Malte Bellmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Malte Bellmann has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Thomas Schmalz
Ottobock SE & Co. KGaA, Clinical Research and Services, Research Biomechanics, 37075 Göttingen, Germany
4 shared publicationsSiegmar Blumentritt
3 shared publicationsEva Ludwigs
2 shared publications- Thomas Maximilian Köhler
Clinical Research and Services, Research Biomechanics, Ottobock SE & Co. KGaA, Göttingen, Germany
1 shared publication
Latest Publications
- Open Access
- 12 December 2018
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 64 (4) , 407-420
Comparative biomechanical evaluation of two technologically different microprocessor-controlled prosthetic knee joints in safety-relevant daily-life situations
Safety-relevant gait situations (walking on stairs and slopes, walking backwards, walking with small steps, simulated perturbations of swing phase extension) were investigated in a motion analysis laboratory with six unilateral transfemoral amputees using two different microprocessor-controlled prosthetic knee joints (Rheo Knee XC, C-Leg). A randomized crossover design was chosen. The study results imply that the performance and safety potential of a microprocessor-controlled knee joint can be associated with the individual control algorithms and the technological concepts that are implemented to generate motion resistances for controlling flexion and extension movements. When walking with small steps, advantages of the “default swing” concept used in the Rheo Knee XC were identified due to a highly reproducible swing phase release. However, when walking backwards, this concept may lead to an uncontrolled knee flexion which partly resulted in falls. When walking down stairs, walking on slopes or while recovering from a stumble after perturbations of the swing phase extension, the C-Leg demonstrated a reliable prosthetic side load-bearing capacity resulting in reduced loading on the residual body. In contrast, the Rheo Knee XC required increased compensatory movements of the remaining locomotor system in order to compensate for reduced load-bearing and safety reserves.
- 12 December 2018
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 64 (4) , 407-420
Open AccessComparative biomechanical evaluation of two technologically different microprocessor-controlled prosthetic knee joints in safety-relevant daily-life situations
Safety-relevant gait situations (walking on stairs and slopes, walking backwards, walking with small steps, simulated perturbations of swing phase extension) were investigated in a motion analysis laboratory with six unilateral transfemoral amputees using two different microprocessor-controlled prosthetic knee joints (Rheo Knee XC, C-Leg). A randomized crossover design was chosen. The study results imply that the performance and safety potential of a microprocessor-controlled knee joint can be associated with the individual control algorithms and the technological concepts that are implemented to generate motion resistances for controlling flexion and extension movements. When walking with small steps, advantages of the “default swing” concept used in the Rheo Knee XC were identified due to a highly reproducible swing phase release. However, when walking backwards, this concept may lead to an uncontrolled knee flexion which partly resulted in falls. When walking down stairs, walking on slopes or while recovering from a stumble after perturbations of the swing phase extension, the C-Leg demonstrated a reliable prosthetic side load-bearing capacity resulting in reduced loading on the residual body. In contrast, the Rheo Knee XC required increased compensatory movements of the remaining locomotor system in order to compensate for reduced load-bearing and safety reserves.
- 1 March 2012
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 93 (3) , 541-549
Immediate Effects of a New Microprocessor-Controlled Prosthetic Knee Joint: A Comparative Biomechanical Evaluation
- 1 March 2012
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 93 (3) , 541-549
Immediate Effects of a New Microprocessor-Controlled Prosthetic Knee Joint: A Comparative Biomechanical Evaluation
- 1 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (6) , 435-44
Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint
Climbing stairs can pose a major challenge for above-knee amputees as a result of compromised motor performance and limitations to prosthetic design. A new, innovative microprocessor-controlled prosthetic knee joint, the Genium, incorporates a function that allows an above-knee amputee to climb stairs step over step. To execute this function, a number of different sensors and complex switching algorithms were integrated into the prosthetic knee joint. The function is intuitive for the user. A biomechanical study was conducted to assess objective gait measurements and calculate joint kinematics and kinetics as subjects ascended stairs. Results demonstrated that climbing stairs step over step is more biomechanically efficient for an amputee using the Genium prosthetic knee than the previously possible conventional method where the extended prosthesis is trailed as the amputee executes one or two steps at a time. There is a natural amount of stress on the residual musculoskeletal system, and it has been shown that the healthy contralateral side supports the movements of the amputated side. The mechanical power that the healthy contralateral knee joint needs to generate during the extension phase is also reduced. Similarly, there is near normal loading of the hip joint on the amputated side.
- 1 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (6) , 435-44
Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint
Climbing stairs can pose a major challenge for above-knee amputees as a result of compromised motor performance and limitations to prosthetic design. A new, innovative microprocessor-controlled prosthetic knee joint, the Genium, incorporates a function that allows an above-knee amputee to climb stairs step over step. To execute this function, a number of different sensors and complex switching algorithms were integrated into the prosthetic knee joint. The function is intuitive for the user. A biomechanical study was conducted to assess objective gait measurements and calculate joint kinematics and kinetics as subjects ascended stairs. Results demonstrated that climbing stairs step over step is more biomechanically efficient for an amputee using the Genium prosthetic knee than the previously possible conventional method where the extended prosthesis is trailed as the amputee executes one or two steps at a time. There is a natural amount of stress on the residual musculoskeletal system, and it has been shown that the healthy contralateral side supports the movements of the amputated side. The mechanical power that the healthy contralateral knee joint needs to generate during the extension phase is also reduced. Similarly, there is near normal loading of the hip joint on the amputated side.
- 1 April 2010
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 91 (4) , 644-652
Comparative Biomechanical Analysis of Current Microprocessor-Controlled Prosthetic Knee Joints
- 1 April 2010
- Published by Elsevier in Archives of Physical Medicine and Rehabilitation
- Vol. 91 (4) , 644-652
Comparative Biomechanical Analysis of Current Microprocessor-Controlled Prosthetic Knee Joints