VBValentino Bettinardi

Valentino Bettinardi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Valentino Bettinardi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Physical Performance of the new hybrid PET/CT Discovery-690

    by V. Bettinardi, L. Presotto, E. Rapisarda, M. Picchio, L. Gianolli, M. C. Gilardi

    The aim of this work was the assessment of the physical performance of the new hybrid PET∕CT system: Discovery-690. The Discovery-690 combines a lutetium-yttrium-orthosilicate (LYSO) block detector designed PET tomograph with a 64-slice CT scanner. The system is further characterized by a dedicated powerful computing platform implementing fully 3D-PET iterative reconstruction algorithms. These algorithms can account for time of flight (TOF) information and∕or a 3D model of the PET point spread function (PSF). PET physical performance was measured following NEMA NU-2-2007 procedures. Furthermore, specific tests were used: (i) to measure the energy and timing resolution of the PET system and (ii) to evaluate image quality, by using phantoms representing different clinical conditions (e.g., brain and whole body). Data processing and reconstructions were performed as required by standard procedures. Further reconstructions were carried out to evaluate the performance of the new reconstruction algorithms. In particular, four algorithms were considered for the reconstruction of the PET data: (i) HD = standard configuration, without TOF and PSF, (ii) TOF = HD + TOF, (iii) PSF = HD + PSF, and (iv) TOFPSF = HD + TOF + PSF. The transverse (axial) spatial resolution values were 4.70 (4.74) mm and 5.06 (5.55) mm at 1 cm and 10 cm off axis, respectively. Sensitivity (average between 0 and 10 cm) was 7.5 cps∕kBq. The noise equivalent count rate (NECR) peak was 139.1 kcps at 29.0 kBq∕ml. The scatter fraction at the NECR peak was 37%. The correction accuracy for the dead time losses and random event counts had a maximum absolute error below the NECR peak of 2.09%. The average energy and timing resolution were 12.4% and 544.3 ps, respectively. PET image quality was evaluated with the NEMA IEC Body phantom by using four reconstruction algorithms (HD, TOF, PSF, and TOFPSF), as previously described. The hot contrast (after 3 iterations and for a lesion∕background activity ratio of 4:1) for the spheres of 10, 13, 17, and 22 mm was (HD) 29.8, 45.4, 55.4, and 68.1%; (TOF) 39.9, 53.5, 62.7, and 72.2%; (PSF) 28.3, 47.3, 60.4, and 71.8%; (TOFPSF) 43.8, 62.9, 70.6, and 76.4%. The cold contrast for the spheres of 28 and 37 mm was (HD) 62.4 and 65.2%; (TOF) 77.1 and 81.4%; (PSF) 62.0 and 65.2%; (TOFPSF) 77.3 and 81.6%. Similar hot and cold contrast trends were found during the analyses of other phantoms representing different clinical conditions (brain and whole body). Nevertheless, the authors observed a predominant role of either TOF or PSF, depending on the specific characteristics and dimensions of the phantoms. Discovery-690 shows very good PET physical performance for all the standard NEMA NU-2-2007 measurements. Furthermore, the new reconstruction algorithms available for PET data (TOF and PSF) allow further improvements of the D-690 image quality performance both qualitatively and quantitatively.


  • Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques

    by Valentino Bettinardi, Maria Picchio, Nadia Di Muzio, Luigi Gianolli, Maria Carla Gilardi, Cristina Messa


    • 30 April 2007
      • Vol. 51  (3) , 214-23

    Two-dimensional vs three-dimensional imaging in whole body oncologic PET/CT: a Discovery-STE phantom and patient study.

    by V Bettinardi, P Mancosu, M Danna, G Giovacchini, C Landoni, M Picchio, M C Gilardi, A Savi, Isabella Castiglioni, M Lecchi, et al.

    To evaluate the performance of the positron emission tomography (PET)/computed tomography (CT) Discovery-STE (D-STE) scanner for lesion detectability in two-dimensional (2D) and three-dimensional (3D) acquisition. A NEMA 2001 Image-Quality phantom with 11 lesions (7-37 mm in diameter) filled with a solution of 18F (lesion/background concentration ratio: 4.4) was studied. 2D and 3D PET scans were sequentially acquired (10 min each) in list mode (LM). Each scan was unlisted into 4, 3 and 2-min scans. Ten [18F]FDG PET oncological patient studies were also evaluated. Each patient underwent a 3D PET/CT whole body scan, followed by a 2D PET scan (4 min LM) and a 3D PET scan (4 min LM) over a single field of view. Both 2D and 3D scans were unlisted in 3 and 2-min scans. Data were evaluated quantitatively by calculating quality measurements and qualitatively by two physicians who judged lesion detectability compared to statistical variations in background activity. Quantitative and qualitative evaluations showed the superiority of 3D over 2D across all measures of quality. In particular, lesion detectability was better in 3D than in 2D at equal scan times and 3D acquisition provided images comparable in quality to 2D in approximately half the time. Interobserver variability was lower in evaluation of 3D scans and lesion shape and volume were better depicted. In oncological applications, the D-STE system demonstrated good performance in 2D and 3D acquisition, while 3D exhibited better image quality, data accuracy and consistency of lesion detectability, resulting in shorter scan times and higher patient throughput.