Boris Krasovitski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Boris Krasovitski has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Eitan Kimmel
5 shared publicationsDan Adam
1 shared publicationE. Kimmel
Dept. of Biomed. Eng., Technion-Israel Inst. of Technol., Haifa, Israel
1 shared publicationHanoch Kislev
1 shared publicationIlan Amir
1 shared publicationMichael Rozenfeld
1 shared publication
Latest Publications
- 1 December 2007
- Published by Elsevier in Ultrasonics
- Vol. 47 (1-4) , 90-101
Modeling photothermal and acoustical induced microbubble generation and growth
- 1 December 2007
- Published by Elsevier in Ultrasonics
- Vol. 47 (1-4) , 90-101
Modeling photothermal and acoustical induced microbubble generation and growth
- 1 February 2006
- Published by Elsevier in Ultrasonics
- Vol. 44 (2) , 216-220
Stability of an encapsulated bubble shell
- 1 February 2006
- Published by Elsevier in Ultrasonics
- Vol. 44 (2) , 216-220
Stability of an encapsulated bubble shell
- 24 August 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 51 (8) , 973-979
Shear stress induced by a gas bubble pulsating in an ultrasonic field near a wall
Some of the effects that therapeutic ultrasound has in medicine and biology may be associated with steady oscillations of gas bubbles in liquid, very close to tissue surface. The bubble oscillations induce on the surface steady shear stress attributed to microstreaming. A mathematical simulation of the problem for both free and capsulated bubbles, known as contrast agents, is presented here. The simulation is based on a solution of Laplace's equation for potential flow and existing models for microstreaming. The solution for potential flow was obtained numerically using a boundary integral method. The solution provides the evolution of the bubble shape, the distribution of the velocity potential on the surface, and the shear stress along the surface. The simulation shows that significant shear stresses develop on the surface when the bubble bounces near the tissue surface. In this case, pressure amplitude of 20 kPa generates maximal steady shear stress of several kilo Pascal. Substantial shear stress on the tissue surface takes place inside a circular zone with a radius about half of the bubble radius. The predicted shear stress is greater than stress that causes hemolysis in blood and several orders of magnitude greater than the physiological stress induced on the vessel wall by the flowing blood.
- 24 August 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 51 (8) , 973-979
Shear stress induced by a gas bubble pulsating in an ultrasonic field near a wall
Some of the effects that therapeutic ultrasound has in medicine and biology may be associated with steady oscillations of gas bubbles in liquid, very close to tissue surface. The bubble oscillations induce on the surface steady shear stress attributed to microstreaming. A mathematical simulation of the problem for both free and capsulated bubbles, known as contrast agents, is presented here. The simulation is based on a solution of Laplace's equation for potential flow and existing models for microstreaming. The solution for potential flow was obtained numerically using a boundary integral method. The solution provides the evolution of the bubble shape, the distribution of the velocity potential on the surface, and the shear stress along the surface. The simulation shows that significant shear stresses develop on the surface when the bubble bounces near the tissue surface. In this case, pressure amplitude of 20 kPa generates maximal steady shear stress of several kilo Pascal. Substantial shear stress on the tissue surface takes place inside a circular zone with a radius about half of the bubble radius. The predicted shear stress is greater than stress that causes hemolysis in blood and several orders of magnitude greater than the physiological stress induced on the vessel wall by the flowing blood.
- 1 June 2004
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 30 (6) , 793-802
Ultrasound attenuation by encapsulated microbubbles: time and pressure effects
- 1 June 2004
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 30 (6) , 793-802
Ultrasound attenuation by encapsulated microbubbles: time and pressure effects
- 1 March 2002
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 111 (3) , 1454-1459
A blood vessel exposed to ultrasound: A mathematical simulation of the temperature field
In this article we present a mathematical simulation of the temperature field in and around a blood vessel when it is sonicated by a focused ultrasound beam. A simplified geometry is considered: a cylindrical blood vessel is embedded in tissue parallel to a flat skin surface. The ultrasound transducer is placed on the skin above the blood vessel, perpendicular to the skin surface. The 3D geometry of the problem is simplified by transformation, which maps the domain into a parallelepiped. A computational algorithm and computer program were developed. The simulation provides the conditions for successful occlusion of a blood vessel and demonstrates the significant role of the blood flow rate on the temperature difference between the vessel wall and the surrounding tissue. Comparing the predictions with published experimental data tested the validity of the method.
- 1 March 2002
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 111 (3) , 1454-1459
A blood vessel exposed to ultrasound: A mathematical simulation of the temperature field
In this article we present a mathematical simulation of the temperature field in and around a blood vessel when it is sonicated by a focused ultrasound beam. A simplified geometry is considered: a cylindrical blood vessel is embedded in tissue parallel to a flat skin surface. The ultrasound transducer is placed on the skin above the blood vessel, perpendicular to the skin surface. The 3D geometry of the problem is simplified by transformation, which maps the domain into a parallelepiped. A computational algorithm and computer program were developed. The simulation provides the conditions for successful occlusion of a blood vessel and demonstrates the significant role of the blood flow rate on the temperature difference between the vessel wall and the surrounding tissue. Comparing the predictions with published experimental data tested the validity of the method.
- 28 February 1999
- Published by Elsevier in Journal of Agricultural Engineering Research
- Vol. 72 (2) , 177-185
Aqueous Foams for Frost Protection of Plants: Stability and Protective Properties
- 28 February 1999
- Published by Elsevier in Journal of Agricultural Engineering Research
- Vol. 72 (2) , 177-185
Aqueous Foams for Frost Protection of Plants: Stability and Protective Properties