Angelo Polito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Angelo Polito has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Paola Cogo
Department of Medicine, University Hospital S. Maria Della Misericordia, University of Udine, Udine, Italy
4 shared publications - Zaccaria Ricci
Pediatric Intensive Care Unit, Meyer Children’S Hospital, IRCCS, Florence, Italy
3 shared publications Cindy S. Barrett
From the *Cardiac Intensive Care Unit, Bambino Gesù Pediatric Hospital, Rome, Italy; †Cardiac Intensive Care Unit, Denver Children’s Hospital, Denver, Colorado; ‡Extracorporeal Life Support Organization (ELSO), University of Michigan, Ann Arbor, Michigan; and §Cardiac Intensive Care Unit, Boston Children’s Hospital, Boston, Massachusetts
2 shared publicationsPeter T. Rycus
From the *Cardiac Intensive Care Unit, Bambino Gesù Pediatric Hospital, Rome, Italy; †Cardiac Intensive Care Unit, Denver Children’s Hospital, Denver, Colorado; ‡Extracorporeal Life Support Organization (ELSO), University of Michigan, Ann Arbor, Michigan; and §Cardiac Intensive Care Unit, Boston Children’s Hospital, Boston, Massachusetts
2 shared publicationsRavi R. Thiagarajan
From the *Cardiac Intensive Care Unit, Bambino Gesù Pediatric Hospital, Rome, Italy; †Cardiac Intensive Care Unit, Denver Children’s Hospital, Denver, Colorado; ‡Extracorporeal Life Support Organization (ELSO), University of Michigan, Ann Arbor, Michigan; and §Cardiac Intensive Care Unit, Boston Children’s Hospital, Boston, Massachusetts
2 shared publicationsRoberta Netto
Attending Physician, Department of Cardiology and Cardiac Surgery, Cardiac Intensive Care Unit, Bambino Gesù Pediatric Hospital, IRCCS, Rome, Italy
2 shared publications
Latest Publications
- 1 January 2015
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 61 (1) , 43-48
Neurologic Injury in Neonates with Congenital Heart Disease During Extracorporeal Membrane Oxygenation
The aim of this article is to describe the epidemiology and factors associated with acute neurologic injury in neonates with congenital heart disease (CHD) undergoing extracorporeal membrane oxygenation (ECMO). It is a retrospective cohort study. Multi-institutional data for purposes of this study were obtained from the extracorporeal life support organization registry Neonates with CHD supported with ECMO during 2005–2010. Of 1,898 neonates with CHD supported with ECMO, 273 (14%) had neurologic injury. Birth weight less than 3 kg (odds ratio [OR]: 1.5; 95% confidence intervals [CI]: 1.1–1.9), pre-ECMO blood pH ≤ 7.15 (OR: 1.5, 95% CI: 1.1–2.1) need for cardiopulmonary resuscitation before ECMO (OR: 1.7, 95% CI: 1.5–2.0) increased neurologic injury. In-hospital mortality was higher in patients with neurologic injury compared with those without (73% vs. 53%; p < 0.001). Neonates with CHD undergoing ECMO are highly vulnerable to acute neurologic injury regardless of cardiac lesion-specific physiology or the occurrence of cardiac surgery. The incidence of neurologic injuries in this population is higher in sicker patients. Severity of illness should therefore become the main target for improvement. Timely deployment of ECMO may therefore influence the development of ECMO complications.
- 1 January 2015
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 61 (1) , 43-48
Neurologic Injury in Neonates with Congenital Heart Disease During Extracorporeal Membrane Oxygenation
The aim of this article is to describe the epidemiology and factors associated with acute neurologic injury in neonates with congenital heart disease (CHD) undergoing extracorporeal membrane oxygenation (ECMO). It is a retrospective cohort study. Multi-institutional data for purposes of this study were obtained from the extracorporeal life support organization registry Neonates with CHD supported with ECMO during 2005–2010. Of 1,898 neonates with CHD supported with ECMO, 273 (14%) had neurologic injury. Birth weight less than 3 kg (odds ratio [OR]: 1.5; 95% confidence intervals [CI]: 1.1–1.9), pre-ECMO blood pH ≤ 7.15 (OR: 1.5, 95% CI: 1.1–2.1) need for cardiopulmonary resuscitation before ECMO (OR: 1.7, 95% CI: 1.5–2.0) increased neurologic injury. In-hospital mortality was higher in patients with neurologic injury compared with those without (73% vs. 53%; p < 0.001). Neonates with CHD undergoing ECMO are highly vulnerable to acute neurologic injury regardless of cardiac lesion-specific physiology or the occurrence of cardiac surgery. The incidence of neurologic injuries in this population is higher in sicker patients. Severity of illness should therefore become the main target for improvement. Timely deployment of ECMO may therefore influence the development of ECMO complications.
- 8 June 2013
- Published by Springer Nature in Intensive Care Medicine
- Vol. 39 (9) , 1594-1601
Neurologic complications in neonates supported with extracorporeal membrane oxygenation. An analysis of ELSO registry data
Background Neurologic complications in neonates supported with extracorporeal membrane oxygenation (ECMO) are common and diminish their quality of life and survival. An understanding of factors associated with neurologic complications in neonatal ECMO is lacking. The goals of this study were to describe the epidemiology and factors associated with neurologic complications in neonatal ECMO. Patients and methods Retrospective cohort study of neonates (age ≤30 days) supported with ECMO using data reported to the Extracorporeal Life Support Organization during 2005–2010. Results Of 7,190 neonates supported with ECMO, 1,412 (20 %) had neurologic complications. Birth weight p < 0.001). Conclusions Neurologic complications are common in neonatal ECMO and are associated with increased mortality. Patient factors, pre-ECMO severity of illness, and use of veno-arterial ECMO are associated with increased neurologic complications. Patient selection, early ECMO deployment, and refining ECMO management strategies for vulnerable populations could be targeted as areas for improvement in neonatal ECMO.
- 8 June 2013
- Published by Springer Nature in Intensive Care Medicine
- Vol. 39 (9) , 1594-1601
Neurologic complications in neonates supported with extracorporeal membrane oxygenation. An analysis of ELSO registry data
Background Neurologic complications in neonates supported with extracorporeal membrane oxygenation (ECMO) are common and diminish their quality of life and survival. An understanding of factors associated with neurologic complications in neonatal ECMO is lacking. The goals of this study were to describe the epidemiology and factors associated with neurologic complications in neonatal ECMO. Patients and methods Retrospective cohort study of neonates (age ≤30 days) supported with ECMO using data reported to the Extracorporeal Life Support Organization during 2005–2010. Results Of 7,190 neonates supported with ECMO, 1,412 (20 %) had neurologic complications. Birth weight p < 0.001). Conclusions Neurologic complications are common in neonatal ECMO and are associated with increased mortality. Patient factors, pre-ECMO severity of illness, and use of veno-arterial ECMO are associated with increased neurologic complications. Patient selection, early ECMO deployment, and refining ECMO management strategies for vulnerable populations could be targeted as areas for improvement in neonatal ECMO.
- 5 April 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (10) , 851-856
Neurological Complications During Pulsatile Ventricular Assistance With the Berlin Heart EXCOR in Children: Incidence and Risk Factors
The aim of this study is to describe the incidence of brain injury (BI) in children with end‐stage cardiac failure who were supported with the Berlin Heart EXCOR ventricular assist device (VAD) as a bridge to heart transplantation. Between January 2002 and January 2012, all patients n = 20) and congenital heart disease (n = 5). Eleven patients received atrial cannulation. Nine patients underwent biventricular assist device support. Seven patients underwent extracorporeal membrane oxygenation before the implantation of the EXCOR VAD. Median duration of VAD support was 51 days (range 2–167). Nine patients had evidence of acute BI including intracranial hemorrhage (n = 5) and cerebral ischemia (n = 4). Freedom from BI at 30, 60, and 90 days from VAD implantation was 80.7, 69.9, and 43.3%, respectively. Weight <10 kg at implantation was significantly associated with BI. BI is a frequent complication among children supported with EXCOR VAD and is associated with lower weight at implantation. However, our data do not support the association between size and BI. Future prospective multicenter studies are warranted to further help understand the etiology and the impact of BI and to improve functional outcomes for children undergoing EXCOR VAD mechanical support.
- 5 April 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (10) , 851-856
Neurological Complications During Pulsatile Ventricular Assistance With the Berlin Heart EXCOR in Children: Incidence and Risk Factors
The aim of this study is to describe the incidence of brain injury (BI) in children with end‐stage cardiac failure who were supported with the Berlin Heart EXCOR ventricular assist device (VAD) as a bridge to heart transplantation. Between January 2002 and January 2012, all patients n = 20) and congenital heart disease (n = 5). Eleven patients received atrial cannulation. Nine patients underwent biventricular assist device support. Seven patients underwent extracorporeal membrane oxygenation before the implantation of the EXCOR VAD. Median duration of VAD support was 51 days (range 2–167). Nine patients had evidence of acute BI including intracranial hemorrhage (n = 5) and cerebral ischemia (n = 4). Freedom from BI at 30, 60, and 90 days from VAD implantation was 80.7, 69.9, and 43.3%, respectively. Weight <10 kg at implantation was significantly associated with BI. BI is a frequent complication among children supported with EXCOR VAD and is associated with lower weight at implantation. However, our data do not support the association between size and BI. Future prospective multicenter studies are warranted to further help understand the etiology and the impact of BI and to improve functional outcomes for children undergoing EXCOR VAD mechanical support.
- Open Access
- 28 December 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (6) , 470-2
Vasopressin and terlipressin in adult vasodilatory shock
- 28 December 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (6) , 470-2
Open AccessVasopressin and terlipressin in adult vasodilatory shock
- 9 November 2011
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 22 (1) , 1-7
Balloon atrial septostomy and pre-operative brain injury in neonates with transposition of the great arteries: a systematic review and a meta-analysis
Objective: To perform a systematic review and a meta-analysis of the effects of balloon atrial septostomy on peri-operative brain injury in neonates with transposition of the great arteries.Data source: We conduct a systematic review of the literature to identify all observational studies that included neonates born with transposition of the great arteries who had peri-operative evidence of brain injury.Study selection and data extraction: The search strategy produced three prospective and two retrospective cohort studies investigating the association between balloon atrial septostomy and brain injury totalling 10,108 patients. In two studies, the outcome was represented by the presence of a coded diagnosis of a clinically evident stroke at discharge, whereas in three studies the outcome was represented by the finding of pre-operative brain injury identified by magnetic resonance scans.Data synthesis: The overall brain injury rate for neonates who underwent balloon atrial septostomy versus control patients was 60 of 2273 (2.6%) versus 45 of 7835 (0.5%; pooled odds ratio, 1.90; 95% confidence intervals, 0.93–3.89; p = 0.08). A subgroup analysis of the three studies that used pre-operative brain injury as the primary outcome found no significant association between balloon atrial septostomy and brain injury (pooled odds ratio, 2.70; 95% confidence intervals, 0.64–11.33; p = 0.17). Balloon atrial septostomy frequency was 22.4% (2273 of 10,108), with reported rates ranging from 20% to 75%.Conclusion: Our analysis shows that balloon atrial septostomy is not associated with increased odds for peri-operative brain injury. Balloon atrial septostomy should still be used for those patients with significant hypoxaemia, haemodynamic instability, or both.
- 9 November 2011
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 22 (1) , 1-7
Balloon atrial septostomy and pre-operative brain injury in neonates with transposition of the great arteries: a systematic review and a meta-analysis
Objective: To perform a systematic review and a meta-analysis of the effects of balloon atrial septostomy on peri-operative brain injury in neonates with transposition of the great arteries.Data source: We conduct a systematic review of the literature to identify all observational studies that included neonates born with transposition of the great arteries who had peri-operative evidence of brain injury.Study selection and data extraction: The search strategy produced three prospective and two retrospective cohort studies investigating the association between balloon atrial septostomy and brain injury totalling 10,108 patients. In two studies, the outcome was represented by the presence of a coded diagnosis of a clinically evident stroke at discharge, whereas in three studies the outcome was represented by the finding of pre-operative brain injury identified by magnetic resonance scans.Data synthesis: The overall brain injury rate for neonates who underwent balloon atrial septostomy versus control patients was 60 of 2273 (2.6%) versus 45 of 7835 (0.5%; pooled odds ratio, 1.90; 95% confidence intervals, 0.93–3.89; p = 0.08). A subgroup analysis of the three studies that used pre-operative brain injury as the primary outcome found no significant association between balloon atrial septostomy and brain injury (pooled odds ratio, 2.70; 95% confidence intervals, 0.64–11.33; p = 0.17). Balloon atrial septostomy frequency was 22.4% (2273 of 10,108), with reported rates ranging from 20% to 75%.Conclusion: Our analysis shows that balloon atrial septostomy is not associated with increased odds for peri-operative brain injury. Balloon atrial septostomy should still be used for those patients with significant hypoxaemia, haemodynamic instability, or both.