OHOliver Hupe

Oliver Hupe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oliver Hupe has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 25 years of EURADOS working group 2 ‘harmonisation of individual monitoring in Europe’

    by Marie-Anne Chevallier, Oliver Hupe, João Alves, Janwillem van Dijk, David T Bartlett, Elena Fantuzzi, Phil Gilvin, Hannes Stadtmann, Vasiliki Kamenopoulou, Raul M Garcia

    April 2022: The International Conference on Individual Monitoring of Ionising Radiation (IM2022), the first live conference after the COVID pandemic, provided a renewed opportunity to discuss again with colleagues and share new information about individual monitoring, how we solve our common problems by research studies, new methodologies... This desire, this need to share common problems around this theme does not date from yesterday. It was born 25 y ago in Brussels on 28 April 1997, during the first plenary meeting of a concerted EURADOS action called ‘Harmonisation and dosimetric quality assurance in individual monitoring for external radiation’. That event represented the start of a new working group in EURADOS: WG2, which aims to foster harmonisation in individual monitoring for external radiation. EURADOS, in December 1996, set up an Action entitled ‘Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation’. The main objectives of this Action were to assist the consolidation within the EU of the quality of individual monitoring using personal dosemeters and to facilitate harmonised procedures. In order to meet these objectives an Action Group was set up, chaired by David Bartlett (NRPB) and comprising members from each of the EU Member States plus Switzerland. Sub-groups were formed to carry out each of three tasks and prepare a report, assisted by all members of the Action Group. The meetings of the EURADOS Action Group were supported by the European Commission, Directorate General XII, Science Research and Development, under the Nuclear Fission Safety—Reactor Safety, Waste Management and Radiation Protection, Framework Programme (FP) 1994–1998, contract number F14P-CT96-0061


  • Open Access

    What Is Worth Knowing in Interventional Practices about Medical Staff Radiation Exposure Monitoring: A Review of Recent Outcomes of EURADOS Working Group 12

    by Paolo Ferrari, Mercè Ginjaume, Oliver Hupe, Una O’connor, Filip Vanhavere, Elena Bakhanova, Frank Becker, Lorenzo Campani, Eleftheria Carinou, Isabelle Clairand, et al.

    EURADOS (European Radiation Dosimetry Group) Working Group 12 (WG12) SG1 activities are aimed at occupational radiation protection and individual monitoring in X-ray and nuclear medicine practices. In recent years, many studies have been carried out in these fields, especially for interventional radiology and cardiology workplaces (IC/IR). The complexity of the exposure conditions of the medical staff during interventional practices makes the radiation protection and monitoring of the exposed workers a challenging task. The scope of the present work is to review some of the main results obtained within WG12 activities about scattered field characterization and personal dosimetry that could be very useful in increasing the quality of radiation protection of the personnel, safety, and awareness of radiation risk. Two papers on Monte Carlo modelling of interventional theater and three papers on active personal dosimeters (APDs) for personnel monitoring were considered in the review. More specifically, Monte Carlo simulation was used as the main tool to characterize the levels of exposure of the medical staff, allowing to determine how beam energy and direction can have an impact on the doses received by the operators. Indeed, the simulations provided information about the exposure of the operator’s head, and the study concluded with the determination of an eye-lens protection factor when protection goggles and a ceiling shielding are used. Moreover, the review included the results of studies on active personal dosimeters, their use in IC/IR workplaces, and how they respond to calibration fields, with X-ray standard and pulsed beams. It was shown that APDs are insensitive to backscatter radiation, but some of them could not respond correctly to the very intense pulsed fields (as those next to the patient in interventional practices). The measurements during interventional procedures showed the potential capability of the employment of APDs in hospitals.


  • DEVELOPMENT OF A NEW SECONDARY STANDARD FOR H*(10)

    by K Bairlein, B Behnke, O Hupe

    A secondary standard for ambient dose equivalent, H*(10), is necessary for the dissemination of the unit Sievert (Sv), but there is no such standard commercially available currently. Furthermore, the measurement of H*(10) instead of calculating H*(10) from air kerma and conversion coefficients is needed for unknown radiation fields. We developed a prototype of a new secondary standard for H*(10) based on a spherical 1 l ionization chamber for air kerma. This chamber was modified with copper wires at the inner surface to adjust the response of the chamber according to H*(10). Additionally, a Makrolon shell and an aluminium coating were added to optimize the response at energies below 50 keV. The prototype fulfils the requirements given in ISO 4037-2 in the energy range from 12 keV to 7 MeV. In combination with an electrometer, it can be used as area dosemeter, suitable for pulsed fields and for low energy radiation.


  • TESTING DIFFERENT AREA DOSEMETERS CONCERNING THEIR BEHAVIOUR IN PULSED RADIATION FIELDS

    by Sabrina Friedrich, Oliver Hupe

    In Germany, authorised experts are required to measure around an X-ray facility to determine supervised and controlled areas within the scope of a legal regulatory procedure. For this purpose, they have to use area dosemeters which are nationally type-approved by the PTB according to the German measurement and verification act. To date, all available type-approved area dosemeters are only tested in continuous radiation fields, and therefore the technical data of the measuring instruments are valid only for continuous radiation. In practice, however, the majority of facilities use pulsed radiation X-rays. Since no other measuring equipment is available, the authorised experts use supposedly unsuitable dosemeters. But is this really so? In the scope of this article, instruments typically used for these measurements were tested to investigate their behaviour in pulsed radiation fields. The approach is similar to that of Friedrich et al.


  • Determination of the dose to persons assisting when X-radiation is used in medicine, dentistry and veterinary medicine

    by O. Hupe, U. Ankerhold

    During medical X-ray examinations of patients, humans as well as animals, voluntarily assisting persons are frequently needed in order to calm down the patient or animal. Typical exposure situations have been identified and measurements were performed in the fields of scattered X-rays. The personal dose equivalent Hp(10) for persons assisting knowingly and willingly in X-ray examinations in dentistry, and human and veterinary medicine was measured. The typical dose values, measured above the protective lead apron, are in the order of a few microsieverts.


  • Dose to persons assisting voluntarily during X-ray examinations of large animals

    by O. Hupe, U. Ankerhold

    Pet owners often assist voluntarily while their pets are being X-rayed during a medical examination. Medical staff members occupationally exposed to radiation are monitored regularly, as they wear personal dosemeters, whereas no dose measurements are carried out on voluntarily assisting persons, as measurements are both cost- and time-intensive. However, the dose limits prescribed in the German radiation protection regulations have to be observed for these volunteers as well. To assist the legislator in deciding whether the German regulation should be changed so that in future the dose of voluntarily assisting persons should also be determined—either by wearing a dosemeter or in another way—investigations with regard to the radiation dose exposure suffered by volunteers were performed within the scope of a research project. The personal dose equivalent Hp(10) for persons assisting knowingly and willingly in X-ray examinations in veterinary medicine was measured for different examination scenarios. Typical exposure situations have been identified and measurements performed in the field of scattered X-rays. The measurements were carried out on animals in veterinary practices and, to verify these measurements, also under laboratory conditions. This paper deals with X-ray examinations of large animals, with the focus especially on horses. The measured personal dose equivalent values of voluntary helpers in equine radiology are in the order of a few microsieverts.


  • A novel method of radiochromic film dosimetry using a color scanner

    by Oliver Hupe, Jens Brunzendorf

    A procedure that allows the improved extraction of the dose information based on the multicolor scanning of the radiochromic film is presented. The basic principle is the determination of the dose values from each color channel of the digital film image in RGB format by applying a nonlinear calibration function. The best estimate of the dose is then a weighted mean of the dose values derived from each color channel. The weighting factors are determined in such a way that the noise in the two‐dimensional dose profile is at the minimum. The calculation of the weighting factors is presented; they are chosen to be proportional to the signal‐to‐noise ratio, , in all three color channels, =red, green, or blue. The data reduction can be fully computerized, including the “cleaning” of the digital image from dust and scratches. It is highly reproducible, which is important for quality assurance, and easy to use. Our novel evaluation procedure combines the good response in the low dose range of the red color with the extended dose range of the blue and green color channels (response up to ), making use of one single, steady evaluation function. Therefore, a smooth evaluation is possible in a wide dose range. For the interpretation of measurements with the radiochromic films the spatial inhomogeneity of the film's response to ionizing radiation is very important. Investigations on both film types, HS and MD55‐2, as well as on the new EBT film have been carried out.


  • Open Access

    Determination of ambient and personal dose equivalent for personnel and cargo security screening

    by O. Hupe, U. Ankerhold

    In the past few years, imaging technology using ionising radiation has been gaining in importance for the screening of goods and persons for security reasons and in order to detect contraband. For radiation protection purposes it is extremely important to know that dose persons are exposed to when passing through a personnel scanner or, as a stowaway, in a cargo scanner, so as to remain within the prescribed dose limits. Within the scope of a research project, measurements were performed on different types of personnel X-ray scanners as well as cargo X-ray scanners, using the transmission and/or the backscattering method. All scanners investigated operate with a high dose rate and use short irradiation time. Owing to this method of scanning reliable values can only be determined for the personal and ambient dose equivalents, Hp(10) and H*(10), by using a specially developed measuring system. The aim of this project was to determine the range of magnitudes of doses for representative personnel and cargo X-ray scanner systems. Depending on the type of scanner, the determined dose values for personnel scanners range from 0.07 μSv to 6 μSv. Measurements and instruments used in this study are described and the dose values obtained are discussed in detail.