Tao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tao Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
J. Ma
Nanyang Technological University
3 shared publicationsJan Ma
Division of Materials Technology, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798
2 shared publicationsY. H. Chen
Nanyang Technological University
2 shared publicationsAdrian F. Low
National University Heart Centre, National University of Singapore, 5 Lower Kent Ridge Road, Singapore 119074
1 shared publicationF. Y. C. Boey
Nanyang Technological University
1 shared publicationF.Y.C. Boey
School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore
1 shared publication
Latest Publications
- Open Access
Piezoelectric Energy Harvesting with an Ultrasonic Vibration Source
A piezoelectric energy harvester was developed in this paper. It is actuated by the vibration leakage from the nodal position of a high-power ultrasonic cutting transducer. The harvester was excited at a low displacement amplitude (0.73 µmpp). However, its operation frequency is quite high and reaches the ultrasonic range (24.4 kHz). Compared with another low frequency harvester (66 Hz), both theoretical and experimental results proved that the advantages of this high frequency harvester include (i) high current generation capability (up to 20 mApp compared to 1.3 mApp of the 66 Hz transducer) and (ii) low impedance matching resistance (500 Ω in contrast to 50 kΩ of the 66 Hz transducer). This energy harvester can be applied either in sensing, or vibration controlling, or simply energy harvesting in a high-power ultrasonic system.
Open AccessPiezoelectric Energy Harvesting with an Ultrasonic Vibration Source
A piezoelectric energy harvester was developed in this paper. It is actuated by the vibration leakage from the nodal position of a high-power ultrasonic cutting transducer. The harvester was excited at a low displacement amplitude (0.73 µmpp). However, its operation frequency is quite high and reaches the ultrasonic range (24.4 kHz). Compared with another low frequency harvester (66 Hz), both theoretical and experimental results proved that the advantages of this high frequency harvester include (i) high current generation capability (up to 20 mApp compared to 1.3 mApp of the 66 Hz transducer) and (ii) low impedance matching resistance (500 Ω in contrast to 50 kΩ of the 66 Hz transducer). This energy harvester can be applied either in sensing, or vibration controlling, or simply energy harvesting in a high-power ultrasonic system.
- Open Access
- 15 May 2012
- Published by Hindawi Limited in ISRN Materials Science
- Vol. 2012, 1-6
Development of Piezoelectric Ultrasonic Thrombolysis Device for Blood Clot Emulsification
Ultrasonic thrombolysis is an effective method to treat blood clot thrombus in a blood vessel. This paper reports an OD 5 mm and an OD 10 mm piezoelectric thrombolysis transducers that vibrate longitudinally and generate a pressure field at the distal vibration tip. Studies of vibration mode, pressure field pattern, and cavitation effect were carried out. The transducers were also tested for blood clot emulsification. The results indicate both transducers are effective. The OD 10 mm transducer with a long transmission wire has shown to provide a strong cavitation effect and work effectively at low frequency, high amplitude, and high power conditions. The OD 5 mm transducer was found to operate effectively under higher frequency, low amplitude, and lower power conditions. The cavitation effect is moderate, which facilitates precision and controls over obtaining a more uniform emulsification result.
- 15 May 2012
- Published by Hindawi Limited in ISRN Materials Science
- Vol. 2012, 1-6
Open AccessDevelopment of Piezoelectric Ultrasonic Thrombolysis Device for Blood Clot Emulsification
Ultrasonic thrombolysis is an effective method to treat blood clot thrombus in a blood vessel. This paper reports an OD 5 mm and an OD 10 mm piezoelectric thrombolysis transducers that vibrate longitudinally and generate a pressure field at the distal vibration tip. Studies of vibration mode, pressure field pattern, and cavitation effect were carried out. The transducers were also tested for blood clot emulsification. The results indicate both transducers are effective. The OD 10 mm transducer with a long transmission wire has shown to provide a strong cavitation effect and work effectively at low frequency, high amplitude, and high power conditions. The OD 5 mm transducer was found to operate effectively under higher frequency, low amplitude, and lower power conditions. The cavitation effect is moderate, which facilitates precision and controls over obtaining a more uniform emulsification result.
- 21 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 56 (3) , 649-659
Development of a miniaturized piezoelectric ultrasonic transducer
A 421 kHz miniaturized piezoelectric ultrasonic transducer for portable and internal body therapeutic applications was developed. The weight, outer diameter, and length of the transducer are 0.15 g, 2 mm, and 10.35 mm, respectively. The transducer is a one-wavelength design based on the longitudinal vibration mode with a stepped horn to focus the energy. Finite element analysis and equivalent circuit models were applied for theoretical analysis. Qm and keff of the transducer measured using the impedance analyzer were 393 and 0.21, respectively. The acoustic output properties of the transducer were measured based on the hydrophone measurements under the condition of 1/4lambda immersion depth. The maximum input electrical power, output acoustic power, sound intensity, radiation pressure, and vibration velocity at the radiation surface were derived to be 0.45 W, 0.11 W, 38 W/cm2, 1.8 MPa, and 2.7 m/s, respectively. The directivity pattern shows that the pressure distribution is omnidirectional within the range from 30 to 150 degrees. The nonlinear effects of ultrasonic streaming in water and cavitation in silicone oil due to the intense ultrasound were also observed. The potential applications of the transducer are sonodynamic therapy, drug delivery, and microfluidic pumping.
- 21 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 56 (3) , 649-659
Development of a miniaturized piezoelectric ultrasonic transducer
A 421 kHz miniaturized piezoelectric ultrasonic transducer for portable and internal body therapeutic applications was developed. The weight, outer diameter, and length of the transducer are 0.15 g, 2 mm, and 10.35 mm, respectively. The transducer is a one-wavelength design based on the longitudinal vibration mode with a stepped horn to focus the energy. Finite element analysis and equivalent circuit models were applied for theoretical analysis. Qm and keff of the transducer measured using the impedance analyzer were 393 and 0.21, respectively. The acoustic output properties of the transducer were measured based on the hydrophone measurements under the condition of 1/4lambda immersion depth. The maximum input electrical power, output acoustic power, sound intensity, radiation pressure, and vibration velocity at the radiation surface were derived to be 0.45 W, 0.11 W, 38 W/cm2, 1.8 MPa, and 2.7 m/s, respectively. The directivity pattern shows that the pressure distribution is omnidirectional within the range from 30 to 150 degrees. The nonlinear effects of ultrasonic streaming in water and cavitation in silicone oil due to the intense ultrasound were also observed. The potential applications of the transducer are sonodynamic therapy, drug delivery, and microfluidic pumping.
- 8 February 2007
- Published by Springer Nature in Journal of Electroceramics
- Vol. 18 (3-4) , 231-242
High amplitude vibration of piezoelectric bending actuators
- 8 February 2007
- Published by Springer Nature in Journal of Electroceramics
- Vol. 18 (3-4) , 231-242
High amplitude vibration of piezoelectric bending actuators
- 14 July 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 134 (2) , 544-554
Domain reorientation of piezoelectric bending actuators
- 14 July 2006
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 134 (2) , 544-554
Domain reorientation of piezoelectric bending actuators
- 1 July 2005
- Published by Springer Nature in Journal of Materials Science
- Vol. 40 (14) , 3601-3605
Characterization of FGM monomorph actuators fabricated using EPD
- 1 July 2005
- Published by Springer Nature in Journal of Materials Science
- Vol. 40 (14) , 3601-3605
Characterization of FGM monomorph actuators fabricated using EPD