Hermann Anetzberger
Research Subjects
Hermann Anetzberger has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Hansjörg Eickhoff
<!--3--> Orthopädie u. Unfallchirurgie, Abteilung Arthroskopie u. Schulterchirurgie GFO‐Kliniken Troisdorf Hospitalstr. 45 53840 Troisdorf Germany
3 shared publications - Michael Mohr
<!--7--> Orthopädisches Zentrum Bad Säckingen Rudolf‐Eberle‐Platz 3 79713 Bad Sackingen Germany
3 shared publications - Roland Becker
Department of Analytical Chemistry and Reference Materials, Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany
3 shared publications - Stephan Reppenhagen
Orthopädische Klinik König-Ludwig-Haus, Lehrstuhl für Orthopädie der Universität Würzburg
3 shared publications - Bernd Döring
<!--5--> Zentrum für Orthopädie und Unfallchirurgie Medizinische Hochschule Theodor Fontane 14770 Brandenburg Germany
2 shared publications - Christof Birkenmaier
LMU Klinikum, Munich, Germany
2 shared publications
Latest Publications
- 8 April 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (1) , 102-113
First validated automated scoring system using the diagnostic arthroscopy skill score (DASS 2.0) for assessing proficiency in virtual reality arthroscopy
Purpose: Proficiency‐based simulator training is a promising approach for learning the complex motor skills required for arthroscopy. However, its implementation requires an objective assessment tool to assess residents' arthroscopic skills. To address this need, an automated diagnostic arthroscopy skill score (DASS) was developed and validated as a replacement for manual scoring. Methods: An automated measurement system of arthroscopic skills was developed, replacing the manual assessment parameters of the DASS with objective measurement criteria. Data from arthroscopies performed by 20 experts were used to establish threshold values for scoring. To validate the new method, 125 videos of residents were recorded and evaluated by five raters. The results of the automated evaluation were then compared with those of established manual assessment. To assess the reliability of the manual evaluation, the intraclass correlation coefficient (ICC) and minimum detectable change (MDC) were calculated. Methodological agreement was evaluated using linear least squares regression and the Bland–Altman method. Results: A good to excellent level of reliability was found among the five raters (ICC for DASS part1 = 0.89, 95% confidence interval [CI] = 0.84–0.92). The calculated MDC was 5.0 points. High methodological agreement was found between the manual and automated evaluations of the DASS. The 95% CI for the slope of the regression line included 1, and the 95% CI for the intercept included 0. According to the Bland–Altman method, the mean difference between manual and automated evaluations was 4.1 ± 5.4 points, and the scattering of the measurement differences was uniformly distributed, regardless of the total score. Conclusions: Automated DASS measurement is a valid and reliable tool for assessing arthroscopic skills. Its advantages, such as rater independence, precise and objective measurements, and immediate evaluation, make it a powerful tool for evaluating arthroscopic performance during simulation training. Level of Evidence: Level II.
- 8 April 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (1) , 102-113
First validated automated scoring system using the diagnostic arthroscopy skill score (DASS 2.0) for assessing proficiency in virtual reality arthroscopy
Purpose: Proficiency‐based simulator training is a promising approach for learning the complex motor skills required for arthroscopy. However, its implementation requires an objective assessment tool to assess residents' arthroscopic skills. To address this need, an automated diagnostic arthroscopy skill score (DASS) was developed and validated as a replacement for manual scoring. Methods: An automated measurement system of arthroscopic skills was developed, replacing the manual assessment parameters of the DASS with objective measurement criteria. Data from arthroscopies performed by 20 experts were used to establish threshold values for scoring. To validate the new method, 125 videos of residents were recorded and evaluated by five raters. The results of the automated evaluation were then compared with those of established manual assessment. To assess the reliability of the manual evaluation, the intraclass correlation coefficient (ICC) and minimum detectable change (MDC) were calculated. Methodological agreement was evaluated using linear least squares regression and the Bland–Altman method. Results: A good to excellent level of reliability was found among the five raters (ICC for DASS part1 = 0.89, 95% confidence interval [CI] = 0.84–0.92). The calculated MDC was 5.0 points. High methodological agreement was found between the manual and automated evaluations of the DASS. The 95% CI for the slope of the regression line included 1, and the 95% CI for the intercept included 0. According to the Bland–Altman method, the mean difference between manual and automated evaluations was 4.1 ± 5.4 points, and the scattering of the measurement differences was uniformly distributed, regardless of the total score. Conclusions: Automated DASS measurement is a valid and reliable tool for assessing arthroscopic skills. Its advantages, such as rater independence, precise and objective measurements, and immediate evaluation, make it a powerful tool for evaluating arthroscopic performance during simulation training. Level of Evidence: Level II.
- 9 June 2023
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (10) , 4231-4238
The number of arthroscopies performed by trainees does not deduce the level of their arthroscopic proficiency
Purpose: It is reasonable to question whether the case volume is a suitable proxy for the manual competence of an arthroscopic surgeon. The aim of this study was to evaluate the correlation between the number of arthroscopies previously performed and the arthroscopic skills acquired using a standardized simulator test.Methods: A total of 97 resident and early orthopaedic surgeons who participated in arthroscopic simulator training courses were divided into five groups based on their self‐reported number of arthroscopic surgeries: (1) none, (2) < 10, (3) 10 to 19, (4) 20 to 39 and (5) 40 to 100. Arthroscopic manual skills were evaluated with a simulator by means of the diagnostic arthroscopy skill score (DASS) before and after training. Seventy‐five points out of 100 must be achieved to pass the test.Results: In the pretest, only three trainees in group 5 passed the arthroscopic skill test, and all other participants failed. Group 5 (57 ± 17 points; n = 17) scored significantly higher than the other groups (group 1: 30 ± 14, n = 20; group 2: 35 ± 14, n = 24; group 3: 35 ± 18, n = 23; and group 4: 33 ± 17, n = 13). After a two‐day simulator training, trainees showed a significant increase in performance. In group 5, participants scored 81 ± 17 points, which was significantly higher than the other groups (group 1: 75 ± 16; group 2: 75 ± 14; group 3: 69 ± 15; and group 4: 73 ± 13). While self‐reported arthroscopic procedures were n.s. associated with higher log odds of passing the test (p = 0.423), the points scored in the pretest were found to be a good predictor of whether a trainee would pass the test (p < 0.05). A positive correlation was observed between the points scored in the pretest and the posttest (p < 0.05, r = 0.59, r2 = 0.34).Conclusions: The number of previously performed arthroscopies is not a reliable indicator of the skills level of orthopaedic residents. A reasonable alternative in the future would be to verify arthroscopic proficiency on the simulator by means of a score as a pass–fail examination.Level of evidence: III.
- 9 June 2023
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (10) , 4231-4238
The number of arthroscopies performed by trainees does not deduce the level of their arthroscopic proficiency
Purpose: It is reasonable to question whether the case volume is a suitable proxy for the manual competence of an arthroscopic surgeon. The aim of this study was to evaluate the correlation between the number of arthroscopies previously performed and the arthroscopic skills acquired using a standardized simulator test.Methods: A total of 97 resident and early orthopaedic surgeons who participated in arthroscopic simulator training courses were divided into five groups based on their self‐reported number of arthroscopic surgeries: (1) none, (2) < 10, (3) 10 to 19, (4) 20 to 39 and (5) 40 to 100. Arthroscopic manual skills were evaluated with a simulator by means of the diagnostic arthroscopy skill score (DASS) before and after training. Seventy‐five points out of 100 must be achieved to pass the test.Results: In the pretest, only three trainees in group 5 passed the arthroscopic skill test, and all other participants failed. Group 5 (57 ± 17 points; n = 17) scored significantly higher than the other groups (group 1: 30 ± 14, n = 20; group 2: 35 ± 14, n = 24; group 3: 35 ± 18, n = 23; and group 4: 33 ± 17, n = 13). After a two‐day simulator training, trainees showed a significant increase in performance. In group 5, participants scored 81 ± 17 points, which was significantly higher than the other groups (group 1: 75 ± 16; group 2: 75 ± 14; group 3: 69 ± 15; and group 4: 73 ± 13). While self‐reported arthroscopic procedures were n.s. associated with higher log odds of passing the test (p = 0.423), the points scored in the pretest were found to be a good predictor of whether a trainee would pass the test (p < 0.05). A positive correlation was observed between the points scored in the pretest and the posttest (p < 0.05, r = 0.59, r2 = 0.34).Conclusions: The number of previously performed arthroscopies is not a reliable indicator of the skills level of orthopaedic residents. A reasonable alternative in the future would be to verify arthroscopic proficiency on the simulator by means of a score as a pass–fail examination.Level of evidence: III.
- Open Access
- 28 February 2022
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 9 (1) , 1-5
Surgical simulation training should become a mandatory part of orthopaedic education
Purpose: Ethical concerns and increasing economic constraints of hospitals have caused a reduction in proper training and education. It has been hypothesized that due to the lack of a one‐to‐one apprenticeship throughout the residency, surgical simulation training is essential.Methods: Between June 2020 and June 2021, residents from teaching hospitals in Switzerland, France, Germany, and Luxembourg were surveyed to learn about their experience with and thoughts on surgical simulation training. Survey responses were analysed using descriptive statistics.Results: Of the 596 residents surveyed, 557 residents (51% female, 49% male) from Switzerland (270), France (214), Germany (52) and Luxembourg (21) agreed to anonymous data analysis. Among those giving consent, 100% considered that simulation training was important for their practical education and 84% thought that simulation training should become a mandatory part of their curriculum, with an average estimated training time of 42 ± 51 h per year, based on the survey.Conclusions: This study suggests that surgical simulation training is well accepted and even demanded among surgical residents as an alternative training solution able to address some of the limitations and challenges of the current one‐to‐one apprenticeship model. There is a wide variation among the residents regarding the number of training hours required, underscoring the need for structured performance‐based simulator training.
- 28 February 2022
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 9 (1) , 1-5
Open AccessSurgical simulation training should become a mandatory part of orthopaedic education
Purpose: Ethical concerns and increasing economic constraints of hospitals have caused a reduction in proper training and education. It has been hypothesized that due to the lack of a one‐to‐one apprenticeship throughout the residency, surgical simulation training is essential.Methods: Between June 2020 and June 2021, residents from teaching hospitals in Switzerland, France, Germany, and Luxembourg were surveyed to learn about their experience with and thoughts on surgical simulation training. Survey responses were analysed using descriptive statistics.Results: Of the 596 residents surveyed, 557 residents (51% female, 49% male) from Switzerland (270), France (214), Germany (52) and Luxembourg (21) agreed to anonymous data analysis. Among those giving consent, 100% considered that simulation training was important for their practical education and 84% thought that simulation training should become a mandatory part of their curriculum, with an average estimated training time of 42 ± 51 h per year, based on the survey.Conclusions: This study suggests that surgical simulation training is well accepted and even demanded among surgical residents as an alternative training solution able to address some of the limitations and challenges of the current one‐to‐one apprenticeship model. There is a wide variation among the residents regarding the number of training hours required, underscoring the need for structured performance‐based simulator training.
- 29 June 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (4) , 1471-1479
Ten hours of simulator training in arthroscopy are insufficient to reach the target level based on the Diagnostic Arthroscopic Skill Score
Purpose: Simulator arthroscopy training has gained popularity in recent years. However, it remains unclear what level of competency surgeons may achieve in what time frame using virtual training. It was hypothesized that 10 h of training would be sufficient to reach the target level defined by experts based on the Diagnostic Arthroscopic Skill Score (DASS).Methods: The training concept was developed by ten instructors affiliated with the German‐speaking Society of Arthroscopy and Joint Surgery (AGA). The programme teaches the basics of performing arthroscopy; the main focus is on learning and practicing manual skills using a simulator. The training was based on a structured programme of exercises designed to help users reach defined learning goals. Initially, camera posture, horizon adjustment and control of the direction of view were taught in a virtual room. Based on these skills, further training was performed with a knee model. The learning progress was assessed by quantifying the exercise time, camera path length and instrument path length for selected tasks. At the end of the course, the learners’ performance in diagnostic arthroscopy was evaluated using DASS. Participants were classified as novice or competent based on the number of arthroscopies performed prior to the assessment.Results: Except for one surgeon, 131 orthopaedic residents and surgeons (29 women, 102 men) who participated in the seven courses agreed to anonymous data analysis. Fifty‐eight of them were competents with more than ten independently performed arthroscopies, and 73 were novices, with fewer than ten independently performed arthroscopies. There were significant reductions in exercise time, camera path length and instrument path length for all participants after the training, indicating a rapid increase in performance. No difference in camera handling between the dominant and non‐dominant sides was found in either group. The competents performed better than the novices in various tasks and achieved significantly better DASS values on the final performance test.Conclusions: Our data have demonstrated that arthroscopic skills can be taught effectively on a simulator, but a 10‐h course is not sufficient to reach the target level set by experienced arthroscopists. However, learning progress can be monitored more objectively during simulator training than in the operating room, and simulation may partially replace the current practice of arthroscopic training.Level of evidence: III.
- 29 June 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (4) , 1471-1479
Ten hours of simulator training in arthroscopy are insufficient to reach the target level based on the Diagnostic Arthroscopic Skill Score
Purpose: Simulator arthroscopy training has gained popularity in recent years. However, it remains unclear what level of competency surgeons may achieve in what time frame using virtual training. It was hypothesized that 10 h of training would be sufficient to reach the target level defined by experts based on the Diagnostic Arthroscopic Skill Score (DASS).Methods: The training concept was developed by ten instructors affiliated with the German‐speaking Society of Arthroscopy and Joint Surgery (AGA). The programme teaches the basics of performing arthroscopy; the main focus is on learning and practicing manual skills using a simulator. The training was based on a structured programme of exercises designed to help users reach defined learning goals. Initially, camera posture, horizon adjustment and control of the direction of view were taught in a virtual room. Based on these skills, further training was performed with a knee model. The learning progress was assessed by quantifying the exercise time, camera path length and instrument path length for selected tasks. At the end of the course, the learners’ performance in diagnostic arthroscopy was evaluated using DASS. Participants were classified as novice or competent based on the number of arthroscopies performed prior to the assessment.Results: Except for one surgeon, 131 orthopaedic residents and surgeons (29 women, 102 men) who participated in the seven courses agreed to anonymous data analysis. Fifty‐eight of them were competents with more than ten independently performed arthroscopies, and 73 were novices, with fewer than ten independently performed arthroscopies. There were significant reductions in exercise time, camera path length and instrument path length for all participants after the training, indicating a rapid increase in performance. No difference in camera handling between the dominant and non‐dominant sides was found in either group. The competents performed better than the novices in various tasks and achieved significantly better DASS values on the final performance test.Conclusions: Our data have demonstrated that arthroscopic skills can be taught effectively on a simulator, but a 10‐h course is not sufficient to reach the target level set by experienced arthroscopists. However, learning progress can be monitored more objectively during simulator training than in the operating room, and simulation may partially replace the current practice of arthroscopic training.Level of evidence: III.
- 17 June 2021
- Published by Springer Nature in Arthroskopie
- Vol. 34 (4) , 1-5
Kniearthroskopie in Lokalanästhesie
- 17 June 2021
- Published by Springer Nature in Arthroskopie
- Vol. 34 (4) , 1-5
Kniearthroskopie in Lokalanästhesie
- 29 April 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (1) , 349-360
The Diagnostic Arthroscopy Skill Score (DASS): a reliable and suitable assessment tool for arthroscopic skill training
Purpose: To develop and validate a novel score to more objectively assess the performance of diagnostic knee arthroscopy using a simulator.Methods: A Diagnostic Arthroscopy Skill Score (DASS) was developed by ten AGA (AGA‐Society for Arthroscopy and Joint‐Surgery) instructors for the assessment of arthroscopic skills. DASS consists of two parts: the evaluation of standardized diagnostic knee arthroscopy (DASSpart1) and the evaluation of manual dexterity, including ambidexterity and triangulation, using objective measurement parameters (DASSpart2). Content validity was determined by the Delphi method. One hundred and eleven videos of diagnostic knee arthroscopies were recorded during simulator training courses and evaluated by six specially trained instructors using DASS. Construct validity, measurement error calculated by the minimum detectable change (MDC), internal consistency using Cronbach’s alpha and interrater and intrarater reliability were assessed. The Bland–Altman method was used to calculate the intrarater agreement.Results: Six skill domains were identified and evaluated for each knee compartment. DASS, DASSpart1, and DASSpart2 showed construct validity, with experts achieving significantly higher scores than competents and novices. MDC was 4.5 ± 1.7 points for DASSpart1. There was high internal consistency for all domains in each compartment from 0.78 to 0.86. The interrater reliability showed high agreement between the six raters (ICC = 0.94). The evaluation of intrarater reliability demonstrated good and excellent agreement for five raters (ICC > 0.80) and moderate agreement for one rater (ICC = 0.68). The Bland–Altman comparison showed no difference between the first and second evaluations in five out of six raters. Precision, estimated by the regression analysis and comparison with the method of Bland and Altman, was excellent for four raters and moderate for two raters.Conclusions: The results of this study indicate good validity and reliability of DASS for the assessment of the surgical performance of diagnostic knee arthroscopy during simulator training. Standardized training is recommended before arthroscopy surgery is considered in patients.Level of evidence: II.
- 29 April 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (1) , 349-360
The Diagnostic Arthroscopy Skill Score (DASS): a reliable and suitable assessment tool for arthroscopic skill training
Purpose: To develop and validate a novel score to more objectively assess the performance of diagnostic knee arthroscopy using a simulator.Methods: A Diagnostic Arthroscopy Skill Score (DASS) was developed by ten AGA (AGA‐Society for Arthroscopy and Joint‐Surgery) instructors for the assessment of arthroscopic skills. DASS consists of two parts: the evaluation of standardized diagnostic knee arthroscopy (DASSpart1) and the evaluation of manual dexterity, including ambidexterity and triangulation, using objective measurement parameters (DASSpart2). Content validity was determined by the Delphi method. One hundred and eleven videos of diagnostic knee arthroscopies were recorded during simulator training courses and evaluated by six specially trained instructors using DASS. Construct validity, measurement error calculated by the minimum detectable change (MDC), internal consistency using Cronbach’s alpha and interrater and intrarater reliability were assessed. The Bland–Altman method was used to calculate the intrarater agreement.Results: Six skill domains were identified and evaluated for each knee compartment. DASS, DASSpart1, and DASSpart2 showed construct validity, with experts achieving significantly higher scores than competents and novices. MDC was 4.5 ± 1.7 points for DASSpart1. There was high internal consistency for all domains in each compartment from 0.78 to 0.86. The interrater reliability showed high agreement between the six raters (ICC = 0.94). The evaluation of intrarater reliability demonstrated good and excellent agreement for five raters (ICC > 0.80) and moderate agreement for one rater (ICC = 0.68). The Bland–Altman comparison showed no difference between the first and second evaluations in five out of six raters. Precision, estimated by the regression analysis and comparison with the method of Bland and Altman, was excellent for four raters and moderate for two raters.Conclusions: The results of this study indicate good validity and reliability of DASS for the assessment of the surgical performance of diagnostic knee arthroscopy during simulator training. Standardized training is recommended before arthroscopy surgery is considered in patients.Level of evidence: II.
- 15 January 2021
- Published by Springer Nature in Arthroskopie
- Vol. 34 (2) , 103-117
Drei Jahre AGA Simulatortraining Arthroskopie
- 15 January 2021
- Published by Springer Nature in Arthroskopie
- Vol. 34 (2) , 103-117
Drei Jahre AGA Simulatortraining Arthroskopie
- 18 September 2013
- Published by Springer Nature in Obere Extremität
- Vol. 8 (4) , 212-219
Der passive Bewegungsumfang von gesunden Schultern
- 18 September 2013
- Published by Springer Nature in Obere Extremität
- Vol. 8 (4) , 212-219
Der passive Bewegungsumfang von gesunden Schultern
- 16 November 2012
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (1) , 112-119
Meniscectomy leads to early changes in the mineralization distribution of subchondral bone plate
Purpose: It is generally recognized that the subchondral bone plate (SBP) is involved in development of osteoarthritis (OA). However, the pathophysiological significance is not yet clear. The goal of this study is to investigate the extent of the changes that occur in SBP of the tibial plateau in the early stages of experimental OA.Methods: Forty‐three female rabbits were assigned to 5 experimental (n = 8 each group) and one sham group (n = 3). OA was induced by medial meniscectomy in the right knee, the left knee served as control. 2, 4, 8, 12, and 24 weeks after meniscectomy, cartilage damage was evaluated, and bone mineral density (BMD) and mineralization distribution of the SBP was measured by computed tomography osteoabsorptiometry (CT‐OAM).Results: Cartilage damage started 2 weeks after meniscectomy with surface roughening. Cartilage defects increased over time. 24 weeks postoperatively, subchondral bone was exposed. As early as 2 weeks after meniscectomy, BMD in the medial tibial plateau decreased significantly. BMD increased again and reached the values of the non‐operated knee 12 weeks postoperatively. In addition, already 4 weeks after meniscectomy a significant shift of the densitiy maximum on the medial tibial plateau, which is normally centrally located toward the margin was observed.Conclusions: In conclusion, the results of this study contribute to the concept of early involvement of the SBP in the development of OA. The hypothesis that changes in the SBP occur simultaneously to cartilage damage was confirmed.
- 16 November 2012
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (1) , 112-119
Meniscectomy leads to early changes in the mineralization distribution of subchondral bone plate
Purpose: It is generally recognized that the subchondral bone plate (SBP) is involved in development of osteoarthritis (OA). However, the pathophysiological significance is not yet clear. The goal of this study is to investigate the extent of the changes that occur in SBP of the tibial plateau in the early stages of experimental OA.Methods: Forty‐three female rabbits were assigned to 5 experimental (n = 8 each group) and one sham group (n = 3). OA was induced by medial meniscectomy in the right knee, the left knee served as control. 2, 4, 8, 12, and 24 weeks after meniscectomy, cartilage damage was evaluated, and bone mineral density (BMD) and mineralization distribution of the SBP was measured by computed tomography osteoabsorptiometry (CT‐OAM).Results: Cartilage damage started 2 weeks after meniscectomy with surface roughening. Cartilage defects increased over time. 24 weeks postoperatively, subchondral bone was exposed. As early as 2 weeks after meniscectomy, BMD in the medial tibial plateau decreased significantly. BMD increased again and reached the values of the non‐operated knee 12 weeks postoperatively. In addition, already 4 weeks after meniscectomy a significant shift of the densitiy maximum on the medial tibial plateau, which is normally centrally located toward the margin was observed.Conclusions: In conclusion, the results of this study contribute to the concept of early involvement of the SBP in the development of OA. The hypothesis that changes in the SBP occur simultaneously to cartilage damage was confirmed.
- 26 June 2012
- Published by S. Karger AG in European Surgical Research
- Vol. 48 (4) , 208-214
Computed Tomography Osteoabsorptiometry Is Reliable for the Determination of the Subchondral Bone Mineralization Distribution in the Rabbit Knee
Rabbits are among the most frequently used animals in osteoarthritis research. It is meanwhile accepted that the subchondral bone plate (SBP) plays a key role in the development of osteoarthritis. The most suitable technique for analyzing subchondral bone mineralization is computed tomography osteoabsorptiometry (CT-OAM). Because CT-OAM has not yet been applied to smaller animals, the purpose of this study is to test the reliability of CT-OAM in the rabbit knee. Another important task in animal experiments is the intra- and interindividual difference of the measurement parameters. Our hypothesis is that there is no difference regarding both the position of the density maxima and the bone mineral density (BMD) of the SBP comparing right and left tibial plateaus of rabbits. For evaluating the reliability, a rabbit knee was examined by computed tomography 6 times at weekly intervals. The subchondral mineralization distribution was measured by means of CT-OAM. Positions of the density maxima and BMD of the SBP were determined in a standardized procedure. Furthermore, both parameters were evaluated in 6 female White New Zealand rabbits. Positions of density maxima and BMD in the SBP in left tibial plateaus were compared with right tibial plateaus. The relative coefficient of variation as a parameter for reproducibility was 1.6% for determining the position of the density maxima and 1.2% for measuring the BMD. The positions of density maxima and relative BMD between right and left tibial plateaus varied only about 2% intraindividually, whereas interindividual variance was about 10%. In conclusion, determination of the position of density maxima as well as BMD of the SBP by means of CT-OAM is reliable and reproducible in the rabbit knee. We recommend using the contralateral limb as control, because intraindividual accordance of the mineralization patterns and of the BMD of the SBP was higher than interindividual accordance.
- 26 June 2012
- Published by S. Karger AG in European Surgical Research
- Vol. 48 (4) , 208-214
Computed Tomography Osteoabsorptiometry Is Reliable for the Determination of the Subchondral Bone Mineralization Distribution in the Rabbit Knee
Rabbits are among the most frequently used animals in osteoarthritis research. It is meanwhile accepted that the subchondral bone plate (SBP) plays a key role in the development of osteoarthritis. The most suitable technique for analyzing subchondral bone mineralization is computed tomography osteoabsorptiometry (CT-OAM). Because CT-OAM has not yet been applied to smaller animals, the purpose of this study is to test the reliability of CT-OAM in the rabbit knee. Another important task in animal experiments is the intra- and interindividual difference of the measurement parameters. Our hypothesis is that there is no difference regarding both the position of the density maxima and the bone mineral density (BMD) of the SBP comparing right and left tibial plateaus of rabbits. For evaluating the reliability, a rabbit knee was examined by computed tomography 6 times at weekly intervals. The subchondral mineralization distribution was measured by means of CT-OAM. Positions of the density maxima and BMD of the SBP were determined in a standardized procedure. Furthermore, both parameters were evaluated in 6 female White New Zealand rabbits. Positions of density maxima and BMD in the SBP in left tibial plateaus were compared with right tibial plateaus. The relative coefficient of variation as a parameter for reproducibility was 1.6% for determining the position of the density maxima and 1.2% for measuring the BMD. The positions of density maxima and relative BMD between right and left tibial plateaus varied only about 2% intraindividually, whereas interindividual variance was about 10%. In conclusion, determination of the position of density maxima as well as BMD of the SBP by means of CT-OAM is reliable and reproducible in the rabbit knee. We recommend using the contralateral limb as control, because intraindividual accordance of the mineralization patterns and of the BMD of the SBP was higher than interindividual accordance.