FBFalk Birkenfeld

Falk Birkenfeld

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Falk Birkenfeld has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Ralph Lucius

    Institute of Anatomy, Christian-Albrechts University, Kiel, Germany

    7 shared publications
  • Matthias Kern

    Department of Prosthodontics Christian Albrecht University of Kiel University Hospital Schleswig‐Holstein Campus Kiel Kiel Germany

    6 shared publications
  • Stephan Thomas Dmd Becker

    From the *Institute of Anatomy, Christian-Albrechts University Kiel, Otto-Hahn-Platz 8, 24118 Kiel, and †Dental School, Department of Prosthodontics, Propaedeutics and Dental Materials, Christian-Albrechts University Kiel, Arnold-Heller-Str. 16, 24105 Kiel; and ‡Department of Oral and Maxillofacial Surgery, Christian-Albrechts University Kiel, Arnold-Heller-Str. 16, 24105 Kiel, Germany

    3 shared publications
  • Jörg Dmd Wiltfang

    From the *Institute of Anatomy, †Dental School, Department of Prosthodontics, Propaedeutics and Dental Materials, and ‡Department of Oral and Maxillofacial Surgery, Christian-Albrechts University Kiel, Kiel, Germany

    2 shared publications
  • Merlind Erika Becker

    2 shared publications
  • Merlind Erika Dmd Becker

    From the *Institute of Anatomy, †Dental School, Department of Prosthodontics, Propaedeutics and Dental Materials, and ‡Department of Oral and Maxillofacial Surgery, Christian-Albrechts University Kiel, Kiel, Germany

    2 shared publications

Latest Publications

  • Highly porous hydroxyapatite with and without local harvested bone in sinus floor augmentation: a histometric study in pigs

    by Björn Möller, Yahya Acil, Falk Birkenfeld, Eleonore Behrens, Hendrik Terheyden, Jörg Wiltfang

    Objective Sinus floor augmentation with autologous bone is an accepted treatment option in dental implantology. In this study, an entirely synthetic, nano-structured, hydroxyapatite-based bone substitute material (SBSM, NanoBone®; Artoss, Rostock, Germany) was supplemented with a mixture of locally harvested bone to enhance osteogenesis. Methods Bilateral sinus augmentation procedures were performed in eight domestic pigs using the lateral window technique. On the right side (control), 2.6 ml of SBSM was used, and on the left side (test), 2.6 ml of SBSM with additional 15% (390 μl) autologous bone was used. At the time of augmentation, a titanium implant (ITI®) was inserted from a laterocaudal direction. After 3 months, the sites of augmentation were removed and examined in non-decalcified sections by microradiography and fluorescence microscopy of sequentially labelled specimens and histometry. Results On both sides, a significant amount of newly formed bone was observed. However, a statistically significant difference in the bone-implant contact was observed in the control group (median, 28.9%) compared with the test side with the additional autologous bone (median, 40.6%) (P = 0.01). Different bone density was achieved from the coronal to apical surfaces (medians, 54.6%, 9.6%, and 27.5%) compared with the test side (medians, 55.2%, 40.6%, and 44.2%). The median of augmentation height was 8.6 mm on the control side and 11.5 mm on the test side (P = 0.01). Bone apposition was observed in both groups after 15 days. Conclusion The SBSM shows acceptable results in sinus floor augmentation. The additional use of locally harvested autologous bone enhances bone density and osseointegration of the implants.


  • Open Access

    Leakage of fluid around endotracheal tube cuffs: a cadaver study

    by Falk Birkenfeld, Ralph Lucius, Kristian Ewald

    The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülke & Mayr GmbH, Norderstedt, Germany]) was applied for thirty seconds in the mouth. During the trial, leakage of the cuffs was examined. The sealing between the tracheal cuff and tracheal wall was leakage-proof for all tested intracuff pressures and all tested antiseptic rinses. However, approximately 5.6 ml and 1.8 ml leaked into the esophagus and remained as a cuff-puddle, respectively. The sealing between an endotracheal tube cuff with an intracuff pressure of 30 cmH2O and the tracheal wall is leakage-proof during oral care with antiseptic rinsing. An increase of intracuff pressure to 100 cmH2O does not appear to be required.


  • Forces affecting orbital floor reconstruction materials – A cadaver study

    by Falk Birkenfeld, Martin Steiner, Matthias Kern, Jörg Wiltfang, Björn Möller, Ralph Lucius, Stephan Thomas Becker


    • 29 November 2012
      • Vol. 27  (6) , 1382-8

    Increased intraosseous temperature caused by ultrasonic devices during bone surgery and the influences of working pressure and cooling irrigation.

    by Falk Birkenfeld, Merlind Erika Becker, Sönke Harder, Ralph Lucius, Matthias Kern

    The purpose of this study was to investigate the increases in intraosseous temperature generated by a modern ultrasonic device for bone surgery (UDBS) and the influences of working pressure and cooling irrigation on this temperature. Twenty human mandibular bone specimens (20x15x5 to 7 mm) were used; three vertical cuts were performed for a duration of 12 seconds per cut. Each bone specimen was machined with a different combination of working pressure (1.5, 2.0, 3.0, 4.0, or 6.0 N) and cooling irrigation (0, 30, 60, or 90 mL/min), and intraosseous temperatures were measured. Harmful temperature development was defined as an increase of more than 10°C for the 75th percentile and/or a maximum increase of more than 15°C. Cutting performance was also measured. Harmless intraosseous temperature development was identified for working pressures of 1.5 N and 2.0 N with cooling irrigations of 30, 60, and 90 mL/min and for 3.0 N at 90 mL/min. The maximum temperature observed was 72°C (6.0 N with 60 mL/min). The mean cutting performance values were 0.21±0.02 mm/s for 6.0 N, 0.21±0.06 mm/s for 3.0 N, 0.20±0.01 mm/s for 4.0 N, 0.11±0.05 mm/s for 1.5 N, and 0.08±0.03 mm/s for 2.0 N. To prevent tissue damage in dental bone surgery, a minimum coolant amount of 30 mL/min is recommended. The working pressure should be chosen with great care because of its significant influence on intraosseous temperature. Doubling of the working pressure from 1.5 to 3.0 N requires a tripling of the coolant (30 to 90 mL/min) to prevent tissue damage. A working pressure above 3.0 N did not result in improved cutting performance.


  • Maximum Forces Applied to the Orbital Floor After Fractures

    by Falk Dmd Birkenfeld, Martin Dr. Rer. Nat Steiner, Matthias Dmd Kern, Jörg Dmd Witlfang, Björn Dmd Möller, Ralph Lucius, Stephan Thomas Dmd Becker

    The objective of this study was to measure the force on and displacement of completely detached intraorbital tissue from thebony orbit, as a worst-case scenario after orbital trauma, to preserve the maximum load and predict the necessary strength of reconstruction materials. Six fresh-frozen human heads were used, and orbital floor defects in the right and left orbits were created by the direct impact of 3.0 J onto the globe and infraorbital rim. The orbital floor defect sizes and displacements were evaluated after performing a Le Fort I osteotomy. In addition, after the repositioning of the completely detached intraorbital tissue, the forces and displacements were measured. The mean orbital floor defect sizes were 208.3 (SD, 33.4) mm2 for globe impacts and 221.8 (SD, 53.1) mm2 for infraorbital impacts. The mean intraorbital tissue displacement after the impact and before repositioning was 5.6 (SD, 1.0) mm for globe impacts and 2.8 (SD, 0.7) mm for infraorbital impacts. After repositioning, the displacements were 0.8 (SD, 0.5) mm and 1.1 (SD, 0.7) mm, respectively. The measured forces were 0.10519 (SD, 0.00958) N without the incorporation and approximately 0.11128 (SD, 0.003599) N with the incorporation of reconstruction materials. The maximum forces on the completely detached orbital tissue were minimal (∼0.11 N) and suggest the use of collagen membranes as reconstruction materials for orbital floor defects, at least in medium-sized fractures.


  • Forces Charging the Orbital Floor After Orbital Trauma

    by Falk Dmd Birkenfeld, Martin DrRerNat Steiner, Merlind Erika Dmd Becker, Matthias Dmd Kern, Jörg Dmd Wiltfang, Ralph Lucius, Stephan Thomas Dmd Becker

    The objectives of this study were (i) to evaluate different fracture mechanisms for orbital floor fractures and (ii) to measure forces and displacement of intraorbital tissue after orbital traumata to predict the necessity of strength for reconstruction materials. Six fresh frozen human heads were used, and orbital floor defects in the right and left orbit were created by a direct impact of 3.0 J onto the globe and infraorbital rim, respectively. Orbital floor defect sizes and displacement were evaluated after a Le Fort I osteotomy. In addition, after reposition of the intraorbital tissue, forces and displacement were measured. The orbital floor defect sizes were 208.3 (SD, 33.4) mm2 for globe impact and 221.8 (SD, 53.1) mm2 for infraorbital impact. The intraorbital tissue displacement after the impact and before reposition was 5.6 (SD, 1.0) mm for globe impact and 2.8 (SD, 0.7) mm for infraorbital impact. After reposition, the displacement was 0.8 (SD, 0.5) mm and 1.1 (SD, 0.7) mm, respectively. The measured applied forces were 0.061 (SD, 0.014) N for globe impact and 0.066 (SD, 0.022) N for infraorbital impact. Different fracture-inductive mechanisms are not reflected by the pattern of the fracture. The forces needed after reposition are minimal (∼0.07 N), which may explain the success of PDS foils [poly-(p-dioxanone)] and collagen membranes as reconstruction materials.


  • Forces Charging the Orbital Floor After Fractures

    by Falk Dmd Birkenfeld, Martin Dr Rer Nat Steiner, Merlind Erika Dmd Becker, Matthias Dmd Kern, Marc Dmd Menzebach, Jörg Dmd Wiltfang, Ralph Lucius, Stephan Thomas Dmd Becker

    The objective of this study was first to establish a method to measure forces and displacement of the orbital content in defects of the orbital floor in truncated fresh and unfixed heads and second to characterize reconstruction materials with regard to punctuation strength and compression. Orbital floor defects (10 × 20 mm and 15 × 20 mm; 3 mm behind the orbital rim) were prepared after Le Fort I osteotomy. The values of force and displacement were recorded in 6 freshly frozen human heads. In addition, the punctuation strength of 2 reconstruction materials (polydioxanone [PDS] foil and collagen membrane) was evaluated using a Zwick Z010 TN1 universal testing machine. The forces of the orbital content (28.41 [SD, 1.6] g) applied to the defects of 10 × 20 mm and 15 × 20 mm with an intact periorbita were 0.04 (SD, 0.003) N (0.0002 MPa) and 0.07 (SD, 0.02) N (0.0002 MPa), respectively, and with a split periorbita were 0.06 (SD, 0.03) N (0.0003 MPa) and 0.08 (SD, 0.06) N (0.00026 MPa), respectively. The displacement values without reconstruction materials of the 10 × 20-mm and 15 × 20-mm defects were 0.94 (SD, 0.7) mm and 1.2 (SD, 0.5) mm, respectively. The PDS foil could withstand forces of 118.9 (SD, 14.1) N (0.375 MPa), and the collagen membrane could withstand forces of 44.5 (SD, 5.3) N (0.14 MPa). This is the first study to report forces charging the orbital floor. The presented results support the use of PDS foils and collagen membranes as reconstruction materials for orbital floor defects, at least in smaller and medium-sized fractures.


  • Changes in human mandibular bone morphology after heat application

    by Falk Birkenfeld, Merlind Erika Becker, Bodo Kurz, Sönke Harder, Matthias Kern, Ralph Lucius