Marco Carlone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marco Carlone has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Miller MacPherson
Radiation Medicine Program Princess Margaret Cancer Centre Toronto ON Canada
2 shared publicationsAlejandra Rangel
1 shared publicationBern Norrlinger
1 shared publication- Charmainne Cruje
Ryerson University, Canada
1 shared publication - David Anthony Jaffray
The University of Texas MD Anderson Cancer Center, Houston, TX
1 shared publication David Jaffray
1 shared publication
Latest Publications
- 17 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (6) , 2927-2932
Technical Note: Enhancing the surface dose using a weak longitudinal magnetic field
- 17 May 2016
- Published by Wiley in Medical Physics
- Vol. 43 (6) , 2927-2932
Technical Note: Enhancing the surface dose using a weak longitudinal magnetic field
- Open Access
- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 359-377
Simulation of a medical linear accelerator for teaching purposes
Simulation software for medical linear accelerators that can be used in a teaching environment was developed. The components of linear accelerators were modeled to first order accuracy using analytical expressions taken from the literature. The expressions used constants that were empirically set such that realistic response could be expected. These expressions were programmed in a MATLAB environment with a graphical user interface in order to produce an environment similar to that of linear accelerator service mode. The program was evaluated in a systematic fashion, where parameters affecting the clinical properties of medical linear accelerator beams were adjusted independently, and the effects on beam energy and dose rate recorded. These results confirmed that beam tuning adjustments could be simulated in a simple environment. Further, adjustment of service parameters over a large range was possible, and this allows the demonstration of linear accelerator physics in an environment accessible to both medical physicists and linear accelerator service engineers. In conclusion, a software tool, named SIMAC, was developed to improve the teaching of linear accelerator physics in a simulated environment. SIMAC performed in a similar manner to medical linear accelerators. The authors hope that this tool will be valuable as a teaching tool for medical physicists and linear accelerator service engineers.PACS number: 87.55Gh, 87.56bd
- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 359-377
Open AccessSimulation of a medical linear accelerator for teaching purposes
Simulation software for medical linear accelerators that can be used in a teaching environment was developed. The components of linear accelerators were modeled to first order accuracy using analytical expressions taken from the literature. The expressions used constants that were empirically set such that realistic response could be expected. These expressions were programmed in a MATLAB environment with a graphical user interface in order to produce an environment similar to that of linear accelerator service mode. The program was evaluated in a systematic fashion, where parameters affecting the clinical properties of medical linear accelerator beams were adjusted independently, and the effects on beam energy and dose rate recorded. These results confirmed that beam tuning adjustments could be simulated in a simple environment. Further, adjustment of service parameters over a large range was possible, and this allows the demonstration of linear accelerator physics in an environment accessible to both medical physicists and linear accelerator service engineers. In conclusion, a software tool, named SIMAC, was developed to improve the teaching of linear accelerator physics in a simulated environment. SIMAC performed in a similar manner to medical linear accelerators. The authors hope that this tool will be valuable as a teaching tool for medical physicists and linear accelerator service engineers.PACS number: 87.55Gh, 87.56bd
- 7 August 2014
- Published by Wiley in Medical Physics
- Vol. 41 (8) , 25
Sci-Fri PM: Topics - 05: Experience with linac simulation software in a teaching environment
- 7 August 2014
- Published by Wiley in Medical Physics
- Vol. 41 (8) , 25
Sci-Fri PM: Topics - 05: Experience with linac simulation software in a teaching environment
- 2 April 2013
- Published by Wiley in Medical Physics
- Vol. 40 (4) , 042103
ROC analysis in patient specific quality assurance
Purpose:: This work investigates the use of receiver operating characteristic (ROC) methods in patient specific IMRT quality assurance (QA) in order to determine unbiased methods to set threshold criteria forγ‐distance to agreement measurements.Methods:: A group of 17 prostate plans was delivered as planned while a second group of 17 prostate plans was modified with the introduction of random multileaf collimator (MLC) position errors that are normally distributed withσ∼±0.5, ±1.0, ±2.0, and ±3.0 mm (a total of 68 modified plans were created). All plans were evaluated using five differentγ‐criteria. ROC methodology was applied by quantifying the fraction of modified plans reported as “fail” and unmodified plans reported as “pass.”Results:: γ‐based criteria were able to attain nearly 100% sensitivity/specificity in the detection of large random errors (σ> 3 mm). Sensitivity and specificity decrease rapidly for allγ‐criteria as the size of error to be detected decreases below 2 mm. Predictive power is null with all criteria used in the detection of small MLC errors (σ< 0.5 mm). Optimal threshold values were established by determining which criteria maximized sensitivity and specificity. For 3%/3 mmγ‐criteria, optimal threshold values range from 92% to 99%, whereas for 2%/2 mm, the range was from 77% to 94%.Conclusions:: The optimal threshold values that were determined represent a maximized test sensitivity and specificity and are not subject to any user bias. When applied to the datasets that we studied, our results suggest the use of patient specific QA as a safety tool that can effectively prevent large errors (e.g.,σ> 3 mm) as opposed to a tool to improve the quality of IMRT delivery.
- 2 April 2013
- Published by Wiley in Medical Physics
- Vol. 40 (4) , 042103
ROC analysis in patient specific quality assurance
Purpose:: This work investigates the use of receiver operating characteristic (ROC) methods in patient specific IMRT quality assurance (QA) in order to determine unbiased methods to set threshold criteria forγ‐distance to agreement measurements.Methods:: A group of 17 prostate plans was delivered as planned while a second group of 17 prostate plans was modified with the introduction of random multileaf collimator (MLC) position errors that are normally distributed withσ∼±0.5, ±1.0, ±2.0, and ±3.0 mm (a total of 68 modified plans were created). All plans were evaluated using five differentγ‐criteria. ROC methodology was applied by quantifying the fraction of modified plans reported as “fail” and unmodified plans reported as “pass.”Results:: γ‐based criteria were able to attain nearly 100% sensitivity/specificity in the detection of large random errors (σ> 3 mm). Sensitivity and specificity decrease rapidly for allγ‐criteria as the size of error to be detected decreases below 2 mm. Predictive power is null with all criteria used in the detection of small MLC errors (σ< 0.5 mm). Optimal threshold values were established by determining which criteria maximized sensitivity and specificity. For 3%/3 mmγ‐criteria, optimal threshold values range from 92% to 99%, whereas for 2%/2 mm, the range was from 77% to 94%.Conclusions:: The optimal threshold values that were determined represent a maximized test sensitivity and specificity and are not subject to any user bias. When applied to the datasets that we studied, our results suggest the use of patient specific QA as a safety tool that can effectively prevent large errors (e.g.,σ> 3 mm) as opposed to a tool to improve the quality of IMRT delivery.
- 1 December 2011
- Published by Elsevier in Medical Dosimetry
- Vol. 36 (4) , 429-433
Compensation of Missed Fractions Without Knowledge of Radiobiological Parameters
- 1 December 2011
- Published by Elsevier in Medical Dosimetry
- Vol. 36 (4) , 429-433
Compensation of Missed Fractions Without Knowledge of Radiobiological Parameters