John Gueulette
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John Gueulette has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
A Wambersie
Cliniques universitaires Saint-Luc, université catholique de Louvain, av Hippocrate, 10, 1200 Bruxelles, Belgique
8 shared publications- Vincent Grégoire
Universityersité Catholique de Louvain, Brussels, Brussels, BE
7 shared publications M Beauduin
Radio- and Neutrontherapy Department, Université Catholique de Louvain, Brussels, Belgium
4 shared publicationsB M De Coster
3 shared publicationsS Vynckier
3 shared publicationsA. Wambersie
2 shared publications
Latest Publications
- 1 December 2010
- Published by Elsevier in Radiation Measurements
- Vol. 45 (10) , 1414-1416
Fast neutrons: Inexpensive and reliable tool to investigate high-LET particle radiobiology
- 1 December 2010
- Published by Elsevier in Radiation Measurements
- Vol. 45 (10) , 1414-1416
Fast neutrons: Inexpensive and reliable tool to investigate high-LET particle radiobiology
- 1 December 2005
- Published by Radiation Research Society in Radiation Research
- Vol. 164 (6) , 805-809
RBE of the MIT Epithermal Neutron Beam for Crypt Cell Regeneration in Mice
Gueulette, J., Binns, P. J., De Coster, B. M., Lu, X-Q., Roberts, S. A. and Riley, K. J. RBE of the MIT Epithermal Neutron Beam for Crypt Cell Regeneration in Mice. Radiat. Res. 164, 805–809 (2005).The RBE of the new MIT fission converter epithermal neutron capture therapy (NCT) beam has been determined using intestinal crypt regeneration in mice as the reference biological system. Female BALB/c mice were positioned separately at depths of 2.5 and 9.7 cm in a Lucite phantom where the measured total absorbed dose rates were 0.45 and 0.17 Gy/ min, respectively, and irradiated to the whole body with no boron present. The γ-ray (low-LET) contributions to the total absorbed dose (low- high-LET dose components) were 77% (2.5 cm) and 90% (9.7 cm), respectively. Control irradiations were performed with the same batch of animals using 6 MV photons at a dose rate of 0.83 Gy/min as the reference radiation. The data were consistent with there being a single RBE for each NCT beam relative to the reference 6 MV photon beam. Fitting the data according to the LQ model, the RBEs of the NCT beams were estimated as 1.50 ± 0.04 and 1.03 ± 0.03 at depths of 2.5 and 9.7 cm, respectively. An alternative parameterization of the LQ model considering the proportion of the high- and low-LET dose components yielded RBE values at a survival level corresponding to 20 crypts (16.7%) of 5.2 ± 0.6 and 4.0 ± 0.7 for the high-LET component (neutrons) at 2.5 and 9.7 cm, respectively. The two estimates are significantly different (P = 0.016). There was also some evidence to suggest that the shapes of the curves do differ somewhat for the different radiation sources. These discrepancies could be ascribed to differences in the mechanism of action, to dose-rate effects, or, more likely, to differential sampling of a more complex dose–response relationship.
- 1 December 2005
- Published by Radiation Research Society in Radiation Research
- Vol. 164 (6) , 805-809
RBE of the MIT Epithermal Neutron Beam for Crypt Cell Regeneration in Mice
Gueulette, J., Binns, P. J., De Coster, B. M., Lu, X-Q., Roberts, S. A. and Riley, K. J. RBE of the MIT Epithermal Neutron Beam for Crypt Cell Regeneration in Mice. Radiat. Res. 164, 805–809 (2005).The RBE of the new MIT fission converter epithermal neutron capture therapy (NCT) beam has been determined using intestinal crypt regeneration in mice as the reference biological system. Female BALB/c mice were positioned separately at depths of 2.5 and 9.7 cm in a Lucite phantom where the measured total absorbed dose rates were 0.45 and 0.17 Gy/ min, respectively, and irradiated to the whole body with no boron present. The γ-ray (low-LET) contributions to the total absorbed dose (low- high-LET dose components) were 77% (2.5 cm) and 90% (9.7 cm), respectively. Control irradiations were performed with the same batch of animals using 6 MV photons at a dose rate of 0.83 Gy/min as the reference radiation. The data were consistent with there being a single RBE for each NCT beam relative to the reference 6 MV photon beam. Fitting the data according to the LQ model, the RBEs of the NCT beams were estimated as 1.50 ± 0.04 and 1.03 ± 0.03 at depths of 2.5 and 9.7 cm, respectively. An alternative parameterization of the LQ model considering the proportion of the high- and low-LET dose components yielded RBE values at a survival level corresponding to 20 crypts (16.7%) of 5.2 ± 0.6 and 4.0 ± 0.7 for the high-LET component (neutrons) at 2.5 and 9.7 cm, respectively. The two estimates are significantly different (P = 0.016). There was also some evidence to suggest that the shapes of the curves do differ somewhat for the different radiation sources. These discrepancies could be ascribed to differences in the mechanism of action, to dose-rate effects, or, more likely, to differential sampling of a more complex dose–response relationship.
- 1 December 2004
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 73, S148-S154
Intestinal crypt regeneration in mice : a biological system for quality assurance in non-conventional radiation therapy
- 1 December 2004
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 73, S148-S154
Intestinal crypt regeneration in mice : a biological system for quality assurance in non-conventional radiation therapy
- 1 July 2000
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 47 (4) , 1051-1058
Proton relative biological effectiveness (RBE) for survival in mice after thoracic irradiation with fractionated doses
- 1 July 2000
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 47 (4) , 1051-1058
Proton relative biological effectiveness (RBE) for survival in mice after thoracic irradiation with fractionated doses
- Open Access
- 1 January 1996
- Published by EDP Sciences in Journal de Chimie Physique et de Physico-Chimie Biologique
- Vol. 93, 244-252
Thérapie anticancéreuse par rayonnements à TEL élevé
- 1 January 1996
- Published by EDP Sciences in Journal de Chimie Physique et de Physico-Chimie Biologique
- Vol. 93, 244-252
Open AccessThérapie anticancéreuse par rayonnements à TEL élevé
- 1 January 1993
- Published by JSTOR in Radiation Research
- Vol. 133 (1) , 27-32
Radiobiological Intercomparison of p(45)+Be and p(65)+Be Neutron Beams for Lung Tolerance in Mice after Single and Fractionated Irradiation
The lung tolerance in mice after single and fractionated irradiations with p(45)+Be and p(65)+Be neutrons produced at the isochronous cyclotron "CYCLONE" of Louvain-la-Neuve (Belgium) was studied. Cobalt-60 gamma rays were used for control irradiations. The end point was the dose which was lethal to 50% of the mice by 180 days (LD50/180). On a log-log plot, the slope (+/- SE) of the relationship between total isoeffect dose and fraction number decreases from 0.34 +/- 0.01 for gamma rays to 0.19 +/- 0.01 for p(65)+Be and 0.12 +/- 0.01 for p(45)+Be neutrons. The data have been analyzed using the linear-quadratic (LQ) model. The alpha/beta ratio (+95% confidence interval) increases from 5.3 (4.3-6.4) for gamma rays to 20.7 (16.7-24.9) for p(65)+Be and 37.9 (25.8-65.8) for p(45)+Be. The RBEs of neutrons relative to gamma rays were estimated from the LQ parameters, to 1.15 and 1.19 for a dose of 14 Gy gamma rays and 2.02 and 2.47 for a dose of 2 Gy gamma rays for p(65)+Be and p(45)+Be neutrons, respectively. The neutron RBE of the p(45)+Be relative to the p(65)+Be calculated from the ratio of their respective RBEs relative to gamma rays reaches 1.03 and 1.23 for doses of 14 and 2 Gy gamma-ray equivalent, respectively. These data are compared with other published data on lung tolerance after irradiation with lower-energy neutrons and with data obtained previously in our laboratory on mouse jejunum and Vicia faba.
- 1 January 1993
- Published by JSTOR in Radiation Research
- Vol. 133 (1) , 27-32
Radiobiological Intercomparison of p(45)+Be and p(65)+Be Neutron Beams for Lung Tolerance in Mice after Single and Fractionated Irradiation
The lung tolerance in mice after single and fractionated irradiations with p(45)+Be and p(65)+Be neutrons produced at the isochronous cyclotron "CYCLONE" of Louvain-la-Neuve (Belgium) was studied. Cobalt-60 gamma rays were used for control irradiations. The end point was the dose which was lethal to 50% of the mice by 180 days (LD50/180). On a log-log plot, the slope (+/- SE) of the relationship between total isoeffect dose and fraction number decreases from 0.34 +/- 0.01 for gamma rays to 0.19 +/- 0.01 for p(65)+Be and 0.12 +/- 0.01 for p(45)+Be neutrons. The data have been analyzed using the linear-quadratic (LQ) model. The alpha/beta ratio (+95% confidence interval) increases from 5.3 (4.3-6.4) for gamma rays to 20.7 (16.7-24.9) for p(65)+Be and 37.9 (25.8-65.8) for p(45)+Be. The RBEs of neutrons relative to gamma rays were estimated from the LQ parameters, to 1.15 and 1.19 for a dose of 14 Gy gamma rays and 2.02 and 2.47 for a dose of 2 Gy gamma rays for p(65)+Be and p(45)+Be neutrons, respectively. The neutron RBE of the p(45)+Be relative to the p(65)+Be calculated from the ratio of their respective RBEs relative to gamma rays reaches 1.03 and 1.23 for doses of 14 and 2 Gy gamma-ray equivalent, respectively. These data are compared with other published data on lung tolerance after irradiation with lower-energy neutrons and with data obtained previously in our laboratory on mouse jejunum and Vicia faba.
- 1 January 1990
- Vol. 166 (1) , 18-21
Radiobiological comparison of fast neutron beams used in therapy. Survey of the published data.
- 1 January 1990
- Vol. 166 (1) , 18-21
Radiobiological comparison of fast neutron beams used in therapy. Survey of the published data.
- 1 April 1989
- Vol. 165 (4) , 263-7
Radiobiological intercomparisons of fast neutron beams used in therapy.
A research program was performed at Louvain-la-Neuve to systematically determine the RBE of fast neutrons for the growth inhibition in Vicia faba bean roots and for the regeneration of the intestinal crypts in mice. The following neutron beams were compared p(75) + Be, p(65) + Be, p(45) + Be, p(34) + Be, d(20) + Be, and d(50) + Be. The RBE-variation as a function of neutron energy is larger for the Vicia faba system than for the regeneration of the intestinal crypt cells. This can be related to the inherent differency of the biological systems, but also to the different dose ranges involved (0.33 to 0.56 Gy and 7.66 to 8.56 Gy, respectively). In the high energy range explored, defined by the reactions p(75) + Be to p(34) + Be RBE varies only between 0.92 and 1.28 for Vicia faba and 0.96 and 1.12 for crypt cells normalized to the p(65) + Be beam. By contrast the RBE at lower energy beams (d(20) + Be and d(14.5) + Be) reaches values between 1.5 and 1.6 Finally fractionation has shown to be likely more important at the high energy beams.
- 1 April 1989
- Vol. 165 (4) , 263-7
Radiobiological intercomparisons of fast neutron beams used in therapy.
A research program was performed at Louvain-la-Neuve to systematically determine the RBE of fast neutrons for the growth inhibition in Vicia faba bean roots and for the regeneration of the intestinal crypts in mice. The following neutron beams were compared p(75) + Be, p(65) + Be, p(45) + Be, p(34) + Be, d(20) + Be, and d(50) + Be. The RBE-variation as a function of neutron energy is larger for the Vicia faba system than for the regeneration of the intestinal crypt cells. This can be related to the inherent differency of the biological systems, but also to the different dose ranges involved (0.33 to 0.56 Gy and 7.66 to 8.56 Gy, respectively). In the high energy range explored, defined by the reactions p(75) + Be to p(34) + Be RBE varies only between 0.92 and 1.28 for Vicia faba and 0.96 and 1.12 for crypt cells normalized to the p(65) + Be beam. By contrast the RBE at lower energy beams (d(20) + Be and d(14.5) + Be) reaches values between 1.5 and 1.6 Finally fractionation has shown to be likely more important at the high energy beams.
- 1 April 1989
- Vol. 165 (4) , 272-5
Early repair kinetics of intestine and lung in mice, after fast neutron and photon irradiation.
Early repair (Elkind repair) kinetics of an early and a late responding tissue after gamma and d(50) + Be neutron irradiation were compared in mice. LD50 at five days after abdominal irradiation and LD50 at 180 days after thoracic irradiation were chosen as biological endpoints to study intestinal and lung tolerance, respectively. Elkind repair is assessed from the additional dose Dr to reach LD50 when a single dose Ds is split into two equal fractions Di separated by time intervals "i" ranging from 0 to 24 hours (Dr = 2Di-Ds). Dr is greater for lung than for intestine after both gamma and neutron irradiations. Our data are consistent with an exponential early repair with an half-life (T 1/2) of 0.5 h for intestine and 1.5 to 2 h for lung.
- 1 April 1989
- Vol. 165 (4) , 272-5
Early repair kinetics of intestine and lung in mice, after fast neutron and photon irradiation.
Early repair (Elkind repair) kinetics of an early and a late responding tissue after gamma and d(50) + Be neutron irradiation were compared in mice. LD50 at five days after abdominal irradiation and LD50 at 180 days after thoracic irradiation were chosen as biological endpoints to study intestinal and lung tolerance, respectively. Elkind repair is assessed from the additional dose Dr to reach LD50 when a single dose Ds is split into two equal fractions Di separated by time intervals "i" ranging from 0 to 24 hours (Dr = 2Di-Ds). Dr is greater for lung than for intestine after both gamma and neutron irradiations. Our data are consistent with an exponential early repair with an half-life (T 1/2) of 0.5 h for intestine and 1.5 to 2 h for lung.