Uta Kuepper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Uta Kuepper has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Burkhard Madea
University of Bonn
3 shared publicationsFrank Musshoff
University of Bonn
3 shared publicationsBenno Hartung
Institute of Legal Medicine, University Hospital Essen, Essen, Germany
2 shared publicationsFrank Herbstreit
Universität Duisburg-Essen and Universitätsklinikum Essen
2 shared publicationsB. Madea
Universitätsklinikum Bonn
1 shared publicationF. Mußhoff
Universitätsklinikum Bonn
1 shared publication
Latest Publications
- Open Access
- 29 June 2026
- Published by Springer Nature in International journal of legal medicine
- Vol. 140 (6) , 1-15
Observer bias in medical evaluations: a critical pre-analytical factor impacting the quality of judicial evidence in forensic-toxicological casework
This study investigates observer variability and systematic bias in medical examinations conducted during forensic blood sampling. The analysis focused on 14 experienced contract physicians routinely employed by law enforcement, a cohort expected to provide the highest degree of diagnostic reliability. In total, raw data from 1458 medical examinations were numerically coded and evaluated. Nine of the 14 physicians demonstrated signs of systematic bias, characterized by over- or underreporting of impairment symptoms compared to the peer group. Furthermore, a complete lack of (or only highly restricted) correlation between the clinical assessment of impairment and the analytical blood alcohol concentration (BAC) was observed in six practitioners. Adherence to standardized test batteries was equally inconsistent; four physicians completely omitted at least one diagnostically critical motoric test (either explicitly stated or implied), while three others significantly exceeded the average omission rates of the peer group. Despite state-of-the-art laboratory analytics, these findings indicate that - even among experienced physicians – the forensic utility of the medical report is significantly limited in approximately 40% of cases and entirely useless in an additional 10%. Given the high judicial regard for medical assessments over police observations, this lack of standardization undermines the principle of equal treatment. Furthermore, it hinders research into substance-related safety thresholds. Following the successful optimization of laboratory standards and police training, it is imperative to standardize the medical assessment process through specialized qualifications und proficiency testing. Special consideration should be given to using police bodycam recordings for objective forensic reviews, at least if a criminal offense is suspected.
- 29 June 2026
- Published by Springer Nature in International journal of legal medicine
- Vol. 140 (6) , 1-15
Open AccessObserver bias in medical evaluations: a critical pre-analytical factor impacting the quality of judicial evidence in forensic-toxicological casework
This study investigates observer variability and systematic bias in medical examinations conducted during forensic blood sampling. The analysis focused on 14 experienced contract physicians routinely employed by law enforcement, a cohort expected to provide the highest degree of diagnostic reliability. In total, raw data from 1458 medical examinations were numerically coded and evaluated. Nine of the 14 physicians demonstrated signs of systematic bias, characterized by over- or underreporting of impairment symptoms compared to the peer group. Furthermore, a complete lack of (or only highly restricted) correlation between the clinical assessment of impairment and the analytical blood alcohol concentration (BAC) was observed in six practitioners. Adherence to standardized test batteries was equally inconsistent; four physicians completely omitted at least one diagnostically critical motoric test (either explicitly stated or implied), while three others significantly exceeded the average omission rates of the peer group. Despite state-of-the-art laboratory analytics, these findings indicate that - even among experienced physicians – the forensic utility of the medical report is significantly limited in approximately 40% of cases and entirely useless in an additional 10%. Given the high judicial regard for medical assessments over police observations, this lack of standardization undermines the principle of equal treatment. Furthermore, it hinders research into substance-related safety thresholds. Following the successful optimization of laboratory standards and police training, it is imperative to standardize the medical assessment process through specialized qualifications und proficiency testing. Special consideration should be given to using police bodycam recordings for objective forensic reviews, at least if a criminal offense is suspected.
- Open Access
- 27 April 2026
- Published by Springer Nature in Rechtsmedizin
- Vol. 36 (3) , 135-145
Abgleich der Ergebnisse polizeilicher Routinevortests mit Blutanalysen: eine retrospektive Auswertung von Verkehrsfällen aus der Rechtsmedizin Essen
Zusammenfassung: Diese retrospektive Analyse untersuchte die Übereinstimmung der Ergebnisse polizeilicher Routinevortests auf Drogen in Speichel/Mundhöhlenflüssigkeit („oral fluid“/OF-VT) bzw. Urin (Urin-VT) mit denen der juristisch relevanten Blutprobenanalysen im Kontext von Verkehrskontrollen. Untersucht wurden 3570 abgeschlossene Verkehrsfälle vom 01.08.2023 bis Mitte November 2025. In fast der Hälfte aller Fälle, in denen ein Vortest durchgeführt wurde, war mindestens einer der getesteten Parameter diskrepant zum Ergebnis der späteren Blutprobe: Den neuen THC-Grenzwert (§ 24a StVG) von 3,5 ng/ml im Serum zugrunde gelegt, ergab sich in ca. 47 % der Fälle mit OF-VT und in ca. 48 % der Fälle mit Urin-VT zumindest eine Abweichung zur Befundkonstellation der entsprechenden Blutprobe. Die Diskrepanzquoten waren dabei bereits nach dem alten THC-Grenzwert von 1,0 ng/ml hoch (OF-VT: 39 %, Urin-VT: 33 %), so dass die Grenzwertanhebung nicht als maßgeblicher Treiber für die beobachteten Abweichungen gesehen werden kann. Die Hauptursachen können dagegen primär in vortestimmanenten Problemen wie dem zwingenden Matrixwechsel, der Zeitdifferenz zwischen Vortest und Blutentnahme sowie der geringen Spezifität immunchemischer Verfahren verortet werden. Auch Anwender- bzw. Dokumentationsfehler haben einen relevanten Einfluss auf die apparente Treffgenauigkeit der Vortests. Im Vergleich der beiden Vorteststrategien zeigte sich ein relativ ausgewogenes Vor‑/Nachteilprofil: Der Urin-VT ist dem OF-VT bezüglich falsch-positiver (FP) Amphetaminbefunde (5 % weniger) und der Rate falsch-negativer (FN) Ergebnisse für „harte“ Drogen überlegen, weist jedoch fast 5 % mehr FP-Ergebnisse für THC (ausgewertet nach dem neuen Grenzwert von 3,5 ng/ml) auf. Das Risiko von Dokumentations- bzw. Anwenderfehlern war beim OF-VT eher zu erkennen als beim Urin-VT. Die Ergebnisse unterstreichen, dass polizeiliche Vortests nur als Ergänzung zur qualifizierten Drogenerkennung dienen können und keinen Ersatz für diese darstellen.
- 27 April 2026
- Published by Springer Nature in Rechtsmedizin
- Vol. 36 (3) , 135-145
Open AccessAbgleich der Ergebnisse polizeilicher Routinevortests mit Blutanalysen: eine retrospektive Auswertung von Verkehrsfällen aus der Rechtsmedizin Essen
Zusammenfassung: Diese retrospektive Analyse untersuchte die Übereinstimmung der Ergebnisse polizeilicher Routinevortests auf Drogen in Speichel/Mundhöhlenflüssigkeit („oral fluid“/OF-VT) bzw. Urin (Urin-VT) mit denen der juristisch relevanten Blutprobenanalysen im Kontext von Verkehrskontrollen. Untersucht wurden 3570 abgeschlossene Verkehrsfälle vom 01.08.2023 bis Mitte November 2025. In fast der Hälfte aller Fälle, in denen ein Vortest durchgeführt wurde, war mindestens einer der getesteten Parameter diskrepant zum Ergebnis der späteren Blutprobe: Den neuen THC-Grenzwert (§ 24a StVG) von 3,5 ng/ml im Serum zugrunde gelegt, ergab sich in ca. 47 % der Fälle mit OF-VT und in ca. 48 % der Fälle mit Urin-VT zumindest eine Abweichung zur Befundkonstellation der entsprechenden Blutprobe. Die Diskrepanzquoten waren dabei bereits nach dem alten THC-Grenzwert von 1,0 ng/ml hoch (OF-VT: 39 %, Urin-VT: 33 %), so dass die Grenzwertanhebung nicht als maßgeblicher Treiber für die beobachteten Abweichungen gesehen werden kann. Die Hauptursachen können dagegen primär in vortestimmanenten Problemen wie dem zwingenden Matrixwechsel, der Zeitdifferenz zwischen Vortest und Blutentnahme sowie der geringen Spezifität immunchemischer Verfahren verortet werden. Auch Anwender- bzw. Dokumentationsfehler haben einen relevanten Einfluss auf die apparente Treffgenauigkeit der Vortests. Im Vergleich der beiden Vorteststrategien zeigte sich ein relativ ausgewogenes Vor‑/Nachteilprofil: Der Urin-VT ist dem OF-VT bezüglich falsch-positiver (FP) Amphetaminbefunde (5 % weniger) und der Rate falsch-negativer (FN) Ergebnisse für „harte“ Drogen überlegen, weist jedoch fast 5 % mehr FP-Ergebnisse für THC (ausgewertet nach dem neuen Grenzwert von 3,5 ng/ml) auf. Das Risiko von Dokumentations- bzw. Anwenderfehlern war beim OF-VT eher zu erkennen als beim Urin-VT. Die Ergebnisse unterstreichen, dass polizeiliche Vortests nur als Ergänzung zur qualifizierten Drogenerkennung dienen können und keinen Ersatz für diese darstellen.
- 5 September 2012
- Published by Springer Nature in Rechtsmedizin
- Vol. 22 (5) , 415-430
Succinylcholin in der forensischen Toxikologie
- 5 September 2012
- Published by Springer Nature in Rechtsmedizin
- Vol. 22 (5) , 415-430
Succinylcholin in der forensischen Toxikologie
- 24 September 2011
- Published by Springer Nature in International journal of legal medicine
- Vol. 126 (2) , 259-269
Degradation and elimination of succinylcholine and succinylmonocholine and definition of their respective detection windows in blood and urine for forensic purposes
The muscle relaxant succinylcholine (SUX) evokes respiratory paralysis, and numerous cases of fatal SUX intoxication have been reported. Detection of SUX and its metabolite succinylmonocholine (SMC) is difficult, both due to their (bis-) quaternary structure and the extreme hydrolytic susceptibility of SUX, and data on degradation kinetics of SUX and SMC is scarce. The present study investigates the in vivo and in vitro degradation as well as elimination of both target analytes using authentic blood and urine samples from anesthetized patients. With a special focus on the urinary data and stabilization issues, this work intends to considerably enhance the forensic knowledge concerning SUX intoxications and to present the reader with practical analytical strategies to cope with such difficult cases. Eighteen subjects undergoing surgery and requiring arterial as well as bladder catheters were included in this study. Muscle relaxation was initialized with a bolus injection of 80–100 mg SUX. Blood and urine samples were either collected using paraoxonized (n = 15) or non-modified (n = 3) tubes. Sampling was performed within 6 h after SUX application following a pre-assigned schedule. Samples were processed according to a validated isotope dilution HPLC–MS/MS method using ion-pair solid-phase extraction. In blood, SUX was usually detectable for up to 10 min post-injection, while detection of SMC was possible over the whole observation period of 6 h. Effectiveness of organophosphate stabilization was proven for both analytes and is therefore recommended. In freshly secreted urine, detection windows of a minimum of 2 h as opposed to 6 h have been determined for SUX versus SMC, respectively. Considering SMC plasma kinetics, detection of the metabolite in blood and freshly secreted urine appears to be possible over a period of at least 8–24 h. Paraoxon did not enhance the stability of either target substance in urine, stabilization of urine samples is nonetheless recommended. In summary, SMC was proven to be the most promising target analyte in SUX analysis, with urine being the proposed matrix of choice for forensic applications. Furthermore, our work defines meaningful detection windows for SUX and SMC in blood and urine as routine matrices and presents sampling recommendations as well as guideline values for forensic toxicological analysis.
- 24 September 2011
- Published by Springer Nature in International journal of legal medicine
- Vol. 126 (2) , 259-269
Degradation and elimination of succinylcholine and succinylmonocholine and definition of their respective detection windows in blood and urine for forensic purposes
The muscle relaxant succinylcholine (SUX) evokes respiratory paralysis, and numerous cases of fatal SUX intoxication have been reported. Detection of SUX and its metabolite succinylmonocholine (SMC) is difficult, both due to their (bis-) quaternary structure and the extreme hydrolytic susceptibility of SUX, and data on degradation kinetics of SUX and SMC is scarce. The present study investigates the in vivo and in vitro degradation as well as elimination of both target analytes using authentic blood and urine samples from anesthetized patients. With a special focus on the urinary data and stabilization issues, this work intends to considerably enhance the forensic knowledge concerning SUX intoxications and to present the reader with practical analytical strategies to cope with such difficult cases. Eighteen subjects undergoing surgery and requiring arterial as well as bladder catheters were included in this study. Muscle relaxation was initialized with a bolus injection of 80–100 mg SUX. Blood and urine samples were either collected using paraoxonized (n = 15) or non-modified (n = 3) tubes. Sampling was performed within 6 h after SUX application following a pre-assigned schedule. Samples were processed according to a validated isotope dilution HPLC–MS/MS method using ion-pair solid-phase extraction. In blood, SUX was usually detectable for up to 10 min post-injection, while detection of SMC was possible over the whole observation period of 6 h. Effectiveness of organophosphate stabilization was proven for both analytes and is therefore recommended. In freshly secreted urine, detection windows of a minimum of 2 h as opposed to 6 h have been determined for SUX versus SMC, respectively. Considering SMC plasma kinetics, detection of the metabolite in blood and freshly secreted urine appears to be possible over a period of at least 8–24 h. Paraoxon did not enhance the stability of either target substance in urine, stabilization of urine samples is nonetheless recommended. In summary, SMC was proven to be the most promising target analyte in SUX analysis, with urine being the proposed matrix of choice for forensic applications. Furthermore, our work defines meaningful detection windows for SUX and SMC in blood and urine as routine matrices and presents sampling recommendations as well as guideline values for forensic toxicological analysis.
- Open Access
- 1 June 2011
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 35 (5) , 302-311
Pharmacokinetic Properties of Succinylmonocholine in Surgical Patients
Intoxications with succinylcholine (SUX) lead to a potentially lethal respiratory paralysis, and forensic cases involving accidental or deliberate SUX-application have been reported. Detection of SUX as well as its metabolite succinylmonocholine (SMC) is difficult: both substances are analytically challenging, and the extremely short plasma half-life of SUX additionally hampers detection of the parent compound. Pharmacokinetic data are scarce on SUX and non-existent on SMC. To enhance forensic knowledge concerning SUX intoxications, plasma pharmacokinetics of SMC were investigated in anesthetized patients. Fifteen subjects scheduled for a surgical procedure were included in this study. Muscle-relaxation was initialized with a bolus injection of 80–100 mg SUX. Blood sampling was performed within 6 h after SUX application using paraoxonized tubes. Collected plasma was processed according to a validated isotope dilution high-performance liquid chromatography-tandem mass spectrometry method using ion-pair solid-phase extraction. Pharmacokinetic parameters were derived from a user-defined as well as a three-compartment model. For SMC, peak plasma concentrations were reached after 0.03–2.0 min. In contrast to SUX, SMC was more slowly and more extensively distributed, featuring triphasic plasma concentration time profiles. Pharmacokinetic key parameters were subject to interindividual variation of potential forensic importance, with terminal half-lives of 1—3 h indicating a detection interval of 8–24 h for SMC in plasma. SMC was proven to be the only realistic SUX marker in a forensic context. The present work defines meaningful detection windows for plasmatic SMC after SUX application and offers guideline values for forensic toxicological casework.
- 1 June 2011
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 35 (5) , 302-311
Open AccessPharmacokinetic Properties of Succinylmonocholine in Surgical Patients
Intoxications with succinylcholine (SUX) lead to a potentially lethal respiratory paralysis, and forensic cases involving accidental or deliberate SUX-application have been reported. Detection of SUX as well as its metabolite succinylmonocholine (SMC) is difficult: both substances are analytically challenging, and the extremely short plasma half-life of SUX additionally hampers detection of the parent compound. Pharmacokinetic data are scarce on SUX and non-existent on SMC. To enhance forensic knowledge concerning SUX intoxications, plasma pharmacokinetics of SMC were investigated in anesthetized patients. Fifteen subjects scheduled for a surgical procedure were included in this study. Muscle-relaxation was initialized with a bolus injection of 80–100 mg SUX. Blood sampling was performed within 6 h after SUX application using paraoxonized tubes. Collected plasma was processed according to a validated isotope dilution high-performance liquid chromatography-tandem mass spectrometry method using ion-pair solid-phase extraction. Pharmacokinetic parameters were derived from a user-defined as well as a three-compartment model. For SMC, peak plasma concentrations were reached after 0.03–2.0 min. In contrast to SUX, SMC was more slowly and more extensively distributed, featuring triphasic plasma concentration time profiles. Pharmacokinetic key parameters were subject to interindividual variation of potential forensic importance, with terminal half-lives of 1—3 h indicating a detection interval of 8–24 h for SMC in plasma. SMC was proven to be the only realistic SUX marker in a forensic context. The present work defines meaningful detection windows for plasmatic SMC after SUX application and offers guideline values for forensic toxicological casework.