Zhigang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhigang Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Chengwu Zhang
Energy Research Institute of Shandong Academy of Sciences
4 shared publicationsNing Guan
Energy Research Institute of Shandong Academy of Sciences, Jinan, China
4 shared publicationsCheng-Wu Zhang
Shandong Academy of Sciences
2 shared publicationsGuilin Jiang
Energy Research Institute of Shandong Academy of Sciences
2 shared publicationsGuan Ning
Energy Research Institute of Shandong Academy of Sciences , Jinan, China
1 shared publicationHongxia Zhao
School of Energy and Power Engineering , Shandong University , Jinan , China
1 shared publication
Latest Publications
- 17 October 2013
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 50 (2) , 275-284
Natural convection heat transfer on surfaces of copper micro-wires
- 17 October 2013
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 50 (2) , 275-284
Natural convection heat transfer on surfaces of copper micro-wires
- 15 February 2013
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 49 (5) , 733-744
Flow resistance and heat transfer characteristics in micro-cylinders-group
- 15 February 2013
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 49 (5) , 733-744
Flow resistance and heat transfer characteristics in micro-cylinders-group
- 1 July 2012
- Published by Taylor & Francis in Nanoscale and Microscale Thermophysical Engineering
- Vol. 16 (3) , 165-180
Forced Convective Heat Transfer Characteristics in Micro/Minicylinders Group at Low Reynolds Number
As an effective method for heat transfer enhancement, mini- or microscale pin fin arrays with different arrangements have been employed and studied in heat exchangers for next-generation cooling technology. A forced convective heat transfer characteristic of deionized water flowing through in-line and staggered array micro/minicylinders group plates of microcylinders was experimentally studied. Using an electricity heater, the flow rate and temperature difference between the inlet and outlet of micro/minicylinders group were measured and the Nusselt numbers were obtained over low Reynolds numbers ranging from 8 to 100. The results indicate that the experimental Nu number was less than that of the classical correlation. The height of the cylinder plays a role due to the appearance of the sluggish regions in micro/minicylinders at low Reynolds number and the combined actions of some dimensional effects, such as the conjugate heat transfer effect, the end wall effect, and the thermophysical properties with temperature variation effect, etc. The distance between the outermost cylinders and the wall of the micro/minicylinders group plate affects the experimental Nu number of a staggered array more apparently than that of an in-line array when Re > 20, which resulted from a stronger brim effect according to the present experimental results.
- 1 July 2012
- Published by Taylor & Francis in Nanoscale and Microscale Thermophysical Engineering
- Vol. 16 (3) , 165-180
Forced Convective Heat Transfer Characteristics in Micro/Minicylinders Group at Low Reynolds Number
As an effective method for heat transfer enhancement, mini- or microscale pin fin arrays with different arrangements have been employed and studied in heat exchangers for next-generation cooling technology. A forced convective heat transfer characteristic of deionized water flowing through in-line and staggered array micro/minicylinders group plates of microcylinders was experimentally studied. Using an electricity heater, the flow rate and temperature difference between the inlet and outlet of micro/minicylinders group were measured and the Nusselt numbers were obtained over low Reynolds numbers ranging from 8 to 100. The results indicate that the experimental Nu number was less than that of the classical correlation. The height of the cylinder plays a role due to the appearance of the sluggish regions in micro/minicylinders at low Reynolds number and the combined actions of some dimensional effects, such as the conjugate heat transfer effect, the end wall effect, and the thermophysical properties with temperature variation effect, etc. The distance between the outermost cylinders and the wall of the micro/minicylinders group plate affects the experimental Nu number of a staggered array more apparently than that of an in-line array when Re > 20, which resulted from a stronger brim effect according to the present experimental results.
- 13 January 2012
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 48 (7) , 1141-1153
Numerical investigation on heat transfer of liquid flow at low Reynolds number in micro-cylinder-groups
- 13 January 2012
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 48 (7) , 1141-1153
Numerical investigation on heat transfer of liquid flow at low Reynolds number in micro-cylinder-groups
- 15 January 2011
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 47 (6) , 691-702
Investigations on viscous dissipation effect of liquid flow in microtubes
- 15 January 2011
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 47 (6) , 691-702
Investigations on viscous dissipation effect of liquid flow in microtubes
- 7 August 2008
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 45 (3) , 297-304
Experimental study on influence of microscale effects on liquid flow characteristic in microtubes
- 7 August 2008
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 45 (3) , 297-304
Experimental study on influence of microscale effects on liquid flow characteristic in microtubes
- 11 December 2007
- Published by Taylor & Francis in Nanoscale and Microscale Thermophysical Engineering
- Vol. 11 (3-4) , 333-349
An Experimental Investigation of Single-Phase Heat Transfer in 0.045mm to 0.141mm Microtubes
Deioned water, used as the working fluid, flowed through the quartz glass microtubes with inner diameters of 45, 92, and 141 μm, respectively, which was heated by a directly electrifying brass wire coiled evenly up around them. As the Reynolds number varied in the range from 100 up to 3000 in the experiments the corresponding Nussult number was obtained. The experimental results showed that the experimental Nussult numbers were less than predictions of the classical laminar correlations at a lower Reynolds number, which resulted from the effects of the variation of the thermophysical properties with temperature and nonlinear temperature variation of the working fluid along the wall. With the increase of the Reynolds number, the experimental data sharply increased and they were higher than the predictions by the classical transitional correlations due to the conjugate effects of the thinner conductive liquid layer, the entrance length, the viscous dissipation, and the wall roughness when the Reynolds number exceeded 1000.
- 11 December 2007
- Published by Taylor & Francis in Nanoscale and Microscale Thermophysical Engineering
- Vol. 11 (3-4) , 333-349
An Experimental Investigation of Single-Phase Heat Transfer in 0.045mm to 0.141mm Microtubes
Deioned water, used as the working fluid, flowed through the quartz glass microtubes with inner diameters of 45, 92, and 141 μm, respectively, which was heated by a directly electrifying brass wire coiled evenly up around them. As the Reynolds number varied in the range from 100 up to 3000 in the experiments the corresponding Nussult number was obtained. The experimental results showed that the experimental Nussult numbers were less than predictions of the classical laminar correlations at a lower Reynolds number, which resulted from the effects of the variation of the thermophysical properties with temperature and nonlinear temperature variation of the working fluid along the wall. With the increase of the Reynolds number, the experimental data sharply increased and they were higher than the predictions by the classical transitional correlations due to the conjugate effects of the thinner conductive liquid layer, the entrance length, the viscous dissipation, and the wall roughness when the Reynolds number exceeded 1000.