primary and clay minerals. To address this limitation, this study developed a simple experimental apparatus using a non-consumptive luminescence-based oxygen sensor that enables high-precision DO measurements with minimal artifacts. For validation, DO diffusion and consumption experiments were conducted using Kimachi tuffaceous sandstone (Japan) (porosity, 21.2%; smectite content, 29 wt.%) to evaluate the swelling effect of smectite. In this laboratory-scale study, the newly obtained rate constant was (6.55 ± 7.52) × 10−3 L mol−1 s−1, which was comparable to previously reported values of (1.57 ± 4.05) × 10−3 L mol−1 s−1. This result provides empirical support for the previously proposed mechanism that smectite swelling, which could potentially alter DO consumption, is constrained by the rigid rock structure, thereby maintaining a consumption rate similar to that of other Fe(II)-bearing geological media. Furthermore, by integrating previous findings indicating that effective DO diffusion coefficients (3.2 × 10−12 to 2.3 × 10−9 m2 s−1) depend on geological media porosity (21.2%–81.5%), these empirical laboratory parameters can be used to model and predict the transition from oxic to anoxic conditions in full-scale geological repository systems.
Open AccessDissolved Oxygen Diffusion and Consumption in Tuffaceous Sandstone: A Luminescence-Based Oxygen Measurement Approach for Intact Rocks
Dissolved oxygen (DO) remaining in radioactive waste repositories after backfilling is expected to be consumed by Fe(II)-bearing geological media, limiting redox-sensitive radionuclide migration into groundwater. However, DO consumption rates have been primarily evaluated using crushed samples, with limited research on intact rock samples comprising Fe(II)-bearing primary and clay minerals. To address this limitation, this study developed a simple experimental apparatus using a non-consumptive luminescence-based oxygen sensor that enables high-precision DO measurements with minimal artifacts. For validation, DO diffusion and consumption experiments were conducted using Kimachi tuffaceous sandstone (Japan) (porosity, 21.2%; smectite content, 29 wt.%) to evaluate the swelling effect of smectite. In this laboratory-scale study, the newly obtained rate constant was (6.55 ± 7.52) × 10−3 L mol−1 s−1, which was comparable to previously reported values of (1.57 ± 4.05) × 10−3 L mol−1 s−1. This result provides empirical support for the previously proposed mechanism that smectite swelling, which could potentially alter DO consumption, is constrained by the rigid rock structure, thereby maintaining a consumption rate similar to that of other Fe(II)-bearing geological media. Furthermore, by integrating previous findings indicating that effective DO diffusion coefficients (3.2 × 10−12 to 2.3 × 10−9 m2 s−1) depend on geological media porosity (21.2%–81.5%), these empirical laboratory parameters can be used to model and predict the transition from oxic to anoxic conditions in full-scale geological repository systems.
- Open Access
- 18 March 2025
- Published by Copernicus GmbH
Characterizing Fault Zone Hydrology Using a Coupled Geophysical and Modeling Approach
Fault zones can play a critical role in controlling small to large scale groundwater flow. Extensive studies have focused on permeability variations along faults in terms of conduit or barrier function for deep groundwater flow. However, little attempt has been made to characterize the hydrologic functions of near-surface fault zones.When exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, acting as a near-surface recharge or discharge zone, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of such a fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study presents a multiphysics coupled strategy to characterize the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The multiphysics approach consists of 5 consecutive steps:Electrical Resistivity Tomography (ERT) Survey: A 3.8 km-long profile across the fault zone, with 20 m electrode spacing. Self-Potential (SP) survey: Conducted along the ERT profile. Rock property characterization: A 160 m deep borehole was drilled in the fault zone and physical properties were measured. Groundwater flow simulation of the fault zone: Using hydrogeological data, measured rock properties and a 3D geological model. Model evaluation: Post-processing of the groundwater flow simulation to calculate synthetic electrical resistivity and self-potential responses and comparison with observed field data. The fault zone is identified by a sharp structural change between conductive and resistive geologic units, which also exhibit a small but shifted SP jump (+20 mV) signal. Our model evaluation process reproduces the entire ERT and SP data.This newly proposed multiphysics approach offers a robust tool for monitoring groundwater flow in geologically complex regions, with applications in radioactive waste disposal safety, groundwater contamination management, and understanding hydrogeologic processes in tectonically active areas.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- 18 March 2025
- Published by Copernicus GmbH
Open AccessCharacterizing Fault Zone Hydrology Using a Coupled Geophysical and Modeling Approach
Fault zones can play a critical role in controlling small to large scale groundwater flow. Extensive studies have focused on permeability variations along faults in terms of conduit or barrier function for deep groundwater flow. However, little attempt has been made to characterize the hydrologic functions of near-surface fault zones.When exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, acting as a near-surface recharge or discharge zone, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of such a fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study presents a multiphysics coupled strategy to characterize the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The multiphysics approach consists of 5 consecutive steps:Electrical Resistivity Tomography (ERT) Survey: A 3.8 km-long profile across the fault zone, with 20 m electrode spacing. Self-Potential (SP) survey: Conducted along the ERT profile. Rock property characterization: A 160 m deep borehole was drilled in the fault zone and physical properties were measured. Groundwater flow simulation of the fault zone: Using hydrogeological data, measured rock properties and a 3D geological model. Model evaluation: Post-processing of the groundwater flow simulation to calculate synthetic electrical resistivity and self-potential responses and comparison with observed field data. The fault zone is identified by a sharp structural change between conductive and resistive geologic units, which also exhibit a small but shifted SP jump (+20 mV) signal. Our model evaluation process reproduces the entire ERT and SP data.This newly proposed multiphysics approach offers a robust tool for monitoring groundwater flow in geologically complex regions, with applications in radioactive waste disposal safety, groundwater contamination management, and understanding hydrogeologic processes in tectonically active areas.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Coupled multiphysics approach to characterize groundwater flow system around a near-surface fault zone
Fault zones intensively disturb local hydrogeologic structures, and, consequently, can play a critical role in governing small to large-scale groundwater flow. Extensive studies have focused on the permeability variation along faults in the light of the conduit or barrier function for the deep groundwater flow. However, little attempt has been made to characterize the hydrological functions of near-surface fault zone.Exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, which functions as a recharge or discharge zone at the near surface, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of near-surface fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study proposes a multiphysics coupled strategy to understand the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The proposed multiphysics approach consists of 5 successive steps:2-D Electrical Resistivity Tomography (ERT) Survey: A 2.3 km-long profile crossing the fault zone, consisting of 7 roll-along surveys with a 6-m electrode spacing. Self-Potential Survey: Conducted along the 2.3 km ERT profile. Rock Property Characterization: A 80 m deep borehole was drilled in the fault zone and physical properties were measured. 3-D Groundwater Flow Simulation of the Fault Zone: Utilizing areal hydrogeological data, measured rock properties, and geophysical imaging. Model Validation Process: Using the results from the groundwater flow simulation, electrical conductivity and self-potential responses were calculated, and compared with observed field data. Preliminary results successfully reproduce the overall resistivity signature and the self-potential anomaly (+35 mV) in the fault zone, attributed to local groundwater upwelling. This newly proposed multiphysics approach could be an essential tool to evaluate the groundwater flow in a region including large-size fault zone, which is important for radioactive waste disposal. Furthermore, this approach could also be effective in capturing the local fluid flow circulation for a variety of applications.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessCoupled multiphysics approach to characterize groundwater flow system around a near-surface fault zone
Fault zones intensively disturb local hydrogeologic structures, and, consequently, can play a critical role in governing small to large-scale groundwater flow. Extensive studies have focused on the permeability variation along faults in the light of the conduit or barrier function for the deep groundwater flow. However, little attempt has been made to characterize the hydrological functions of near-surface fault zone.Exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, which functions as a recharge or discharge zone at the near surface, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of near-surface fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study proposes a multiphysics coupled strategy to understand the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The proposed multiphysics approach consists of 5 successive steps:2-D Electrical Resistivity Tomography (ERT) Survey: A 2.3 km-long profile crossing the fault zone, consisting of 7 roll-along surveys with a 6-m electrode spacing. Self-Potential Survey: Conducted along the 2.3 km ERT profile. Rock Property Characterization: A 80 m deep borehole was drilled in the fault zone and physical properties were measured. 3-D Groundwater Flow Simulation of the Fault Zone: Utilizing areal hydrogeological data, measured rock properties, and geophysical imaging. Model Validation Process: Using the results from the groundwater flow simulation, electrical conductivity and self-potential responses were calculated, and compared with observed field data. Preliminary results successfully reproduce the overall resistivity signature and the self-potential anomaly (+35 mV) in the fault zone, attributed to local groundwater upwelling. This newly proposed multiphysics approach could be an essential tool to evaluate the groundwater flow in a region including large-size fault zone, which is important for radioactive waste disposal. Furthermore, this approach could also be effective in capturing the local fluid flow circulation for a variety of applications.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- 1 September 2018
- Published by Elsevier in Journal of Hydrology
- Vol. 564, 1058-1073
An experimental examination of the effect of the salt type on the chemo-osmotic, diffusive, and hydraulic parameters of Wakkanai mudstones
- 1 September 2018
- Published by Elsevier in Journal of Hydrology
- Vol. 564, 1058-1073
An experimental examination of the effect of the salt type on the chemo-osmotic, diffusive, and hydraulic parameters of Wakkanai mudstones
- Open Access
- 12 June 2018
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 45 (11) , 5427-5435
Effects of Confining Stress on the Semipermeability of Siliceous Mudstones: Implications for Identifying Geologic Membrane Behaviors of Argillaceous Formations
The semipermeability arising from filtration effects on ionic species at the pore spaces in clay minerals has been recognized as a fundamental transport property of argillites. However, little is known about the dependence of the semipermeability on the confining stress that controls the pore sizes. Thus, we investigated the evolution of the semipermeability during cyclic loading by performing chemical osmosis experiments on siliceous mudstones. Results show that the semipermeability irreversibly increases with increasing confining stress, but once the stress exceeds the past maximum effective burial stress, it reversibly changes in accordance with the change in the stress. The net increase in the semipermeability from the first loading cycle to the last unloading cycle implies the irreversible shrinking of pores that should have expanded owing to stress relief before testing. The reversible change in the semipermeability probably reflects the reversible pore deformation due to the elasticity of argillites in the overconsolidated state.
- 12 June 2018
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 45 (11) , 5427-5435
Open AccessEffects of Confining Stress on the Semipermeability of Siliceous Mudstones: Implications for Identifying Geologic Membrane Behaviors of Argillaceous Formations
The semipermeability arising from filtration effects on ionic species at the pore spaces in clay minerals has been recognized as a fundamental transport property of argillites. However, little is known about the dependence of the semipermeability on the confining stress that controls the pore sizes. Thus, we investigated the evolution of the semipermeability during cyclic loading by performing chemical osmosis experiments on siliceous mudstones. Results show that the semipermeability irreversibly increases with increasing confining stress, but once the stress exceeds the past maximum effective burial stress, it reversibly changes in accordance with the change in the stress. The net increase in the semipermeability from the first loading cycle to the last unloading cycle implies the irreversible shrinking of pores that should have expanded owing to stress relief before testing. The reversible change in the semipermeability probably reflects the reversible pore deformation due to the elasticity of argillites in the overconsolidated state.
- Open Access
- 29 April 2014
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Solid Earth
- Vol. 119 (5) , 4178-4201
Experimental examination of the relationships among chemico‐osmotic, hydraulic, and diffusion parameters of Wakkanai mudstones
Sequential permeability and chemical osmosis experiments on Wakkanai mudstones were performed to explore the relationships between the semipermeability of clayey rocks and the hydraulic and diffusion parameters as well as the pore structure characteristics. The wide ranges in osmotic efficiency (0.0004–0.046) and intrinsic permeability (8.92 × 10−20 to 1.24 × 10−17 m2) reflect the variation in the pore size distributions of the Wakkanai mudstones. A regression analysis between osmotic efficiency and permeability shows that the osmotic efficiency is proportional to the inverse of permeability, suggesting that the permeability is indeed indicative of the degree of semipermeability. Osmotic efficiency was determined invariant with the effective diffusion coefficient for the Wakkanai mudstones (3.59–8.36 × 10−11 m2/s) due to their small osmotic efficiencies (≤0.046). The wide variation in osmotic efficiencies and pore structure characteristics of Wakkanai mudstones indicates that the nanoscale pores enable semipermeability in Wakkanai mudstones. However, the pressure evolution caused by chemical osmosis is limited by the connected wide pores that are the main conduits for water, thus dissipating the osmotic pressure buildup induced by the semipermeability of nanoscale pores.
- 29 April 2014
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Solid Earth
- Vol. 119 (5) , 4178-4201
Open AccessExperimental examination of the relationships among chemico‐osmotic, hydraulic, and diffusion parameters of Wakkanai mudstones
Sequential permeability and chemical osmosis experiments on Wakkanai mudstones were performed to explore the relationships between the semipermeability of clayey rocks and the hydraulic and diffusion parameters as well as the pore structure characteristics. The wide ranges in osmotic efficiency (0.0004–0.046) and intrinsic permeability (8.92 × 10−20 to 1.24 × 10−17 m2) reflect the variation in the pore size distributions of the Wakkanai mudstones. A regression analysis between osmotic efficiency and permeability shows that the osmotic efficiency is proportional to the inverse of permeability, suggesting that the permeability is indeed indicative of the degree of semipermeability. Osmotic efficiency was determined invariant with the effective diffusion coefficient for the Wakkanai mudstones (3.59–8.36 × 10−11 m2/s) due to their small osmotic efficiencies (≤0.046). The wide variation in osmotic efficiencies and pore structure characteristics of Wakkanai mudstones indicates that the nanoscale pores enable semipermeability in Wakkanai mudstones. However, the pressure evolution caused by chemical osmosis is limited by the connected wide pores that are the main conduits for water, thus dissipating the osmotic pressure buildup induced by the semipermeability of nanoscale pores.
- 1 April 2011
- Published by Elsevier in Journal of Contaminant Hydrology
- Vol. 123 (3-4) , 114-129
An axisymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples
- 1 April 2011
- Published by Elsevier in Journal of Contaminant Hydrology
- Vol. 123 (3-4) , 114-129
An axisymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples
- 1 November 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydrologic Engineering
- Vol. 14 (11) , 1200-1207
Applicability of Analytical Models to Single-Well Permeability Tests in Deep and Hydraulically Tight Geological Formations
In situ permeability tests are crucial in hydraulic characterizations of geological formations for the disposal of radioactive nuclear waste. As has been done in most countries where geological disposal of high-level radioactive wastes has been discussed, single-well permeability tests are generally conducted in a preliminary stage of selecting a site where groundwater exists. To determine accurately hydraulic parameters, specifically hydraulic conductivity and specific storage, from single-well permeability tests, it is worth reexamining analytical solutions for modeling test data derived from deep and hydraulically tight (hydraulic conductivity is typically less than ) formations. In hydraulically tight formations, the radius of influence due to a single-well permeability test is not expected to be large, which should be taken into consideration when using the test results. The present paper revisits three major single-well permeability tests, i.e., the pressure pulse, constant head, and constant flow rate tests, and examines the features of natural formations incorporated into the analytical models, such as hydrogeological boundaries, property alterations around a borehole and anisotropy. The radius of influence in a hydraulically tight formation is examined for the three major single-well permeability tests by a numerical approach.- 1 November 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydrologic Engineering
- Vol. 14 (11) , 1200-1207
Applicability of Analytical Models to Single-Well Permeability Tests in Deep and Hydraulically Tight Geological Formations
In situ permeability tests are crucial in hydraulic characterizations of geological formations for the disposal of radioactive nuclear waste. As has been done in most countries where geological disposal of high-level radioactive wastes has been discussed, single-well permeability tests are generally conducted in a preliminary stage of selecting a site where groundwater exists. To determine accurately hydraulic parameters, specifically hydraulic conductivity and specific storage, from single-well permeability tests, it is worth reexamining analytical solutions for modeling test data derived from deep and hydraulically tight (hydraulic conductivity is typically less than ) formations. In hydraulically tight formations, the radius of influence due to a single-well permeability test is not expected to be large, which should be taken into consideration when using the test results. The present paper revisits three major single-well permeability tests, i.e., the pressure pulse, constant head, and constant flow rate tests, and examines the features of natural formations incorporated into the analytical models, such as hydrogeological boundaries, property alterations around a borehole and anisotropy. The radius of influence in a hydraulically tight formation is examined for the three major single-well permeability tests by a numerical approach.