Farzad Razavi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Farzad Razavi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Behrooz Taheri
Faculty of Electrical, Biomedical and Mechatronics Engineering, Qazvin Branch, Islamic Azad University, Qazvin, Iran
2 shared publicationsMohammad Parpaei
Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran
2 shared publicationsSirus Salehimehr
Young Researchers and Elite Club, Qazvin Branch, Islamic Azad University, Qazvin, Iran
2 shared publications- Ali Akbar Nazari
Department of Electrical Engineering, Qazvin Branch, Islamic Azad University, Qazvin 341851416, Iran
1 shared publication - Behrooz Taheri
Department of Electrical Engineering Qazvin Branch Islamic Azad University Qazvin Iran
1 shared publication - Behrooz Taheri
Department of Electrical Engineering, Qazvin Branch, Islamic Azad University, Qazvin 341851416, Iran
1 shared publication
Latest Publications
- 14 November 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (5) , 5807-5822
Presenting an innovative single-setting adaptive protection method for AC microgrid with wind turbine
- 14 November 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (5) , 5807-5822
Presenting an innovative single-setting adaptive protection method for AC microgrid with wind turbine
- Open Access
- 27 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 13953
Proposing a New Approach to Generate the Differential Trajectory of the Differential Relays Using COMTRADE Files
The differential relay is subject to transient events such as inrush current, which may affect its correct operation. Therefore, evaluating the reliable and accurate operation of differential relays is important, which is only possible by mapping the relay’s differential trajectory on its setting curve. However, except for the SIGRA software, creating a differential trajectory only for Siemens relays, there is a gap in developing a method to extract this trajectory for other commercial differential relays. Hence, in this paper, a new method for generating the differential trajectory of the differential relay from their six input currents and mapping it on the relay setting curve is presented. The proposed method uses the differential relay COMTRADE files to access the relay input currents during an incident. The currents recorded in the COMTRADE files belong to the secondary sides of the current transformers (CTs). Accordingly, the impacts of the current transformers’ connections and the protected transformer’s connection type should be considered in the proposed study. The ability of the proposed method to generate the differential trajectory for different incidents that occurred on the power transformers is evaluated using simulation studies and also according to the experimental tests. The results illustrate the efficiency of the proposed method in generating the differential trajectory from the COMTRADE files. In addition, comparing the results of the proposed method with the results created in SIGRA software shows the higher accuracy of the proposed method in producing the differential trajectory of the differential relay.
- 27 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 13953
Open AccessProposing a New Approach to Generate the Differential Trajectory of the Differential Relays Using COMTRADE Files
The differential relay is subject to transient events such as inrush current, which may affect its correct operation. Therefore, evaluating the reliable and accurate operation of differential relays is important, which is only possible by mapping the relay’s differential trajectory on its setting curve. However, except for the SIGRA software, creating a differential trajectory only for Siemens relays, there is a gap in developing a method to extract this trajectory for other commercial differential relays. Hence, in this paper, a new method for generating the differential trajectory of the differential relay from their six input currents and mapping it on the relay setting curve is presented. The proposed method uses the differential relay COMTRADE files to access the relay input currents during an incident. The currents recorded in the COMTRADE files belong to the secondary sides of the current transformers (CTs). Accordingly, the impacts of the current transformers’ connections and the protected transformer’s connection type should be considered in the proposed study. The ability of the proposed method to generate the differential trajectory for different incidents that occurred on the power transformers is evaluated using simulation studies and also according to the experimental tests. The results illustrate the efficiency of the proposed method in generating the differential trajectory from the COMTRADE files. In addition, comparing the results of the proposed method with the results created in SIGRA software shows the higher accuracy of the proposed method in producing the differential trajectory of the differential relay.
- 2 August 2020
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 68 (6) , 4516-4528
Symmetrical Fault Detection During Power Swing Using Mean Value of Sampled Data from the Current Signal
One of the most challenging events for distance relays is a transient phenomenon known as power swing, which can have damaging results to the system. The occurrence of power swing can cause the impedance trajectory to enter protective zones of distance relays that may lead them to the wrong operation. Malfunction of distance relays can create instability in power systems, and a large blackout may occur in these networks. The purpose of this paper is to introduce a new method based on using the mean value of sampled data from the current signal to recognize power swing from simultaneous faults. This method has been tested using DIgSILENT and MATLAB software on a two-bus network with parallel lines. The obtained results demonstrate that the proposed scheme is capable of detecting various types of power swings, including both unstable and stable power swing. The presented method in this paper also has an accurate operation to detect simultaneous symmetric faults. Besides, this method is planned for a protection system with a central controller using the IEC-61850 standard.
- 2 August 2020
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 68 (6) , 4516-4528
Symmetrical Fault Detection During Power Swing Using Mean Value of Sampled Data from the Current Signal
One of the most challenging events for distance relays is a transient phenomenon known as power swing, which can have damaging results to the system. The occurrence of power swing can cause the impedance trajectory to enter protective zones of distance relays that may lead them to the wrong operation. Malfunction of distance relays can create instability in power systems, and a large blackout may occur in these networks. The purpose of this paper is to introduce a new method based on using the mean value of sampled data from the current signal to recognize power swing from simultaneous faults. This method has been tested using DIgSILENT and MATLAB software on a two-bus network with parallel lines. The obtained results demonstrate that the proposed scheme is capable of detecting various types of power swings, including both unstable and stable power swing. The presented method in this paper also has an accurate operation to detect simultaneous symmetric faults. Besides, this method is planned for a protection system with a central controller using the IEC-61850 standard.
- 20 December 2019
- Published by Springer Nature in Electrical Engineering
- Vol. 102 (2) , 663-681
A new power swing detection method based on chaos theory
- 20 December 2019
- Published by Springer Nature in Electrical Engineering
- Vol. 102 (2) , 663-681
A new power swing detection method based on chaos theory
- 4 January 2019
- Published by Springer Nature in Energy Systems
- Vol. 11 (2) , 491-514
Detection of power swing and fault occurring simultaneously with power swing using instantaneous frequency
- 4 January 2019
- Published by Springer Nature in Energy Systems
- Vol. 11 (2) , 491-514
Detection of power swing and fault occurring simultaneously with power swing using instantaneous frequency