A. Widmark
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
A. Widmark has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
E. G. Friberg
Norwegian Radiation Protection Authority, Section for Dosimetry and Medical Applications , PO Box 55, NO-1332 Oesteraas , Norway
1 shared publicationE.M. Sager
1 shared publication- Eva G. Friberg
Norwegian Radiation Protection Authority, P.O. Box 55, Østerås 1332, Norway
1 shared publication G. Einarsson
1 shared publicationH Fosmark
1 shared publicationH. Forsmark
1 shared publication
Latest Publications
- 9 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 147 (1-2) , 223-226
Level of compliance with the radiation protection regulation--a survey among Norwegian hospitals and X-ray institutes
To identify the level of compliance with the new radiation protection regulation among Norwegian health care enterprises (HCEs). Totally, 41 HCEs were authorised to use advanced X-ray equipment for medical purposes during 2005–07. Follow-up inspections with 14 HCEs were carried out during 2007–09. Main topics for the inspections were those requirements identified as most challenging to implement in the authorisation process. Totally, 192 non-conformities with the regulation were revealed during the authorisation process. The inspections revealed that 93 % of the inspected HCEs had non-conformities with the regulation. Most common non-conformities dealt with skills in radiation protection, establishment of local diagnostic reference levels, access to medical physicists and performance of quality control of X-ray equipment. Inspections are an effective tool for implementation of regulation the requirements at the HCEs, thus improving radiation protection awareness.
- 9 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 147 (1-2) , 223-226
Level of compliance with the radiation protection regulation--a survey among Norwegian hospitals and X-ray institutes
To identify the level of compliance with the new radiation protection regulation among Norwegian health care enterprises (HCEs). Totally, 41 HCEs were authorised to use advanced X-ray equipment for medical purposes during 2005–07. Follow-up inspections with 14 HCEs were carried out during 2007–09. Main topics for the inspections were those requirements identified as most challenging to implement in the authorisation process. Totally, 192 non-conformities with the regulation were revealed during the authorisation process. The inspections revealed that 93 % of the inspected HCEs had non-conformities with the regulation. Most common non-conformities dealt with skills in radiation protection, establishment of local diagnostic reference levels, access to medical physicists and performance of quality control of X-ray equipment. Inspections are an effective tool for implementation of regulation the requirements at the HCEs, thus improving radiation protection awareness.
- 5 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 147 (1-2) , 99-101
How 'do's' and 'dont's' can be of significant importance in radiation protection: a case report
The Norwegian Radiation Protection Authority (NRPA) was contacted by a cardiology department because of a suspicious radiation burn on a patient. The patient had undergone two bi-ventricular pacemaker implantations and the lesion was recognised as radiation dermatitis. The NRPA sent sets of thermoluminescense dosemeters to the department to measure the skin dose on eight successive patients undergoing bi-ventricular pacemaker implantations. The average maximum entrance surface dose for the eight patients was 5.3 Gy, ranging from 2.0 to 13.1 Gy. A site audit was performed during a procedure, with the aim to observe the general skills in radiation protection. Based on the findings in the audit, a few very simple ‘Do's’ and ‘Don'ts’ were highlighted in a meeting directly after the audit. After the audit, dose measurements were performed on six new patients showing an average maximum entrance surface dose of 0.4 Gy, ranging from 0.2 to 0.8 Gy. The aim of this work was to illustrate the dose reductions that are possible to achieve with a very few basic advices, especially when the operator has suboptimal competence.
- 5 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 147 (1-2) , 99-101
How 'do's' and 'dont's' can be of significant importance in radiation protection: a case report
The Norwegian Radiation Protection Authority (NRPA) was contacted by a cardiology department because of a suspicious radiation burn on a patient. The patient had undergone two bi-ventricular pacemaker implantations and the lesion was recognised as radiation dermatitis. The NRPA sent sets of thermoluminescense dosemeters to the department to measure the skin dose on eight successive patients undergoing bi-ventricular pacemaker implantations. The average maximum entrance surface dose for the eight patients was 5.3 Gy, ranging from 2.0 to 13.1 Gy. A site audit was performed during a procedure, with the aim to observe the general skills in radiation protection. Based on the findings in the audit, a few very simple ‘Do's’ and ‘Don'ts’ were highlighted in a meeting directly after the audit. After the audit, dose measurements were performed on six new patients showing an average maximum entrance surface dose of 0.4 Gy, ranging from 0.2 to 0.8 Gy. The aim of this work was to illustrate the dose reductions that are possible to achieve with a very few basic advices, especially when the operator has suboptimal competence.
- 1 March 2001
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 94 (1) , 133-135
Guidance Levels in the Nordic Countries: A Preliminary Report for Selected Interventional Procedures
The Nordic radiation protection authorities have already published recommended guidance levels for patient doses for six conventional radiological examinations. Over the past two years a similar protocol has been in progress for three interventional procedures. Measurements have been performed in 22 different hospitals in the Nordic countries on patients in the weight range 40-100 kg. The selected procedures are percutaneous transluminal coronary angioplasty (PTCA), percutaneous transluminal angioplasty (PTA) and endoscopic retrograde cholangio- and pancreatio-graphy (ERCP). A total of 281 PTCA procedures, 304 PTA procedures and 147 ERCP procedures are included in the study. The results from this survey are presented as a first attempt to set guidance levels.
- 1 March 2001
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 94 (1) , 133-135
Guidance Levels in the Nordic Countries: A Preliminary Report for Selected Interventional Procedures
The Nordic radiation protection authorities have already published recommended guidance levels for patient doses for six conventional radiological examinations. Over the past two years a similar protocol has been in progress for three interventional procedures. Measurements have been performed in 22 different hospitals in the Nordic countries on patients in the weight range 40-100 kg. The selected procedures are percutaneous transluminal coronary angioplasty (PTCA), percutaneous transluminal angioplasty (PTA) and endoscopic retrograde cholangio- and pancreatio-graphy (ERCP). A total of 281 PTCA procedures, 304 PTA procedures and 147 ERCP procedures are included in the study. The results from this survey are presented as a first attempt to set guidance levels.
- 30 November 1998
- Vol. 118 (29) , 4543-5
[Radiation hazards in interventional radiology].
- 1 September 1993
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 49 (1-3) , 207-208
A Norwegian Survey on Mammography
- 1 September 1993
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 49 (1-3) , 207-208
A Norwegian Survey on Mammography