RBRené Hubert Bombien

René Hubert Bombien

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


René Hubert Bombien has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Georg Lutter

    Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany

    3 shared publications
  • Lucian Lozonschi

    Divison of Cardiothoracic Surgery, University of Wisconsin School of Medicine, Madison, WI, USA

    3 shared publications
  • Michael Schünke

    Institute of Anatomy, Christian-Albrechts-University of Kiel, Kiel, Germany

    3 shared publications
  • Georg Lutter

    Department of Cardiovascular Surgery, Christian-Albrechts-University of Kiel, School of Medicine, Kiel, Germany

    2 shared publications
  • Jochen Cremer

    2 shared publications
  • Christian Dahmen

    Division Microrobotics and Control Engineering, University of Oldenburg, Oldenburg, GERMANY

    1 shared publication

Latest Publications

  • Open Access

    Transcatheter aortic valve replacement: transapical resection of the aortic valve in vivo

    by RenÉ Bombien Quaden, Monika Leester-Schaedel, Lucian Lozonschi, Georg Lutter

    The resection of pulmonary valves has already been demonstrated in an experimental beating-heart model. The aim of this study was to analyse the transapical laser-assisted resection of aortic valves in an in vivo porcine model in a non-beating heart. The resection was performed in a porcine model (n = 10) using a Thullium:YAG laser. After establishing a standard extracorporeal circulatory support, the aortic valve isolation chamber (AVIC) system was inserted transapically. The resection of the aortic leaflets was carried out step-by-step in the arrested heart. The AVIC implantation, the resection process, and the gross anatomy of intracardiac lesions were analysed. The procedure for installing the AVIC took 5.8 ± 1.5 min. A sealed chamber was achieved in 9/10 cases. The resection of the valves was performed in 8/10 and completed in 7/10 cases. The resection took, on average, 7.4 ± 2.7 min/cusp. In 9/10 cases, the sealing was sufficient. Gross anatomy and histological analysis demonstrated only superficial damage to the surrounding tissue. In this study, the in vivo on-pump isolation of the left ventricular outflow tract and the laser resection of the native aortic valve could be demonstrated successfully. Nevertheless, this model is the next step towards a beating-heart resection of the aortic valve using the isolation chamber.


  • Open Access

    Transcatheter valve implantation: damage to the human aorta after valved stent delivery system exposure—an in vitro study

    by Paul Philipp Heinisch, Oliver Richter, Michael SchÜNke, Rene Bombien Quaden

    Transcatheter heart valve implantation can be performed transapically and transfemorally. The transfemoral way to the aortic valve is significantly longer than the transapical one. The aim of this study was to analyse the intima of 15 human aortas after the deployment of different conventional valved stent delivery systems. Fifteen human aortas have been analysed (77 ± 8.4 years). These aortas were preserved with formalin and explanted from the common iliac arteries to the ascending aorta. After protocolling all relevant vascular parameters, the deployment force of different conventional valved stent delivery systems was analysed. After that, the intima was closely investigated by endoscopy. The deployment force of the old catheter was not different from the actual system. The endoscopic investigation revealed significant intimal damages in all parts of the aorta after deployment of the delivery system. This study demonstrated that the passage to the aortic valve can result in significant intimal damage regardless of the used deployment catheter. Efforts are necessary to lower the profile of the deployment devices to increase their flexibility. The intima of the aorta and possible damage have to get back into the physicians' focus to avoid possible late aortic complications.


  • Open Access

    Percutaneous Aortic Valve Replacement

    by René Bombien, Claudia Lesche, Lucian Lozonschi, Max Feucker, Ralf Brinkmann, Christian Dahmen, Michael Schünke, Jochen Cremer, Georg Lutter

    The feasibility of endovascular resection of highly calcified aortic valves has already been demonstrated by our group. Different endovascular and intracardiac tractability methods were applied. In this study, these technologies were analyzed comparing the tractability, the resection time, and the lesions in the surrounding tissue. All aortic valve resections (seven human hearts and 21 porcine hearts) were performed using a Thulium:YAG laser (continuous wave, wavelength of 2.01 μm, 20 watts power rating). In the first resection system, the laser fiber was controlled by a free in-lying flexible endoscope (Ø 2.5 mm, length of 600 mm). The distal part of the endoscope (40 mm) was moved in one plane by proximal manual control (three degrees of freedom). The resection system was separated into defined rooms assigning one room for one tool. The fiber was controlled by the above-mentioned endoscope (*) (three degrees of freedom). The third resection system was a mechanical microactuator carrying the laser fiber (three degrees of freedom). The fourth resection system contains a rotatable inlay with defined rooms and a newly designed nitinol (NiTi) microactuator that controlled the laser fiber (four degrees of freedom). The resection time per leaflet was measured in minutes. Gross anatomy and histology in the surrounding tissue were evaluated. The resection time in approaches 1, 2, 3, and 4 was 5.5 ± 2.3 minutes, 7.4 ± 2.7 minutes, ± 6.6 minutes, and2.3 ± 1.2 minutes, respectively. The gross anatomy and histology of collateral damages revealed only superficial lesions of the surrounding tissue. The amount of lesions and the resection time were lower in the fourth approach with four degrees of freedom. This analysis demonstrated that a precise tractability with four degrees of freedom is necessary for a faster and safer endovascular resection of the aortic valve. The analysis will help to optimize the ongoing development of the endovascular and intra-cardiac resection technology.


  • Open Access

    Percutaneous aortic valve replacement: computed tomography scan after valved stent implantation in human cadaver hearts

    by René Bombien, Tim Hümme, Michael Schünke, Georg Lutter

    Computed tomography scans were performed before and after aortic valve resection with consecutive implantation of a valved stent in human hearts with highly calcified aortic valves in situ (n = 2). This demonstrates that the valved stent shows better fitting in the annulus after removal of the native valve.


  • Open Access

    Percutaneous aortic valve replacement: gross anatomy and histological findings after transapical and endoluminal resection of human aortic valves in situ???

    by René Hubert Bombien, Marie Appel, Tim Attmann, Günter-Rudolf Klaws, Michael Schünke, Christine Haß, Jochen Cremer, Georg Lutter

    Objective: Transluminal resection of the aortic valve was already successfully carried out by our group. The aim of this study was the analysis of the gross anatomy and the histology of the surrounding tissue after resection. Methods: Aortic valve resection was performed in postmortem human hearts (endoluminal (EL) n = 9, transapical (TA) n = 4). After deployment of the aortic valve isolation chamber, the leaflets were resected with a Thullium:YAG laser scalpel (cw, 20 W). After resection, the hearts were analyzed to check for lesions caused by resectioning the associated tools. Therefore, gross anatomy and histological analysis were performed (H&E staining). Results: Lesions of the aortic annulus were seen in 3/9 (EL) (depth: 583 ± 186 μm) and 2/4 (TA) (120 μm and one complete perforation), lesions of the aorta (ascending-arch-descending) in 4-9-0/9 (EL) and 0-0-0/4 (TA), lesions of the mitral valve in 0/9 (EL) and 0/4 (TA), lesions of the papillary muscle in 0/9 (EL) and 2/4 (TA) (depth: 400 μm and 450 μm), lesions of the endomyocardium in 0/9 (EL) and 4/4 (TA) (depth: 258 ± 102 μm). The coronary ostia remained unaffected. Conclusions: This study shows fewer severe lesions in the aorta after transapical antegrade access compared to the transluminal retrograde approach. Especially noteworthy is that the aortic arch remains unaffected by the transapical procedure. These data demonstrate the transapical approach as less hazardous.