  • The Relation Between Titanium Taper Corrosion and Cobalt-Chromium Bearing Wear in Large-Head Metal-on-Metal Total Hip Prostheses

    by F. Witt, B.H. Bosker, N.E. Bishop, H.B. Ettema, C.C.P.M. Verheyen, M.M. Morlock

    Background: Revision of hip implants due to adverse tissue reactions to metal debris has been associated with wear and corrosion of the metal-on-metal bearing articulation and the modular taper interface. Bearing articulation wear is increased in conditions of poor lubrication, which can also lead to high friction moments that may cause corrosion at the taper interface. This suggests that wear of the bearing and increased corrosion of the taper interface should occur simultaneously, which was investigated in this study. Methods: Forty-three large-diameter cobalt-chromium bearings of the same design, implanted with a titanium stem using a titanium adapter, were retrieved at revision at a single center. Retrievals were grouped according to visual inspection of the female taper surface of the adapter into slight and severe corrosion groups. Volume change of bearing and taper surfaces was assessed using a coordinate measurement machine. Serum ion concentrations were determined for forty-three patients, whereas tissue metal concentration was measured for twelve patients. Results: Severe taper corrosion was observed in 30% of the retrievals. Corrosion was observed either as material deposition or wear. The overall bearing wear rate was significantly higher in the group with severe taper corrosion than in the group with slight corrosion (7.2 ± 9.0 mm3/yr versus 3.1 ± 6.8 mm3/yr, respectively; p = 0.023) as were the serum cobalt (40.5 ± 44.9 μg/L versus 15.2 ± 23.9 μg/L, respectively; p = 0.024) and chromium ion concentrations (32.7 ± 32.7 μg/L versus 12.0 ± 15.1 μg/L, respectively; p = 0.019). Serum metal ion concentrations were more consistent indicators of wear than tissue metal concentrations. Conclusions: The increased bearing articulation wear and serum metal ion concentrations in cases with taper interface corrosion support the hypothesis that increased friction in the joint articulation is one of the factors responsible for simultaneous articulation and taper damage. However, independent taper or bearing damage was also observed, suggesting that other factors are involved in the process.


  • The influence of bone damage on press-fit mechanics

    by Nicholas E. Bishop, Jan-Christian Höhn, Stephan Rothstock, Niklas B. Damm, Michael M. Morlock


  • Open Access

    Wear patterns of taper connections in retrieved large diameter metal‐on‐metal bearings

    by Nicholas Bishop, Florian Witt, Robin Pourzal, Alfons Fischer, Marcel Rütschi, Markus Michel, Michael Morlock

    Wear of the modular taper between head and shaft has been related to clinical failure resulting from adverse reactions to metallic debris. The problem has become pronounced in large metal‐on‐metal bearings, but the mechanism has not yet been fully understood. We analyzed retrieved components from five patients revised with various diagnoses. Two distinct wear patterns were observed for the head tapers. Three samples demonstrated “asymmetric” wear towards the inner end of the head taper. The other two showed “axisymmetric” radial wear (up to 65 µm) presenting the largest wear volumes (up to 20 mm3). Stem tapers demonstrated relatively little wear, and the fine thread on the stem taper surface was observed to be imprinted on the taper inside of the head. Our findings demonstrate that the cobalt‐chrome head wears preferentially to the titanium stem taper. “asymmetric” wear suggests toggling due to the offset of the joint force vector from the taper. In contrast, samples with “axisymmetric” radial wear and a threaded imprint suggested that corrosion led to head subsidence onto the stem taper with gradual rotation. © 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1116–1122, 2013


  • Open Access

    High friction moments in large hard‐on‐hard hip replacement bearings in conditions of poor lubrication

    by Nicholas E. Bishop, Arne Hothan, Michael M. Morlock

    Disappointing clinical results for large diameter metal replacement bearings for the hip are related to compromised lubrication due to poor cup placement, which increases wear as well as friction moments. The latter can cause overload of the implant–bone interfaces and the taper junction between head and stem. We investigated the influence of lubrication conditions on friction moments in modern hip bearings. Friction moments for large diameter metal and ceramic bearings were measured in a hip simulator with cup angles varying from 0° to 60°. Two diameters were tested for each bearing material, and measurements were made in serum and in dry conditions, representing severely compromised lubrication. Moments were lower for the ceramic bearings than for the metal bearings in lubricated conditions, but approached those for metal bearings at high cup inclination. In dry conditions, friction moments increased twofold to 12 Nm for metal bearings. For ceramic bearings, the increase was more than fivefold to over 25 Nm. Although large diameter ceramic bearings demonstrate an improvement in friction characteristics in the lubricated condition, they could potentially replicate problems currently experienced due to high friction moments in metal bearings once lubrication is compromised. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 807–813, 2013


  • Open Access

    The condition of the Cement Mantle in Femoral Hip Prosthesis Implantations – a Post Mortem Retrieval Study

    by Nicholas E. Bishop, Martin Schönwald, Peter Schultz, Klaus Püschel, Michael M. Morlock

    Despite numerous studies demonstrating the characteristics of the optimal cement mantle in joint replacement, the clinical state of the cement mantle is rarely assessed. A random sample of 214 cemented implated femoral hip components was retrieved post mortem from Hamburg, Germany, and sectioned to investigate the quality of the cement mantle. The most common observation made in at least one measured region per retrieval was debonding (82% of stems), followed by a thin cement mantle (74%), stem-bone contact (48%), soft tissue at the stem interface (44%), no cement-bone interdigitation (30%), a gap at the stem interface (28%), voids in the cement (22%) and cracks and blood in the cement mantle (<10%). 21% of stems demonstrated complete debonding of the interface. However, distributions of all other defects were local, with less than 10% of stems demonstrating any imperfection in more than 21% of the regions assessed. No progressive damage was observed with implantation duration. The results suggest that current implantation technique may be adequate for proper implant function over the service life in the older patient population. However, for younger and more active patients, perfection of the cementation technique is crucial, particularly in modern implant systems such as resurfacing. The frequency of almost all defects could be further reduced by careful implantation technique, providing the increased service life necessary for the ever younger, more physically demanding, patient population.


  • Friction moments of large metal-on-metal hip joint bearings and other modern designs

    by N.E. Bishop, F. Waldow, M.M. Morlock

    Modern hip joint replacements are designed to minimise wear problems. The most popular metal-on-polyethylene components are being updated by harder metal and ceramic combinations. However, this has also been shown to influence the friction moments, which could overload the interface between the implant and the body. In this study custom test apparatus was used to measure the joint moments in various modern bearings under simulated physiological joint conditions. The largest moments in serum were measured for large diameter metal-metal bearings (<8 Nm for standard bearings), followed by metal-polyethylene, and the lowest moments were for small diameter ceramic-ceramic and ceramic-metal combinations. Water as a lubricant was found to double the moments in comparison with serum. In metal-metal bearings moments were reduced by increasing loading frequency. Swing phase load and a rest period between load cycles had little effect. The moment magnitudes are within the turn-out capacity measured for press-fit cups and might become critical with higher joint loads.


  • Assessment of the implant-bone interface in 38 post mortem retrieved femoral components

    by N.E. Bishop, A. Klein, M. Schönwald, M. Hahn, K. Püschel, M.M. Morlock