BIBengt Isaksson

Bengt Isaksson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bengt Isaksson has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Greg Nowak

    Columbia Center for Translational Immunology, Department of Medicine, Columbia University, New York, New York, United States

    2 shared publications
  • Stefan Gilg

    Division of Surgery and Oncology, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden

    2 shared publications
  • Anita Lövgren Sandblom

    1 shared publication
  • Bo-Göran Ericzon

    1 shared publication
  • Carl Jorns

    Division of Transplantation Surgery, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden

    1 shared publication
  • Christina Blixt

    Department of Anaesthesia and Intensive Care, Karolinska University Hospital Huddinge, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Hälsovägen, Stockholm, Sweden

    1 shared publication

Latest Publications

  • 502 FGF19 and Bile Acids in Portal and Systemic Serum

    by Helene Johansson, Lisa-Mari Mörk, Meng Li, Helen Zemack, Anita Lövgren Sandblom, Jonas Höijer, Carl Jorns, Stefan Gilg, Ernesto Sparrelid, Bo-Göran Ericzon, et al.

  • Open Access

    Arterial ischemia in the deportalized liver following associating liver partition and portal vein ligation for staged hepatectomy

    by Srinivas Sanjeevi, Ernesto Sparrelid, Stefan Gilg, Eduard Jonas, Bengt Isaksson

    Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) is a novel 2-stage technique intended to induce rapid growth of the future liver remnant (FLR). Initial reports of a 12% mortality rate have sparked debate regarding the safety of the procedure. A 64 years old male was planned for a right-sided hemi-hepatectomy due to colorectal cancer liver metastases. Intra-operatively it was decided to convert to an ALPPS due to unexpectedly small segments 2-4. Post-operative serum laboratory tests indicated an acute liver failure and radiological imaging showed no sign of arterial blood flow to the right hemi-liver. A computed tomography examination on post-operative day 3 revealed that the FLR had increased from 290 to 690 mL in 3 d (138% growth). In the following days serum values gradually improved and stage 2 was carried out on post-operative day 7. The rest of the hospital stay was uneventful and the patient made a full recovery. ALPPS is a fascinating advancement in liver surgery. Despite severe post-operative complications, in properly selected cases it provides successful outcomes that other modalities of treatment cannot offer.


  • Open Access

    Continuous on-line glucose measurement by microdialysis in a central vein. A pilot study

    by Christina Blixt, Olav Rooyackers, Bengt Isaksson, Jan Wernerman

    Introduction: Tight glucose control in the ICU has been proven difficult with an increased risk for hypoglycaemic episodes. Also the variability of glucose may have an impact on morbidity. An accurate and feasible on-line/continuous measurement is therefore desired. In this study a central vein catheter with a microdialysis membrane in combination with an on-line analyzer for continuous monitoring of circulating glucose and lactate by the central route was tested. Methods: A total of 10 patients scheduled for major upper abdominal surgery were included in this observational prospective study at a university hospital. The patients received an extra central venous catheter with a microdialysis membrane placed in the right jugular vein. Continuous microdialysis measurement proceeded for 20 hours and on-line values were recorded every minute. Reference arterial plasma glucose and blood lactate samples were collected every hour. Results: Mean microdialysis-glucose during measurements was 9.8 ± 2.4mmol/l.No statistical difference in the readings was seen using a single calibration compared to eighth hour calibration (P =0.09; t-test). There was a close agreement between the continuous reading and the reference plasma glucose values with an absolute difference of 0.6+ 0.8mmol, or 6.8+ 9.3% and measurements showed high correlation to plasma readings (r = 0.92). Thelimit of agreement was 23.0%(1.94 mmol/l) compared to arterial plasma values with a line of equality close to zero.However, in a Clarke-Error Grid 93.3% of the values are in the A-area,and the remaining part in the B-area.Mean microdialysis-lactate was 1.3 ± 1.1mmol/l. The measurements showed high correlation to the blood readings (r = 0.93). Conclusion: Continuous on-line microdialysis glucose measurement in a central vein is a potential useful technique for continuous glucose monitoring in critically ill patients, but more improvements and testingare needed.


  • Continuous Assessment of Intrahepatic Metabolism by Microdialysis During and After Portal Triad Clamping

    by Bengt Isaksson, Melroy A. D'SOuza, Ulf Jersenius, Johan Ungerstedt, Lars Lundell, Johan Permert, Mikael Björnstedt, Greg Nowak