Nick Cvetojevic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Nick Cvetojevic has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan S. Lawrence
Macquarie University
5 shared publications - Joss Bland-Hawthorn
Sydney Institute for Astronomy, School of Physics , A28, The University of Sydney, NSW 2006
4 shared publications - Michael J. Withford
Macquarie University
3 shared publications Nemanja Jovanovic
Macquarie Univ. (Australia)
3 shared publicationsG. Robertson
School of Physics Sydney Institute for Astronomy (SIfA) University of Sydney 2006 NSW Australia
2 shared publicationsN. Jovanovic
MQ Photonics Research Centre Department of Physics and Astronomy Macquarie University 2109 NSW Australia
2 shared publications
Latest Publications
- 9 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10701, 107010V
GLINT South: A photonic nulling interferometer pathfinder at the Anglo-Australian Telescope for high contrast imaging of substellar companions
With many thousands of exoplanets discovered one of the important next steps in astronomy is to be able to characterise them. This presents a great challenge and calls for new observational capabilities with both high angular resolution and extreme high contrast in order to efficiently separate the bright light of a host star to that of a faint companion. Glint South is an instrument that uses photonic technology to perform nulling interferometry. The light of a star is cancelled out by means of destructive interference in a photonic chip. One of the challenges is the star light injection into the chip. This is done by a unique active system that optimises the injection and provide low order correction for the atmospheric turbulence. We are reporting on the latest progress following several tests on the Anglo Australian Telescope.
- 9 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10701, 107010V
GLINT South: A photonic nulling interferometer pathfinder at the Anglo-Australian Telescope for high contrast imaging of substellar companions
With many thousands of exoplanets discovered one of the important next steps in astronomy is to be able to characterise them. This presents a great challenge and calls for new observational capabilities with both high angular resolution and extreme high contrast in order to efficiently separate the bright light of a host star to that of a faint companion. Glint South is an instrument that uses photonic technology to perform nulling interferometry. The light of a star is cancelled out by means of destructive interference in a photonic chip. One of the challenges is the star light injection into the chip. This is done by a unique active system that optimises the injection and provide low order correction for the atmospheric turbulence. We are reporting on the latest progress following several tests on the Anglo Australian Telescope.
- 24 September 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8446
Redesign of the integrated photonic spectrograph for improved astronomical performance
The Integrated Photonic Spectrograph (IPS) is a complete spectrograph within a single silica photonic chip, that has no moving parts, is highly resistant to stress and temperature induced flexure and is far smaller than existing bulk-optic spectrographs. There has been considerable development in this all-photonic approach, culminating in a recent successful on-telescope test, which saw the world's first astronomical spectra taken using a photonic spectrograph. However, the device's performance (in terms of resolving power and wavelength coverage) was limited by the predominantly telecommunications-grade design parameters used in chip manufacturing, and at this stage warrants a substantial redesign of the arrayed waveguide grating structure inside the IPS chips, to optimize it for astronomy. In this body of work we present a comprehensive redesign of arrayed waveguide grating chips to improve specific performance parameters of interest to astronomy. These include the free-spectral range, resolving power and the operational wavelength for the devices, with an analysis of the limitations and benefits of the redesigns for typical astronomical goals. We propose how the redesigns, along with other advancements in astrophotonics, can be used in conjunction with adaptive-optics systems to make a prototype instrument with competitive throughput and resolving power.
- 24 September 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8446
Redesign of the integrated photonic spectrograph for improved astronomical performance
The Integrated Photonic Spectrograph (IPS) is a complete spectrograph within a single silica photonic chip, that has no moving parts, is highly resistant to stress and temperature induced flexure and is far smaller than existing bulk-optic spectrographs. There has been considerable development in this all-photonic approach, culminating in a recent successful on-telescope test, which saw the world's first astronomical spectra taken using a photonic spectrograph. However, the device's performance (in terms of resolving power and wavelength coverage) was limited by the predominantly telecommunications-grade design parameters used in chip manufacturing, and at this stage warrants a substantial redesign of the arrayed waveguide grating structure inside the IPS chips, to optimize it for astronomy. In this body of work we present a comprehensive redesign of arrayed waveguide grating chips to improve specific performance parameters of interest to astronomy. These include the free-spectral range, resolving power and the operational wavelength for the devices, with an analysis of the limitations and benefits of the redesigns for typical astronomical goals. We propose how the redesigns, along with other advancements in astrophotonics, can be used in conjunction with adaptive-optics systems to make a prototype instrument with competitive throughput and resolving power.
- Open Access
First starlight spectrum captured using an integrated photonic micro-spectrograph
Photonic technologies have received growing consideration for incorporation into next-generation astronomical instrumentation, owing to their miniature footprint and inherent robustness. In this paper we present results from the first on-telescope demonstration of a miniature photonic spectrograph for astronomy, by obtaining spectra spanning the entire H-band from several stellar targets. The prototype was tested on the 3.9 m Anglo-Australian telescope. In particular, we present a spectrum of the variable star Pi 01 Gru, with observed CO molecular absorption bands, at a resolving power R = 2500 at 1600 nm. Furthermore, we successfully demonstrate the simultaneous acquisition of multiple spectra with a single spectrograph chip by using multiple fibre inputs.
Open AccessFirst starlight spectrum captured using an integrated photonic micro-spectrograph
Photonic technologies have received growing consideration for incorporation into next-generation astronomical instrumentation, owing to their miniature footprint and inherent robustness. In this paper we present results from the first on-telescope demonstration of a miniature photonic spectrograph for astronomy, by obtaining spectra spanning the entire H-band from several stellar targets. The prototype was tested on the 3.9 m Anglo-Australian telescope. In particular, we present a spectrum of the variable star Pi 01 Gru, with observed CO molecular absorption bands, at a resolving power R = 2500 at 1600 nm. Furthermore, we successfully demonstrate the simultaneous acquisition of multiple spectra with a single spectrograph chip by using multiple fibre inputs.
- Open Access
- 20 July 2012
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 544, L1
First starlight spectrum captured using an integrated photonic micro-spectrograph
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- 20 July 2012
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 544, L1
Open AccessFirst starlight spectrum captured using an integrated photonic micro-spectrograph
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- Open Access
Developing arrayed waveguide grating spectrographs for multi-object astronomical spectroscopy
With the aim of utilizing arrayed waveguide gratings for multi-object spectroscopy in the field of astronomy, we outline several ways in which standard telecommunications grade chips should be modified. In particular, by removing the parabolic-horn taper or multimode interference coupler, and injecting with an optical fiber directly, the resolving power was increased threefold from 2400 \pm 200 (spectral resolution of 0.63 \pm 0.2 nm) to 7000 \pm 700 (0.22 \pm 0.02 nm) while attaining a throughput of 77 \pm 5%. More importantly, the removal of the taper enabled simultaneous off-axis injection from multiple fibers, significantly increasing the number of spectra that can be obtained at once (i.e. the observing efficiency). Here we report that ~ 12 fibers can be injected simultaneously within the free spectral range of our device, with a 20% reduction in resolving power for fibers placed at 0.8 mm off centre.
Open AccessDeveloping arrayed waveguide grating spectrographs for multi-object astronomical spectroscopy
With the aim of utilizing arrayed waveguide gratings for multi-object spectroscopy in the field of astronomy, we outline several ways in which standard telecommunications grade chips should be modified. In particular, by removing the parabolic-horn taper or multimode interference coupler, and injecting with an optical fiber directly, the resolving power was increased threefold from 2400 \pm 200 (spectral resolution of 0.63 \pm 0.2 nm) to 7000 \pm 700 (0.22 \pm 0.02 nm) while attaining a throughput of 77 \pm 5%. More importantly, the removal of the taper enabled simultaneous off-axis injection from multiple fibers, significantly increasing the number of spectra that can be obtained at once (i.e. the observing efficiency). Here we report that ~ 12 fibers can be injected simultaneously within the free spectral range of our device, with a 20% reduction in resolving power for fibers placed at 0.8 mm off centre.
- 17 January 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (3) , 2062-2072
Developing arrayed waveguide grating spectrographs for multi-object astronomical spectroscopy
With the aim of utilizing arrayed waveguide gratings for multi-object spectroscopy in the field of astronomy, we outline several ways in which standard telecommunications grade chips should be modified. In particular, by removing the parabolic-horn taper or multimode interference coupler, and injecting with an optical fiber directly, the resolving power was increased threefold from 2400 ± 200 (spectral resolution of 0.63 ± 0.2 nm) to 7000 ± 700 (0.22 ± 0.02 nm) while attaining a throughput of 77 ± 5%. More importantly, the removal of the taper enabled simultaneous off-axis injection from multiple fibers, significantly increasing the number of spectra that can be obtained at once (i.e. the observing efficiency). Here we report that ~12 fibers can be injected simultaneously within the free spectral range of our device, with a 20% reduction in resolving power for fibers placed at 0.8 mm off-centre.
- 17 January 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (3) , 2062-2072
Developing arrayed waveguide grating spectrographs for multi-object astronomical spectroscopy
With the aim of utilizing arrayed waveguide gratings for multi-object spectroscopy in the field of astronomy, we outline several ways in which standard telecommunications grade chips should be modified. In particular, by removing the parabolic-horn taper or multimode interference coupler, and injecting with an optical fiber directly, the resolving power was increased threefold from 2400 ± 200 (spectral resolution of 0.63 ± 0.2 nm) to 7000 ± 700 (0.22 ± 0.02 nm) while attaining a throughput of 77 ± 5%. More importantly, the removal of the taper enabled simultaneous off-axis injection from multiple fibers, significantly increasing the number of spectra that can be obtained at once (i.e. the observing efficiency). Here we report that ~12 fibers can be injected simultaneously within the free spectral range of our device, with a 20% reduction in resolving power for fibers placed at 0.8 mm off-centre.
- 16 July 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7735, 77350N
PIMMS: photonic integrated multimode microspectrograph
We present the first integrated multimode photonic spectrograph, a device we call PIMMS #1. The device comprises a set of multimode fibres that convert to single-mode propagation using a matching set of photonic lanterns. These feed to a stack of cyclic array waveguides (AWGs) that illuminate a common detector. Such a device greatly reduces the size of an astronomical instrument at a fixed spectroscopic resolution. Remarkably, the PIMMS concept is largely independent of the telescope diameter, input focal ratio and entrance aperture - i.e. one size fits all! The instrument architecture can also exploit recent advances in astrophotonics (e.g. OH suppression fibres). We present a movie of the instrument's operation and discuss the advantages and disadvantages of this approach.
- 16 July 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7735, 77350N
PIMMS: photonic integrated multimode microspectrograph
We present the first integrated multimode photonic spectrograph, a device we call PIMMS #1. The device comprises a set of multimode fibres that convert to single-mode propagation using a matching set of photonic lanterns. These feed to a stack of cyclic array waveguides (AWGs) that illuminate a common detector. Such a device greatly reduces the size of an astronomical instrument at a fixed spectroscopic resolution. Remarkably, the PIMMS concept is largely independent of the telescope diameter, input focal ratio and entrance aperture - i.e. one size fits all! The instrument architecture can also exploit recent advances in astrophotonics (e.g. OH suppression fibres). We present a movie of the instrument's operation and discuss the advantages and disadvantages of this approach.