KTKai Tang

Kai Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kai Tang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Andreas Braun

    Sequenom Inc., 11555 Sorrento Valley Road, San Diego, CA 92121

    1 shared publication
  • Benjamin A. Garcia

    Sequenom Inc., 3595 John Hopkins Court, San Diego, CA 92121, USA and 2Center for Advanced Biotechnology, Boston University, Boston, MA 02215, USA

    1 shared publication
  • Charles R. Cantor

    Sequenom Inc., 11555 Sorrento Valley Road, San Diego, CA 92121

    1 shared publication
  • Dominique Julien

    Sequenom Inc., 11555 Sorrento Valley Road, San Diego, CA 92121

    1 shared publication
  • Dong-Jing Fu

    Sequenom Inc., 11555 Sorrento Valley Road, San Diego, CA 92121

    1 shared publication
  • Hubert Köster

    Sequenom Inc., 11555 Sorrento Valley Road, San Diego, CA 92121

    1 shared publication

Latest Publications

  • Sugar additives for MALDI matrices improve signal allowing the smallest nucleotide change (A:T) in a DNA sequence to be resolved

    by Mona Shahgholi, Benjamin A. Garcia, Norman H. L. Chiu, Paul J. Heaney, Kai Tang

    Sample preparation for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) of DNA is critical for obtaining high quality mass spectra. Sample impurity, solvent content, substrate surface and environmental conditions (temperature and humidity) all affect the rate of matrix-analyte co-crystallization. As a result, laser fluence threshold for desorption/ionization varies from spot to spot. When using 3-hydroxypicolinic acid (3-HPA) as the matrix, laser fluence higher than the threshold value reduces mass resolution in time-of-flight (TOF) MS as the excess energy transferred to DNA causes metastable decay. This can be overcome by either searching for 'hot' spots or adjusting the laser fluence. However, both solutions may require a significant amount of operator manipulation and are not ideal for automatic measurements. We have added various sugars for crystallization with the matrix to minimize the transfer of excess laser energy to DNA molecules. Fructose and fucose were found to be the most effective matrix additives. Using these additives, mass resolution for DNA molecules does not show noticeable deterioration as laser energy increases. Improved sample preparation is important for the detection of single nucleotide polymorphisms (SNPs) using primer extension with a single nucleotide. During automatic data acquisition it is difficult to routinely detect heterozygous A/T mutations, which requires resolving a mass difference of 9 Da, unless a sugar is added during crystallization.


  • Open Access

    Chip-based genotyping by mass spectrometry

    by Kai Tang, Dong-Jing Fu, Dominique Julien, Andreas Braun, Charles R. Cantor, Hubert Köster

    Silicon chips with immobilized target DNAs were used for accurate genotyping by mass spectrometry. Genomic DNAs were amplified with PCR, and the amplified products were covalently attached to chip wells via N -succinimidyl (4-iodoacetyl)aminobenzoate (SIAB) chemistry. Primer annealing, extension, and termination were performed on a 1-μl scale directly in the chip wells in parallel. Diagnostic products thus generated were detected in situ by using matrix-assisted laser desorption ionization mass spectrometry. This miniaturized method has the potential for accurate, high-throughput, low-cost identification of genetic variations.