MBMarie-Emmanuelle Behr-Gross

Marie-Emmanuelle Behr-Gross

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marie-Emmanuelle Behr-Gross has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Recommendations of the VAC2VAC workshop on the design of multi-centre validation studies

    by Marlies Halder, Hilde Depraetere, Frédérique Delannois, Arnoud Akkermans, Marie-Emmanuelle Behr-Gross, Martijn Bruysters, Jean-François Dierick, Carmen Jungbäck, Imke Kross, Bernard Metz, et al.


    • 1 January 2016
      • Vol. 2016, 115-28

    Interpretation of size-exclusion chromatography for the determination of molecular-size distribution of human immunoglobulins.

    by S Christians, S Schluender, N D Van Treel, M-E Behr-Gross

    Molecular-size distribution by size-exclusion chromatography (SEC) [1] is used for the quantification of unwanted aggregated forms in therapeutic polyclonal antibodies, referred to as human immunoglobulins (Ig) in the European Pharmacopoeia. Considering not only the requirements of the monographs for human normal Ig (0338, 0918 and 2788) [2-4], but also the general chapter on chromatographic techniques (2.2.46) [5], several chromatographic column types are allowed for performing this test. Although the EDQM knowledge database gives only 2 examples of suitable columns as a guide for the user, these monographs permit the use of columns with different lengths and diameters, and do not prescribe either particle size or pore size, which are considered key characteristics of SEC columns. Therefore, the columns used may differ significantly from each other with regard to peak resolution, potentially resulting in ambiguous peak identity assignment. In some cases, this may even lead to situations where the manufacturer and the Official Medicines Control Laboratory (OMCL) in charge of Official Control Authority Batch Release (OCABR) have differing molecular-size distribution profiles for aggregates of the same batch of Ig, even though both laboratories follow the requirements of the relevant monograph. In the present study, several formally acceptable columns and the peak integration results obtained therewith were compared. A standard size-exclusion column with a length of 60 cm and a particle size of 10 µm typically detects only 3 Ig fractions, namely monomers, dimers and polymers. This column type was among the first reliable HPLC columns on the market for this test and very rapidly became the standard for many pharmaceutical manufacturers and OMCLs for batch release testing. Consequently, the distribution of monomers, dimers and polymers was established as the basis for the interpretation of the results of the molecular-size distribution test in the relevant monographs. However, modern columns with a smaller particle size provide better resolution and also reveal a class of components designated here as oligomers. This publication addresses the interpretation of the SEC test for Ig with respect to the following questions: - how can molecular-size distribution tests benefit from the use of the most recent column technology without changing the sense of well-established quality parameters? - is it possible to mathematically define a way to interpret chromatograms generated with various column types with the same fractionation range but different resolution power? - how should oligomers be considered regarding compliance with compendial specifications?


    • 1 January 2015
      • Vol. 2015, 181-9

    Establishment of the human albumin for electrophoresis Ph. Eur. BRP batches 3 and 4.

    by M-E Behr-Gross, A Daas, A Eulig-Wien, S Christians

    Due to the diminished stocks of the 2nd batch of the European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation (BRP) for human albumin for electrophoresis, the European Directorate for the Quality of Medicines & HealthCare (EDQM) initiated in 2014 an international collaborative study for the establishment of two replacement batches. The study was run under the aegis of the Biological Standardisation Programme (BSP). Thirteen laboratories participated in the collaborative study to verify the suitability of the candidate reference preparations according to the Ph. Eur. monograph 0255 using the zone electrophoresis (ZE) method with either cellulose acetate and/or agarose as the testing medium. The candidate preparations were found suitable for the intended purpose and were subsequently adopted in June 2015 by the Ph. Eur. Commission as human albumin for electrophoresis BRP batches 3 and 4 with an assigned range for albumin of 93.8 per cent to 98.3 per cent of the total protein content.

    • 1 January 2014
      • Vol. 2014, 71-80

    Collaborative study for the establishment of the human immunoglobulin for electrophoresis Ph. Eur. BRP batch 3.

    by M-E Behr-Gross, A Daas, S Christians

    Due to the diminished stocks of the 2(nd) batch of the European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation (BRP) for human immunoglobulin for electrophoresis, in 2013, the European Directorate for the Quality of Medicines and HealthCare (EDQM) initiated an international collaborative study for the establishment of a replacement batch. The study was run under the aegis of the Biological Standardisation Programme (BSP). Seventeen laboratories participated in the collaborative study to verify the suitability of the candidate reference preparation according to the Ph. Eur. monographs 0338 and 0918 using the zone electrophoresis (ZE) method with either cellulose acetate and/or agarose as the testing medium. The candidate preparation was found suitable for the intended purpose and was subsequently adopted by the Ph. Eur. Commission as the human immunoglobulin for electrophoresis BRP batch 3 with an assigned range for immunoglobulin of 79.8 % to 86.4 % of the total protein content.

    • 1 April 2010
      • Vol. 2010  (1) , 51-63

    Collaborative study for the standardisation of the histamine sensitizing test in mice and the CHO cell-based assay for the residual toxicity testing of acellular pertussis vaccines.

    by D Xing, A Maes, M-E Behr-Gross, A Costanzo, A Daas, K-H Buchheit

    The European Pharmacopoeia (Ph. Eur.) and the World Health Organisation (WHO) require the performance of extensive quality and safety control testing before the release on the market of vaccine products for human use. Safety testing with regard to residual pertussis toxin (PT) in acellular pertussis combination vaccines is performed through assessment of fatal sensitisation of mice to histamine challenge by the vaccine product under test. Currently, use of different in-house procedures and no requirement for the inclusion of a standard reference in each assay render comparisons of results obtained for identical vaccine batches between different control laboratories very difficult. At the initiative of the European Directorate for the Quality of Medicines and HealthCare (EDQM), an international collaborative study was organised for the standardization of the Histamine Sensitizing Test (HIST) in mice and the Chinese Hamster Ovary (CHO)-cell-based assay (performed at the bulk product level) for the residual toxicity testing of acellular pertussis vaccines or acellular pertussis-based combination vaccines. The study was run under the aegis of the Biological Standardisation Programme, jointly supported by the Council of Europe and the European Commission under the project code BSP076. Ten (10) laboratories participated in the study and were requested to perform 3 independent Histamine Sensitizing Tests in mice and to report results of the lethal end-point measurement as prescribed by the Ph. Eur. monographs. Some of them also reported data from an in-house validated CHO-cell-based assay. In addition, some of the laboratories reported concomitantly data obtained by measurement of the drop in temperature induced after the histamine challenge, a method currently under investigation to be added as an alternative end-point for the HIST in the Ph. Eur. monographs for acellular pertussis-based combination vaccines in order to alleviate animal suffering (in application of the 3Rs principle). Based on the results of the collaborative study, a potency of 7500 IU/vial (International Units per vial) was assigned to the current Ph. Eur. Biological Reference Preparation (BRP) for PT. The results of the study also show that 1) intra- and inter-laboratory variations can be improved by the use of a validated standard operating procedure; 2) inclusion in each assay of a standard reference sample, calibrated in IU, can increase comparability of results among laboratories and thus help to reduce repeat testing; 3) a correlation between mortality data and temperature data was observed although, due to the limited number of data sets and the lack of a common method for the temperature end-point, further investigation of this point is required; 4) the CHO-cell-based assay did not yield comparable results and further standardisation of the assay procedure may be investigated in a follow-up project.


    • 1 October 2009
      • Vol. 2009  (1) , 27-40

    Collaborative study on a Guinea pig serological method for the assay of acellular pertussis vaccines.

    by R Winsnes, D Sesardic, A Daas, E Terao, M-E Behr-Gross

    An international collaborative study (coded BSP083) was performed under the aegis of the Biological Standardisation Programme supported by the Council of Europe and the European Commission, with the aim of replacing the in vivo challenge assays for potency determination of combined acellular pertussis (aP) vaccines by a refined procedure also allowing reduction of animal use. This study investigates whether the immunogenicity of aP vaccine components could be assayed in a guinea pig (gp) serology model, using the same vaccine immunising doses as for D and T components potency testing, instead of using separate animals as is currently done. The BSP83 project is a follow up of 3 former collaborative studies (coded BSP019, BSP034 and BSP035) on serological methods for the potency testing of tetanus (T) and diphtheria (D) vaccines for human use. The use of gp instead of mice serology has the advantage of providing a larger volume of good quality antiserum for the assay of several vaccine components in the same sample, hence providing the opportunity for animal sparing. The results of Phase I of the study demonstrated that gp serology may be a useful method for the immunogenicity assay of acellular pertussis vaccines. This was confirmed in Phase II of the study, using 7 different combined aP vaccines in an international collaborative study involving 17 laboratories from both public and private sectors. Clear dose-response relationships were observed for different vaccines by ELISA, for antibodies against aP antigens, i.e. pertussis toxin (PT), filamentous haemagglutinin (FHA), fimbrial agglutinogens-2/3 (Fim 2/3) and pertactin (PRN). Intra- and inter-laboratory variations of aP ELISA results were found to be within an acceptable range. For some combined vaccines, however, the range of vaccine dilutions for immunisation confirmed to be optimal for D and T potency testing may not provide optimal dose-response for all aP components. Method adjustments may thus be required and suitability should therefore be demonstrated for each vaccine combination and product prior to the application of this assay. The results of this study support the use of the gp serological method for the determination of the immunogenicity of aP vaccines. The application of the method for batch release testing of combined D, T and aP vaccines could significantly contribute to the implementation of the 3R principles through reduction of animal use and improved animal welfare, whilst reducing costs. As an outcome of this study, the Group of Experts No. 15 on Sera and Vaccines of the European Pharmacopoeia (Ph. Eur.) decided in February 2009 to include the gp serological assay as an example in the Ph. Eur. General chapter 2.7.16. on acellular pertussis vaccine assay.


    • 1 December 2008
      • Vol. 2008  (1) , 1-6

    Establishment of replacement batches for prekallikrein activator in albumin biological reference preparation.

    by F Lackner, A Daas, E Terao, M-E Behr-Gross

    A collaborative study was run by the European Directorate for the Quality of Medicines and HealthCare (EDQM) under the aegis of the Biological Standardisation Programme (BSP) to establish replacement batches of the current Prekallikrein activator in albumin Biological Reference Preparation (BRP) batch 1, the stocks of which were dwindling. Candidate BRP replacement batch 2 and batch 3 were assayed against the 2nd World Health Organization International Standard for Prekallikrein activator, human (2nd IS) and the Prekallikrein activator in albumin BRP batch 1. The candidate batches were manufactured from the same starting material as the current Biological Reference Preparation and the 2nd IS. They consisted of a 20 % solution of albumin lyophilised under the same conditions as the Prekallikrein activator in albumin BRP batch 1. Sixteen laboratories participated in the collaborative study and were requested to assay the candidates by their routine method, complying with the European Pharmacopoeia (Ph. Eur.) general method 2.6.15 for the determination of prekallikrein activator content. A central statistical analysis was performed at the EDQM using in-house calculations of prekallikrein activator contents provided by the participating laboratories. On the basis of the results of this study, which confirmed the assigned potency of 29 IU/vial of Prekallikrein activator in albumin BRP batch 1, the 2 candidate materials were assigned a potency of 30 IU/vial. The 2 candidates were adopted by the Ph. Eur. Commission in March 2008 as Ph. Eur. Prekallikrein activator in albumin Biological Reference Preparation batch 2 and batch 3.

    • 1 December 2008
      • Vol. 2008  (1) , 7-18

    Evaluation of two serological methods for potency testing of whole cell pertussis vaccines.

    by C Von Hunolstein, M J Gomez Miguel, C Pezzella, F Scopetti, M-E Behr-Gross, M Halder, S Hoffmann, L Levels, J Van Der Gun, C Hendriksen

    The European Pharmacopoeia (Ph. Eur.) and the World Health Organization (WHO) require the performance of extensive quality control testing including a potency test before a vaccine batch is released for human use. Whole cell pertussis (wP) vaccine potency is assessed by a mouse protection test (MPT) based on the Kendrick test. This test compares the vaccine dose necessary to protect 50% of mice against the effect of a lethal intracerebral dose of Bordetella pertussis and the dose of a suitable reference vaccine needed to give the same protection level. Due to the large variability in the results of this test and the severe distress which is inflicted on the many animals involved, its replacement by an alternative method is highly desirable. At the initiative of the European Directorate for the Quality of Medicines and HealthCare (EDQM) of the Council of Europe, in collaboration with the WHO and the In-vitro toxicology Unit/European Centre for the Validation of Alternative Methods (ECVAM) of the European Commission (EC) Joint Research Centre-Institute for Health and Consumer Protection (JRC-IHCP), wP vaccine specialists from all over the world were invited to present an overview of candidate alternatives at a symposium organised in Geneva (Switzerland) in March 2005. Although no alternative method was found suitable for immediate implementation of batch potency control, the Pertussis Serological Potency Test (PSPT), initially developed in mice and recently transferred to guinea pigs (gps), was identified as a model of interest. Using the PSPT in gps to test several components of combined vaccines such as Diphtheria-Tetanus-wP vaccines in the same animal series would allow further implementation of the European 3Rs policy to batch potency control, by additional method refinement and reduction of animal use. The present study evaluated 2 features of the serological response to wP vaccination: 1) the overall antibody response as measured by a "whole cell" ELISA (PSPT-wC-ELISA) which uses the B. pertussis 18323 challenge strain prescribed for the MPT to coat the assay plates and 2) the functional neutralising antibodies to pertussis toxin (PT, one of the main virulence factors of B. pertussis), as measured by the Chinese Hamster Ovary (CHO) cell assay. The results showed that 1) the gp model can be used for wP vaccine potency testing; 2) despite good repeatability and precision, the CHO cell assay did not generate results comparable to the MPT. Moreover, the CHO cell assay showed significant differences in the ability of wP vaccines to induce neutralising anti-PT antibodies, which did not correlate to the overall antibody response evaluated by PSPT-wC-ELISA; 3) comparable potencies were obtained in the MPT and the PSPT-wC-ELISA. This study, supported by the previous ones correlating the PSPT-wC-ELISA in mice with the MPT, confirms that PSPT-wC-ELISA in gps is a promising approach for batch release potency testing of wP vaccines for which consistency in production has already been demonstrated by the MPT. However, a large scale validation study is required prior to the adoption of PSPT-wC-ELISA as a compendial reference method for wP vaccines batch release control.