Marilyn J. Goske
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marilyn J. Goske has a total of 207 co-authors. Here are the top co-authors by number of shared publications:
- Donald P. Frush
Department of Radiology, Duke University Medical Center, Durham, USA
7 shared publications Gregory Morrison
American Society of Radiologic Technologists
6 shared publicationsKeith J. Strauss
Cincinnati Children’s Hospital Medical Center
6 shared publications- Kimberly E. Applegate
Department of Radiology (retired), University of Kentucky College of Medicine, 800 Rose Street, Lexington, 40506-9983, UNITED STATES
5 shared publications Michael J. Callahan
5 shared publications- Brian D. Coley
Department of Radiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, USA
4 shared publications
Latest Publications
- 1 January 2015
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (1) , W95-W103
Improving Health Literacy: Use of an Informational Brochure Improves Parents’ Understanding of Their Child's Fluoroscopic Examination
OBJECTIVE. The purpose of this study was to determine parents' knowledge about pediatric fluoroscopic procedures and potential risk from ionizing radiation before and after being given an informational brochure. SUBJECTS AND METHODS. We reviewed responses from 120 randomly selected participants who were parents or guardians of pediatric patients undergoing diagnostic fluoroscopic examinations. A questionnaire assessed participants' knowledge of the procedure, radiation exposure, and whether their child had a prior examination before and after receiving an informational brochure. In a feedback survey, participants rated the brochure. A repeated measures mixed model was used to evaluate the effect of the brochure on the participants' knowledge. RESULTS. Participant demographics were women (79%), English speaking (99%), white (90%), and education higher than 12th grade (76%). The median age of patients undergoing the fluoroscopic examination was 4 years. Participant knowledge increased (p < 0.0001) between pre- and postbrochure (least-squares means) for those without a previous examination from 38.3 to 63.4 (total test score) and from 46.3 to 61.8 for those with a prior examination. The proportion of correct answers was higher (p < 0.0001) postbrochure compared with prebrochure in areas of examination name (99% vs 93%), procedure details (97% vs 87%); use of radiation (100% vs 68%), and radiation dose comparison (79% vs 25%). Overall, 99% (119/120) rated the brochure "good" or "great" (p < 0.0001). CONCLUSION. An informational brochure given to participants before their child's fluoroscopic procedure improved their knowledge of the examination and radiation exposure. No participants refused their child's examination.
- 1 January 2015
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (1) , W95-W103
Improving Health Literacy: Use of an Informational Brochure Improves Parents’ Understanding of Their Child's Fluoroscopic Examination
OBJECTIVE. The purpose of this study was to determine parents' knowledge about pediatric fluoroscopic procedures and potential risk from ionizing radiation before and after being given an informational brochure. SUBJECTS AND METHODS. We reviewed responses from 120 randomly selected participants who were parents or guardians of pediatric patients undergoing diagnostic fluoroscopic examinations. A questionnaire assessed participants' knowledge of the procedure, radiation exposure, and whether their child had a prior examination before and after receiving an informational brochure. In a feedback survey, participants rated the brochure. A repeated measures mixed model was used to evaluate the effect of the brochure on the participants' knowledge. RESULTS. Participant demographics were women (79%), English speaking (99%), white (90%), and education higher than 12th grade (76%). The median age of patients undergoing the fluoroscopic examination was 4 years. Participant knowledge increased (p < 0.0001) between pre- and postbrochure (least-squares means) for those without a previous examination from 38.3 to 63.4 (total test score) and from 46.3 to 61.8 for those with a prior examination. The proportion of correct answers was higher (p < 0.0001) postbrochure compared with prebrochure in areas of examination name (99% vs 93%), procedure details (97% vs 87%); use of radiation (100% vs 68%), and radiation dose comparison (79% vs 25%). Overall, 99% (119/120) rated the brochure "good" or "great" (p < 0.0001). CONCLUSION. An informational brochure given to participants before their child's fluoroscopic procedure improved their knowledge of the examination and radiation exposure. No participants refused their child's examination.
- 11 October 2014
- Published by Springer Nature in Pediatric Radiology
- Vol. 44 (S3) , 403
The Image Gently ALARA CT summit on new CT technologies for children
- 11 October 2014
- Published by Springer Nature in Pediatric Radiology
- Vol. 44 (S3) , 403
The Image Gently ALARA CT summit on new CT technologies for children
- 11 October 2014
- Published by Springer Nature in Pediatric Radiology
- Vol. 44 (S3) , 506-510
Diagnostic reference ranges and the American College of Radiology Dose Index Registry: the pediatric experience
CT scans are powerful tools used in the care of pediatric patients daily. Yet the increased use of CT warrants careful monitoring. This article defines diagnostic reference levels and how they can be used to guide practice. Once a facility has adapted its techniques and protocols to fall within diagnostic reference levels or target values, the facility can expand its quality-improvement efforts to include a new concept, diagnostic reference ranges (DRRs). DRRs take into account the subjective image quality of the examination and provide a minimum estimated patient dose, below which accurate interpretation of an image might be difficult, and an upper estimated dose, above which the patient dose may be higher than necessary. This paper also describes how the American College of Radiology Dose Index Registry can be used by a facility as a continuous quality improvement tool to monitor and manage appropriate patient dose.
- 11 October 2014
- Published by Springer Nature in Pediatric Radiology
- Vol. 44 (S3) , 506-510
Diagnostic reference ranges and the American College of Radiology Dose Index Registry: the pediatric experience
CT scans are powerful tools used in the care of pediatric patients daily. Yet the increased use of CT warrants careful monitoring. This article defines diagnostic reference levels and how they can be used to guide practice. Once a facility has adapted its techniques and protocols to fall within diagnostic reference levels or target values, the facility can expand its quality-improvement efforts to include a new concept, diagnostic reference ranges (DRRs). DRRs take into account the subjective image quality of the examination and provide a minimum estimated patient dose, below which accurate interpretation of an image might be difficult, and an upper estimated dose, above which the patient dose may be higher than necessary. This paper also describes how the American College of Radiology Dose Index Registry can be used by a facility as a continuous quality improvement tool to monitor and manage appropriate patient dose.
- 1 March 2014
- Vol. 28 (3) , 232-8, 243
Curbing potential radiation-induced cancer risks in oncologic imaging: perspectives from the 'image gently' and 'image wisely' campaigns.
Medical imaging that uses ionizing radiation, such as CT, radiography, nuclear medicine, and fluoroscopy, is a cornerstone of the care of oncology patients and provides great benefit. Ionizing radiation at high doses is a known carcinogen.The exact degree of the risk of carcinogenesis from the lower doses of ionizing radiation used in medical imaging is less clear. The purpose of this review is to provide the oncology community with knowledge about the doses used in medical imaging, radiation-induced cancer risks from imaging, considerations to keep in mind when balancing imaging benefits and risks in pediatric and adult oncologic settings, dose reduction strategies, and the "Image Gently" and "Image Wisely" campaigns; the latter campaigns facilitate the translation of existing evidence into best practices for providers and patients.
- 1 March 2014
- Vol. 28 (3) , 232-8, 243
Curbing potential radiation-induced cancer risks in oncologic imaging: perspectives from the 'image gently' and 'image wisely' campaigns.
Medical imaging that uses ionizing radiation, such as CT, radiography, nuclear medicine, and fluoroscopy, is a cornerstone of the care of oncology patients and provides great benefit. Ionizing radiation at high doses is a known carcinogen.The exact degree of the risk of carcinogenesis from the lower doses of ionizing radiation used in medical imaging is less clear. The purpose of this review is to provide the oncology community with knowledge about the doses used in medical imaging, radiation-induced cancer risks from imaging, considerations to keep in mind when balancing imaging benefits and risks in pediatric and adult oncologic settings, dose reduction strategies, and the "Image Gently" and "Image Wisely" campaigns; the latter campaigns facilitate the translation of existing evidence into best practices for providers and patients.
- 1 February 2014
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 87 (1034) , 20130517
Doctor, is a CT scan safe for my child?
- 1 February 2014
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 87 (1034) , 20130517
Doctor, is a CT scan safe for my child?
- 1 July 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 268 (1) , 208-218
Diagnostic Reference Ranges for Pediatric Abdominal CT
To develop diagnostic reference ranges (DRRs) and a method for an individual practice to calculate site-specific reference doses for computed tomographic (CT) scans of the abdomen or abdomen and pelvis in children on the basis of body width (BW). This HIPAA-compliant multicenter retrospective study was approved by institutional review boards of participating institutions; informed consent was waived. In 939 pediatric patients, CT doses were reviewed in 499 (53%) male and 440 (47%) female patients (mean age, 10 years). Doses were from 954 scans obtained from September 1 to December 1, 2009, through Quality Improvement Registry for CT Scans in Children within the National Radiology Data Registry, American College of Radiology. Size-specific dose estimate (SSDE), a dose estimate based on BW, CT dose index, dose-length product, and effective dose were analyzed. BW measurement was obtained with electronic calipers from the axial image at the splenic vein level after completion of the CT scan. An adult-sized patient was defined as a patient with BW of 34 cm. An appropriate dose range for each DRR was developed by reviewing image quality on a subset of CT scans through comparison with a five-point visual reference scale with increments of added simulated quantum mottle and by determining DRR to establish lower and upper bounds for each range. For 954 scans, DRRs (SSDEs) were 5.8-12.0, 7.3-12.2, 7.6-13.4, 9.8-16.4, and 13.1-19.0 mGy for BWs less than 15, 15-19, 20-24, 25-29, and 30 cm or greater, respectively. The fractions of adult doses, adult SSDEs, used within the consortium for patients with BWs of 10, 14, 18, 22, 26, and 30 cm were 0.4, 0.5, 0.6, 0.7, 0.8, and 0.9, respectively. The concept of DRRs addresses the balance between the patient's risk (radiation dose) and benefit (diagnostic image quality). Calculation of reference doses as a function of BW for an individual practice provides a tool to help develop site-specific CT protocols that help manage pediatric patient radiation doses.
- 1 July 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 268 (1) , 208-218
Diagnostic Reference Ranges for Pediatric Abdominal CT
To develop diagnostic reference ranges (DRRs) and a method for an individual practice to calculate site-specific reference doses for computed tomographic (CT) scans of the abdomen or abdomen and pelvis in children on the basis of body width (BW). This HIPAA-compliant multicenter retrospective study was approved by institutional review boards of participating institutions; informed consent was waived. In 939 pediatric patients, CT doses were reviewed in 499 (53%) male and 440 (47%) female patients (mean age, 10 years). Doses were from 954 scans obtained from September 1 to December 1, 2009, through Quality Improvement Registry for CT Scans in Children within the National Radiology Data Registry, American College of Radiology. Size-specific dose estimate (SSDE), a dose estimate based on BW, CT dose index, dose-length product, and effective dose were analyzed. BW measurement was obtained with electronic calipers from the axial image at the splenic vein level after completion of the CT scan. An adult-sized patient was defined as a patient with BW of 34 cm. An appropriate dose range for each DRR was developed by reviewing image quality on a subset of CT scans through comparison with a five-point visual reference scale with increments of added simulated quantum mottle and by determining DRR to establish lower and upper bounds for each range. For 954 scans, DRRs (SSDEs) were 5.8-12.0, 7.3-12.2, 7.6-13.4, 9.8-16.4, and 13.1-19.0 mGy for BWs less than 15, 15-19, 20-24, 25-29, and 30 cm or greater, respectively. The fractions of adult doses, adult SSDEs, used within the consortium for patients with BWs of 10, 14, 18, 22, 26, and 30 cm were 0.4, 0.5, 0.6, 0.7, 0.8, and 0.9, respectively. The concept of DRRs addresses the balance between the patient's risk (radiation dose) and benefit (diagnostic image quality). Calculation of reference doses as a function of BW for an individual practice provides a tool to help develop site-specific CT protocols that help manage pediatric patient radiation doses.
- 19 September 2012
- Vol. 84 (1) , 93-9
Image gently: using exposure indicators to improve pediatric digital radiography.
- 19 September 2012
- Vol. 84 (1) , 93-9
Image gently: using exposure indicators to improve pediatric digital radiography.
- 1 May 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 198 (5) , 992-995
Large-Scale Quality Improvement for Radiation Protection of Children Worldwide: Lessons From the Past Applied to the Present
OBJECTIVE. The objective of this article is to highlight strategies that can be used to implement changes locally for improved safety of pediatric patients. Specific examples of international organizations engaged with quality improvement are discussed. CONCLUSION. Large-scale quality improvement to promote radiation protection for children is being aggressively pursued by numerous international organizations. These international agencies use quality improvement methods on a global scale to optimize medical imaging for all diagnostic imaging modalities that use ionizing radiation with the intent of lowering radiation dose to children. This work, although vast in scope, requires highly focused project goals with access to scientific expertise. In addition, these coordinated efforts must provide education, collegial support, and resources (both financial and technical) that enable radiology professionals to implement change locally for improved safety of pediatric patients.
- 1 May 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 198 (5) , 992-995
Large-Scale Quality Improvement for Radiation Protection of Children Worldwide: Lessons From the Past Applied to the Present
OBJECTIVE. The objective of this article is to highlight strategies that can be used to implement changes locally for improved safety of pediatric patients. Specific examples of international organizations engaged with quality improvement are discussed. CONCLUSION. Large-scale quality improvement to promote radiation protection for children is being aggressively pursued by numerous international organizations. These international agencies use quality improvement methods on a global scale to optimize medical imaging for all diagnostic imaging modalities that use ionizing radiation with the intent of lowering radiation dose to children. This work, although vast in scope, requires highly focused project goals with access to scientific expertise. In addition, these coordinated efforts must provide education, collegial support, and resources (both financial and technical) that enable radiology professionals to implement change locally for improved safety of pediatric patients.
- 1 January 2012
- Published by Springer Nature
- p. 509-535
The Image Gently Campaign: Championing Radiation Protection for Children Through Awareness, Educational Resources and Advocacy
- 1 January 2012
- Published by Springer Nature
- p. 509-535
The Image Gently Campaign: Championing Radiation Protection for Children Through Awareness, Educational Resources and Advocacy
- 17 August 2011
- Published by Springer Nature in Pediatric Radiology
- Vol. 41 (S2) , 461-466
Image Gently: progress and challenges in CT education and advocacy
Significant progress has been made in radiation protection for children during the last 10 years. This includes increased awareness of the need for radiation protection for pediatric patients with international partnerships through the Alliance for Radiation Safety in Pediatric Imaging. This paper identifies five areas of significant progress in radiation safety for children: the growth of the Alliance; the development of an adult radiation protection campaign Image Wisely™; increased collaboration with government agencies, societies and the vendor community; the development of national guidelines in pediatric nuclear medicine, and the development of a size-based patient dose correction factor by the American Association of Physicists in Medicine, Task Group 204. However, many challenges remain. These include the need for continued education and change of practice at adult-focused hospitals where many pediatric CT exams are performed; the need for increased emphasis on appropriateness of pediatric imaging and outcomes research to validate the performance of CT studies, and the advancement of the work of the first pediatric national dose registry to determine the “state of the practice” with the final goal of establishing ranges of optimal CT technique for specific scan indications when imaging children with CT.
- 17 August 2011
- Published by Springer Nature in Pediatric Radiology
- Vol. 41 (S2) , 461-466
Image Gently: progress and challenges in CT education and advocacy
Significant progress has been made in radiation protection for children during the last 10 years. This includes increased awareness of the need for radiation protection for pediatric patients with international partnerships through the Alliance for Radiation Safety in Pediatric Imaging. This paper identifies five areas of significant progress in radiation safety for children: the growth of the Alliance; the development of an adult radiation protection campaign Image Wisely™; increased collaboration with government agencies, societies and the vendor community; the development of national guidelines in pediatric nuclear medicine, and the development of a size-based patient dose correction factor by the American Association of Physicists in Medicine, Task Group 204. However, many challenges remain. These include the need for continued education and change of practice at adult-focused hospitals where many pediatric CT exams are performed; the need for increased emphasis on appropriateness of pediatric imaging and outcomes research to validate the performance of CT studies, and the advancement of the work of the first pediatric national dose registry to determine the “state of the practice” with the final goal of establishing ranges of optimal CT technique for specific scan indications when imaging children with CT.