Jamila S. AlSuwaidi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jamila S. AlSuwaidi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
A.A. Al Blooshi
Dubai Health Authority, Primary Health Care, Radiology Department, United Arab Emirates
1 shared publicationAli Rahanjam
Department of Radiology, Dubai Health Authority, Dubai Hospital, Dubai, United Arab Emirates
1 shared publicationD. Mathew
Dubai Health Authority, Primary Health Care, Radiology Department, United Arab Emirates
1 shared publicationH. Sulaiman
Medical Physics and Radiology Departments, Dubai Health Authority, Dubai Hospital , Dubai , United Arab Emirates
1 shared publicationHashim M. AlAwadhi
Department of Radiology, Dubai Health Authority, Dubai Hospital, Dubai, United Arab Emirates
1 shared publicationJassem S. Ibrahim
Department of Radiology, Dubai Health Authority, Dubai Hospital, Dubai, United Arab Emirates
1 shared publication
Latest Publications
- Open Access
- 12 March 2015
- Published by SAGE Publications in Annals of the ICRP
- Vol. 44 (1_suppl) , 249-258
Patient dose monitoring in Dubai in radiography and interventional procedures
This paper presents ongoing actions in Dubai on patient dose monitoring in digital radiographic examinations, mammography, interventional procedures, and dental radiological procedures. The aim of Dubai Health Authority (DHA) is to move towards the establishment of local diagnostic reference levels. DHA has participated in national and regional projects under the umbrella of the International Atomic Energy Agency. The need for local radiation protection educational programmes and wider patient dosimetry monitoring and recording emerged from this work.
- 12 March 2015
- Published by SAGE Publications in Annals of the ICRP
- Vol. 44 (1_suppl) , 249-258
Open AccessPatient dose monitoring in Dubai in radiography and interventional procedures
This paper presents ongoing actions in Dubai on patient dose monitoring in digital radiographic examinations, mammography, interventional procedures, and dental radiological procedures. The aim of Dubai Health Authority (DHA) is to move towards the establishment of local diagnostic reference levels. DHA has participated in national and regional projects under the umbrella of the International Atomic Energy Agency. The need for local radiation protection educational programmes and wider patient dosimetry monitoring and recording emerged from this work.
- 1 October 2013
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 201 (4) , 858-864
Continuous Monitoring of CT Dose Indexes at Dubai Hospital
OBJECTIVE. Experience of continuous monitoring and control of patient doses in CT in Dubai Hospital over a period of approximately 4 years (January 2008 through August 2011) is presented. MATERIALS AND METHODS. Dose measurements—in particular, weighted and volumetric CT dose index, dose-length product (DLP), and estimated effective dose—were regularly monitored using head (16 cm diameter) and body (32 cm diameter) CT phantoms. Patient radiation dose indexes were manually recorded during 2008 for common CT examinations: head, chest, and abdomen and pelvis scans. In 2009–2011, these CT dose data were recorded within the radiology information system and the PACS. Dose reduction actions were taken while maintaining a watch on image quality. The effects of these factors were monitored through change in average DLP on a monthly basis and third quartile annually. Adapted diagnostic reference levels were used for comparison. RESULTS. The reduction in adult dose indexes in 2010 as compared with 2008 was 52%, 16.4%, and 34.8% for head, chest, and abdomen and pelvis examinations, respectively. For the pediatric group, the reduction was 45.23%, 39.6%, and 43.34% for head, chest, and abdomen and pelvis examinations, respectively. CONCLUSION. Substantial reduction in DLP for common examinations of adults and children is shown through a program of continuous monitoring and action. The results indicate the need to introduce local diagnostic reference levels to substitute for the adapted ones.
- 1 October 2013
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 201 (4) , 858-864
Continuous Monitoring of CT Dose Indexes at Dubai Hospital
OBJECTIVE. Experience of continuous monitoring and control of patient doses in CT in Dubai Hospital over a period of approximately 4 years (January 2008 through August 2011) is presented. MATERIALS AND METHODS. Dose measurements—in particular, weighted and volumetric CT dose index, dose-length product (DLP), and estimated effective dose—were regularly monitored using head (16 cm diameter) and body (32 cm diameter) CT phantoms. Patient radiation dose indexes were manually recorded during 2008 for common CT examinations: head, chest, and abdomen and pelvis scans. In 2009–2011, these CT dose data were recorded within the radiology information system and the PACS. Dose reduction actions were taken while maintaining a watch on image quality. The effects of these factors were monitored through change in average DLP on a monthly basis and third quartile annually. Adapted diagnostic reference levels were used for comparison. RESULTS. The reduction in adult dose indexes in 2010 as compared with 2008 was 52%, 16.4%, and 34.8% for head, chest, and abdomen and pelvis examinations, respectively. For the pediatric group, the reduction was 45.23%, 39.6%, and 43.34% for head, chest, and abdomen and pelvis examinations, respectively. CONCLUSION. Substantial reduction in DLP for common examinations of adults and children is shown through a program of continuous monitoring and action. The results indicate the need to introduce local diagnostic reference levels to substitute for the adapted ones.
- 16 August 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 147 (1-2) , 321-324
Utilisation of PACS to monitor patient CT doses
In the past 5 y, the number of computed tomography (CT) studies has doubled at Dubai Health Authority hospitals. This situation, along with patient's overdoses reported internationally, has prompted action to establish a system to manage patient doses incurred due to medical imaging practices. In this work, the authors aim to homogenise dose reporting to monitor radiation dose levels and facilitate the establishment of local and national dose reference levels. The two hospitals enrolled in this study are equipped with three CT systems (two 4 slices and one 64 slices). Through the Picture Archive and Communication Systems (PACS) tracking system, it is mandatory to fill CT patient doses in radiology information system (RIS). Dose length product (mGy cm) was recorded for 2502 adult and 178 paediatric patients. All patients' dosimetry data were collected from the RIS by Cogonos statistical software. The PACS data were reviewed to exclude incomplete data. Average and range of effective doses for adult and paediatric patients were calculated using an appropriate weighting factor. Individual accumulated effective doses for adult and paediatric patients were calculated for 4s-scanner-1 only. Adult average effective doses for the head (1482 exams) were 1.23±0.58, 2.84±0.83 and 2.98±1.103 mSv, the chest (545 exams) were 5.39±1.63, 21.85±5.63 and 18.19±3.22 mSv and for the abdomen and pelvis (1183 exams) were 10.85±4.26, 25.66±8.83 and 26.46±13.75 mSv for 4s-scanner-1, 4s-scanner-2 and 64 s, respectively. The paediatric average effective dose for the head (127 exams) was 1.77±0.82 mSv, for the chest (22 exams) was 3.3±1.29 mSv and for the abdomen and pelvis (27 exams) was 6.16±2.64 mSv. Results of individual accumulated effective doses for adult and paediatric patients were presented. PACS dose reporting facilitated dosimetry clinical auditing. Effective doses obtained in this work demonstrated that the results of one scanner were within the international dose levels while the other two scanners were higher. Technical actions are recommended to standardise the dose levels.
- 16 August 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 147 (1-2) , 321-324
Utilisation of PACS to monitor patient CT doses
In the past 5 y, the number of computed tomography (CT) studies has doubled at Dubai Health Authority hospitals. This situation, along with patient's overdoses reported internationally, has prompted action to establish a system to manage patient doses incurred due to medical imaging practices. In this work, the authors aim to homogenise dose reporting to monitor radiation dose levels and facilitate the establishment of local and national dose reference levels. The two hospitals enrolled in this study are equipped with three CT systems (two 4 slices and one 64 slices). Through the Picture Archive and Communication Systems (PACS) tracking system, it is mandatory to fill CT patient doses in radiology information system (RIS). Dose length product (mGy cm) was recorded for 2502 adult and 178 paediatric patients. All patients' dosimetry data were collected from the RIS by Cogonos statistical software. The PACS data were reviewed to exclude incomplete data. Average and range of effective doses for adult and paediatric patients were calculated using an appropriate weighting factor. Individual accumulated effective doses for adult and paediatric patients were calculated for 4s-scanner-1 only. Adult average effective doses for the head (1482 exams) were 1.23±0.58, 2.84±0.83 and 2.98±1.103 mSv, the chest (545 exams) were 5.39±1.63, 21.85±5.63 and 18.19±3.22 mSv and for the abdomen and pelvis (1183 exams) were 10.85±4.26, 25.66±8.83 and 26.46±13.75 mSv for 4s-scanner-1, 4s-scanner-2 and 64 s, respectively. The paediatric average effective dose for the head (127 exams) was 1.77±0.82 mSv, for the chest (22 exams) was 3.3±1.29 mSv and for the abdomen and pelvis (27 exams) was 6.16±2.64 mSv. Results of individual accumulated effective doses for adult and paediatric patients were presented. PACS dose reporting facilitated dosimetry clinical auditing. Effective doses obtained in this work demonstrated that the results of one scanner were within the international dose levels while the other two scanners were higher. Technical actions are recommended to standardise the dose levels.