Latest Publications

  • Coupling- and Persistent-Current Magnetizations of $ \hbox{Nb}_{3}\hbox{Sn}$ Rutherford Cables With Cores of Stainless Steel and Woven Glass-Fiber Tape Measured by Pick-Up Coil Magnetometry

    by E. W. Collings, M. D. Sumption, M. A. Susner, D. R. Dietderich, E. Kroopshoop, A. Nijhuis

    Coupling- and persistent-current magnetization of $hbox{Nb}_{3}hbox{Sn}$ Rutherford cables with cores of stainless steel (SS) and woven glass-fiber tape were measured by pick-up coil magnetometry in transverse magnetic fields of amplitude 400 mT and frequencies of up to 90 mHz applied in the face-on orientation. Analysis of the results yielded the interstrand contact resistances as well as estimates of the face-on coupling magnetizations generated by fields ramping at the LHC-specified 6.5 mT/s. Distinct differences were discovered in the behaviors of the SS-cored and glass-fiber-cored cables. The cable with a wide SS core had suitable coupling properties; that with a narrow off-center SS core provided excessively large coupling magnetization. The glass-fiber-cored cables exhibited anomalous ac-loss frequency dependence indicative of loose Rutherford-like assemblies of strands with relatively few points of low-resistance interstrand contact.


  • A model superconducting helical undulator fabricated using a small filament, tube-type, multifilamentary Nb3Sn wire

    by M Majoros, M D Sumption, M A Susner, C Kovacs, E W Collings, X Peng, D Doll, M Tomsic, D Lyons


  • Stability and Normal Zone Propagation in a 50 Tesla Solenoid Wound of YBCO Coated Conductor Tape—FEM Modeling

    by M. Majoros, M. D. Sumption, E. W. Collings

    We present an analysis of stability, heating and quench propagation in a 50 Tesla solenoid immersed in a liquid helium bath at 4.2 K, obtained by numerical Finite Element Method (FEM) modeling. The solenoid was assumed to be wound of a cable made of YBCO coated conductor tapes. Full heat transfer curve in the whole temperature range (from 4.2 K up to 300 K) for liquid helium, taken from experiment, was used. An anisotropic continuum model of the winding for thermal propagation, with input data taken from experiments, was developed and adopted in computations. Magnetic field and temperature dependent parameters, such as electrical and thermal conductivities, heat capacities etc., also taken from experiments, were considered. We modeled a single-coil 50 T solenoid as well as a segment approach, in which a 34 T winding, segmented radially, is the inner-most part of a system of and NbTi solenoids providing a background field of 16 Tesla. Stress-strain modeling showed that due to a strong anisotropy of in YBCO film, the critical current of the solenoid is not limited by mechanical forces, but by the radial magnetic field component in the winding, i.e. by the field component parallel to c-axis of YBCO film. We found quite a high degree of stability of the 50 Tesla solenoid with existing stagnant normal zones and significant heat conduction across the winding.


  • Transport, Magnetic, and SEM Characterization of a Novel Design Bi-2212 Strand

    by C. S. Myers, M. A. Susner, L. Motowidlo, J. Distin, M. D. Sumption, E. W. Collings

    In this work, a new strand design for Bi-2212 conductors was studied. The new design had a single stack approach with randomly oriented but densely packed two-dimensional Bi-2212 filaments. This Bi-2212 Two-Dimensional Random-Oriented Single-Stack (2D-ROSS) Round Wire design led to high levels of grain texture and significant amounts of Ag-superconductor interface within the filaments, while maintaining a high strand fill factor. This new design was compared to a strand made with a conventional billet layout. Heat treatments were performed under 100% flowing oxygen, and the samples were melt processed at 884, 886, 888, and 89°C. The strands were studied via transport, magnetic, and electron optics techniques. The strands manufactured with the new process showed higher critical currents than the standard design strands in terms of engineering critical current density (Je) but slightly lower layer critical current density (Jc). However both strand sets were limited by filament sizes which were not yet optimized and excessive C-content in the powders. Je values of 48 A/mm2 for the new strand design, and 26 A/mm2 for the conventional double stack design, at 12 T and 4.2 K were observed. An interesting property of the new strand method was that the strands were less sensitive to small heat treatment, HT, temperature variations in terms of their final Jc properties. Magnetic and microstructure/phase assemblage studies observed less filament bridging in the new strand design as compared to the conventional one.


  • COUPLING-CURRENT AND PERSISTENT-CURRENT MAGNETIZATIONS IN Nb[sub 3]Sn RUTHERFORD CABLES AND STRANDS

    by E. W. Collings, M. D. Sumption, M. A. Susner, D. R. Dietderich, E. Barzi, A. V. Zlobin, A. Nijhuis, U. (Balu) Balachandran

    Calorimetric and magnetic measurements of AC loss in Nb3Sn Rutherford cables were accompanied by magnetic measurements of persistent‐current (hysteretic) loss in strands extracted from those cables. From the cable‐loss measurements it is shown that the introduction of a stainless steel core increases the effective interstrand contact resistance (ICR), initially 0.3 μΩ, by more than two orders of magnitude. Uniaxial pressure applied to the cable during winding and subsequently, seemingly by reducing side‐by‐side contact, increased the ICR. In an edge‐on applied AC field the persistent‐current cable loss was fully accounted for in terms of the individual‐strand loss. The persistent‐current loss measured for the cable in a face‐on applied field was higher that that in an edge‐on applied field, this may have been due to demagnetization effects.

  • Transport AC Loss Reduction in Striated YBCO Coated Conductors by Magnetic Screening

    by Milan Majoros, Sumption, Edward W. Collings

    It is known from our previous work that magnetic screening is an effective way of decoupling the strands in striated YBCO coated conductors. Different configurations of multifilament geometry with filaments embedded in ferromagnetic materials of different thickness and different magnetic permeability have been modeled in the past and a reduction of transport ac loss predicted by FEM calculations. In the present work we propose a much simpler and more practical method for magnetic decoupling of the strands in YBCO coated conductors. This method consists in filling just the inter-filamentary space between the filaments by a ferromagnetic material, rather than embedding the filaments completely. Calculations of transport ac loss reduction were performed using a finite element method. A comparison of the loss reduction of this new geometry with previous results (assuming filaments completely surrounded by ferromagnetic material) as well as the case of perfect screening were made. Due to the "flat" (nearly 2D) geometry of striated YBCO coated conductors the present method gives almost the same transport ac loss reduction as completely embedding the filaments in a ferromagnetic material.


  • WIND AND REACT MgB[sub 2] ROTOR COILS

    by S. D. Bohnenstiehl, M. D. Sumption, M. Majoros, M. Tomsic, M. Rindfleisch, J. Phillips, J. Yue, E. W. Collings, U. (Balu) Balachandran, Kathleen Amm, et al.

    Five rotor coils (four plus a spare) intended for a prototype 2 MW generator were fabricated and tested. For each coil, multifilamentary MgB2 strand was wound around a stepped former in a wind and react mode using S‐glass insulation in combination with vacuum epoxy impregnation. The stepped, ellipsoidal coils had maximum in‐plane dimensions of 26.7 cm×13.1 cm and a total thickness of 5.4 cm, and were wound with approximately 580 m of MgB2 strand per coil. Each of the coils were measured separately for Ic and magnetic field in the bore at 4.2 K and for one coil Ic and B were also measured as a function of temperature. The bore field as a function of position along the z‐axis was also determined near the critical current at 4.2 K. The coils typically reached 186 A at 4.2 K generating a 1.7 T field, while at 20 K the Ic was 117 A with a bore field of 1.1 T field.


  • Composition Profiles and Upper Critical Field Measurement of Internal-Sn and Tube-Type Conductors

    by X. Peng, M. D. Sumption, R. Dhaka, M. Bhatia, M. Tomsic, E. Gregory, E. W. Collings

    Two standard internal-Sn type rod-in-tube (RIT) and two newly developed tube type conductors were investigated. Both types of strand were doped with Ta. A series of heat-treatments with varying temperature and duration time were performed to study their influence on the microstructure and properties. In this work, the fully reacted strands were analysed. Non-Cu Jc was measured and Bc2 values were estimated via Kramer plot extrapolation. Bc2 values were also measured by resistive transitions at high magnetic fields, and compared with the values from Kramer plot extrapolations. High resolution scanning electron microscopy (SEM) was used to observe the cross-section and the composition across the strands' cross-section was measured by using energy dispersive spectroscopy (EDS). scanning transmission electron microscopy (STEM) was used to measure the composition variation in the individual filaments in the RIT strands. Superconducting properties were correlated to strand composition.


  • Modeling of Transport AC Losses in Superconducting Arrays Carrying Anti-Parallel Currents

    by M. Majoros, L. Ye, A. M. Campbell, T. A. Coombs, M. D. Sumption, E. W. Collings

    Transport ac losses of parallel arrays of superconducting tapes with an elliptical cross-section carrying mutually anti-parallel currents were modeled numerically by finite element method. Two different configurations-tapes positioned edge to edge (x-array) and tapes positioned face to face (y-array) were considered. It was found that an x-array increases the losses while a y-array decreases them-relative to infinitely distant tapes. The highest ac loss decrease is observed when the tapes are close to each other in y-array. The AC loss of a y-array made of various numbers of tapes was compared with the loss of an array made of round wires. It was found that y-arrays of tapes have lower loss than arrays of round wires. Bringing y-arrays of tapes close to each other in the x direction causes a significant increase in ac loss. The present analysis may be useful if considering fault current limiters made of straight conductors in a meandering configuration. The results are qualitatively valid also for a fault current limiter made of non-inductive (bifilar) windings in the form of several pancake coils, each coil wound non-inductively (i.e. with anti-parallel currents).


  • Geometry dependence of magnetic and transport AC losses in Bi-2223/Ag tapes with different aspect ratios

    by X M Luo, D X Chen, A K M Alamgir, E W Collings, E Lee, M D Sumption, J G Fang, H P Yi, X H Song, S Q Guo, et al.