SASuzanne L. Aquino

Suzanne L. Aquino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suzanne L. Aquino has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimal CT Breathing Protocol for Combined Thoracic PET/CT

    by Matthew D. Gilman, Alan J. Fischman, Vikram Krishnasetty, Elkan F. Halpern, Suzanne L. Aquino

    OBJECTIVE. The objective of this study was to determine the optimal breathing protocol for combined PET/CT scans of the thorax.SUBJECTS AND METHODS. Eighty combined PET/CT scans were obtained in 64 patients (30 women, 34 men; mean age, 57 years; range, 19-86 years). The 80 PET/CT scans consisted of five group of patients (16 PET/CT scans per group) who underwent whole-body combined 18F-FDG PET/CT with different CT breathing protocols: expiration, mid suspended breath-hold, quiet breathing, small breath in, and regular breath in. The quality of alignment was analyzed at the diaphragm, aortic arch, heart, thoracic spine, and lung apices using a scale of ratings from 1 (very poor) to 5 (excellent). The Kruskal-Wallis test was used to compare alignment between breathing protocols for each anatomic reference point.RESULTS. Alignment of the PET and CT data sets was excellent with three breathing protocols: expiration, mid suspended breath-hold, and quiet breathing, with no statistical differences. Significant m...


  • Accuracy of transmission CT and FDG-PET in the detection of small pulmonary nodules with integrated PET/CT

    by Suzanne L. Aquino, Landon B. Kuester, Victorine V. Muse, Elkan F. Halpern, Alan J. Fischman

    The purpose of this study was to determine the accuracy of detection of small pulmonary nodules on quiet breathing attenuation correction CT (CTAC) and FDG-PET when performing integrated PET/CT, as compared with a diagnostic inspiratory CT scan acquired in the same imaging session. PET/CT scans of 107 patients with a history of carcinoma (54 male and 53 female, mean age 57.3 years) were analyzed. All patients received an integrated PET/CT scan including a CTAC acquired during quiet respiration and a contrast-enhanced CT acquired during inspiration in the same session. Breathing CTAC scans were reviewed by two thoracic radiologists for the presence of pulmonary nodules. FDG-PET scans were reviewed to determine accuracy of nodule detection. Diagnostic CT was used as the gold standard to confirm or refute the presence of nodules. On the CTAC scans 200 nodules were detected, of which 183 were true positive (TP) and 17, false positive. There were 109 false negatives (FN). Overall, 51 (48%) patients had a false interpretation, including 19 in whom CT was interpreted as normal for lung nodules. The average size of the nodules missed was 3.8+/-2 mm (range 2-12 mm). None of the nodules missed on the CTAC scans were detected by PET. In the right lung there were 20 TP, 42 true negative (TN), 11 FP, and 34 FN interpretations with a sensitivity in nodule detection of 37% (CI 24-51%) and a specificity of 79% (CI 66-89%). In the left lungs there were 16 TP, 65 TN, 3 FP, and 23 FN interpretations, with a sensitivity of 41% (CI 26-58%) and a specificity of 96% (CI 88-99%). The detection of small pulmonary nodules by breathing CTAC and FDG-PET is relatively poor. Therefore an additional diagnostic thoracic CT scan obtained during suspended inspiration is recommended for thorough evaluation of those patients in whom detection of pulmonary metastases is necessary for management.


  • Lipomatous Hypertrophy of the Interatrial Septum

    by Landon B. Kuester, Alan J. Fischman, Chieh-Min Fan, Elkan F. Halpern, Suzanne L. Aquino


  • Comparison of Alignment of Computer-registered Data Sets: Combined PET/CT versus Independent PET and CT of the Thorax

    by Vikram Krishnasetty, Alan J. Fischman, Elkan L. Halpern, Suzanne L. Aquino

    To retrospectively determine whether alignment of registered positron emission tomographic (PET) and computed tomographic (CT) data sets obtained independently varies significantly from alignment of data sets acquired from a combined PET/CT scanner.The study was approved by the institution's Human Research Committee with a waiver of informed consent and complied with HIPAA. Whole-body combined PET/CT data sets and separate routinely positioned thoracic CT data sets were obtained from 12 patients (six men, six women; mean age, 48.6 years; range, 24-62 years). Separate PET and thoracic CT data sets matched for patient positioning and respiration were acquired on the same day for nine patients (four men, five women; mean age, 71 years; range, 51-90 years). Computer nonlinear registration was performed on PET and CT data sets from combined PET/CT (fusion group 1), PET data sets from combined PET/CT with unmatched thoracic CT (fusion group 2), and data sets from separate PET and CT matched for patient positioning and respiration (fusion group 3). Quality of alignment was assessed by two radiologists in consensus blinded to the source of registered data in each fusion group at the following anatomic locations: diaphragm, aortic arch, heart, thoracic spine, and lung apices. Results were compared by using the Wilcoxon paired signed rank and unpaired rank sum tests.Quality of alignment did not significantly differ between fusion group 1 and fusion group 3. Fusion group 1 provided significantly better alignment in two of five anatomic locations (P = .008 for diaphragm and P = .031 for heart) than fusion group 2. Fusion group 3 provided significantly better alignment in two of five anatomic locations (P = .037 for diaphragm and P = .009 for heart) than fusion group 2.Thoracic anatomic alignment does not significantly differ between registered PET and CT data sets acquired on a combined PET/CT scanner or from separate PET and CT scanners obtained on the same day when carefully matched for anatomic positioning and respiration.


  • The Source and Direction of Thoracic Lymphatics, Part II: The Lower Thorax

    by Suzanne L. Aquino, L. Anne Hayman, Susanne L. Loomis, Katherine H. Taber

    The purpose of this set of 2 articles is to illustrate the source and direction of lymphatic drainage in the thorax on axial computed tomographic (CT) schematics. The first article describes the upper thorax. This article describes the lower thorax. The nodal groups are given conventional anatomic names and the corresponding terminology of the American Thoracic Society. Arrows indicate the direction of the flow. The region or organ drained is color-coded, and nodes that receive lymph from each area are assigned appropriately colored and numbered boxes. Major drainage patterns are also described. This information can be used to assess a suspicious lymph node by tracing it to the region of drainage and looking for pathology. Alternately, one may extrapolate the potential drainage routes of a tumor and scrutinize specific sites for nodal metastases.


  • Acquired Tracheomalacia: Detection by Expiratory CT Scan

    by Suzanne L. Aquino, Jo-Anne O. Shepard, Leo C. Ginns, Richard H. Moore, Elkan Halpern, Hermes C. Grillo, Theresa C. McLoud

    The purpose of this work was to determine whether cross-sectional area and coronal and sagittal diameter measurements of the trachea between inspiration and end-expiration on CT are significantly different between patients with acquired tracheomalacia and those without this condition. Inspiratory and end-expiratory CT scans of the trachea of 23 normal patients and 10 patients with acquired tracheomalacia were analyzed. Percent changes in cross-sectional area, coronal, and sagittal diameters were calculated. For patients with tracheomalacia, mean percent changes in the upper and middle trachea between inspiration and expiration were 49 and 44%; mean changes in the coronal and sagittal diameters in the upper and middle tracheal were 4 and 10% and 39 and 54%, respectively. Control group mean percent changes in the upper and middle tracheal area were 12 and 14%, respectively, and mean changes in the coronal and sagittal diameters in the upper and middle trachea were 4 and 4% and 11 and 13%, respectively. Significant differences were calculated for changes in cross-sectional area and sagittal diameter between groups (p < 10−5). Based on receiver operator curve analysis, a >18% change in the upper trachea and 28% change in the midtrachea between inspiration and expiration were observed; the probability of tracheomalacia was 89–100%. The probability of tracheomalacia was >89%, especially if the change in sagittal diameter was >28%. By measuring changes in tracheal cross-sectional area and sagittal diameters between inspiratory and end-expiratory CT, a significant difference can be identified between normal patients and those with acquired tracheomalacia.