Herald Rose
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Herald Rose has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Bernd Kabius
Institut für Festkörperforschung Forschungszentrum Jülich, D-52425 Jülich, Germany
1 shared publicationKnut Urban
Institut für Festkörperforschung Forschungszentrum Jülich, D-52425 Jülich, Germany
1 shared publicationMaximilian Haider
CEOS GmbH Im Neuenheimer Feld 519, D-69120 Heidelberg, Germany
1 shared publicationStephan Uhlemann
CEOS GmbH Im Neuenheimer Feld 519, D-69120 Heidelberg, Germany
1 shared publication
Latest Publications
- 1 April 2005
- Published by Elsevier in Ultramicroscopy
- Vol. 103 (1) , 1-6
Prospects for aberration-free electron microscopy
- 1 April 2005
- Published by Elsevier in Ultramicroscopy
- Vol. 103 (1) , 1-6
Prospects for aberration-free electron microscopy
- 1 August 2003
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 9 (S03) , 32-33
Outline of an Ultracorrector Compensating for all Primary Chromatic and Geometrical Aberrations of Charged-Particle Lenses
- 1 August 2003
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 9 (S03) , 32-33
Outline of an Ultracorrector Compensating for all Primary Chromatic and Geometrical Aberrations of Charged-Particle Lenses
- 1 December 2002
- Published by Elsevier in Ultramicroscopy
- Vol. 93 (3-4) , 293-303
Theory of electron-optical achromats and apochromats
- 1 December 2002
- Published by Elsevier in Ultramicroscopy
- Vol. 93 (3-4) , 293-303
Theory of electron-optical achromats and apochromats
- 1 January 1998
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 47 (5) , 395-405
Towards 0.1 nm resolution with the first spherically corrected transmission electron microscope
A hexapole corrector which compensates for the spherical aberration of the objective lens has been incorporated in a commercial 200 kV transmission electron microscope (TEM) equipped with a field emission gun. The successful correction of the spherical aberration is demonstrated by decreasing the instrumental resolution limit from 0.24 nm down to about 0.13 nm. Images of Si-SiCO2 interfaces obtained with the corrected TEM show a remarkable suppression of artefacts and a strong increase in contrast apart from the improved resolution. The design, alignment and the performance of the corrected instrument are outlined in detail.
- 1 January 1998
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 47 (5) , 395-405
Towards 0.1 nm resolution with the first spherically corrected transmission electron microscope
A hexapole corrector which compensates for the spherical aberration of the objective lens has been incorporated in a commercial 200 kV transmission electron microscope (TEM) equipped with a field emission gun. The successful correction of the spherical aberration is demonstrated by decreasing the instrumental resolution limit from 0.24 nm down to about 0.13 nm. Images of Si-SiCO2 interfaces obtained with the corrected TEM show a remarkable suppression of artefacts and a strong increase in contrast apart from the improved resolution. The design, alignment and the performance of the corrected instrument are outlined in detail.