Luis Alexandre Maffei Sartini Paulillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luis Alexandre Maffei Sartini Paulillo has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Fonseca Lima
Dental Research Division Paulista University Sao Paulo Brazil
3 shared publications - Carlos Tadeu dos Santos Dias
Universidade Federal do Ceará
3 shared publications - Cintia Tereza Pimenta Araujo
Dentistry Department, School of Biological and Health Sciences, Federal University of the Jequitinhonha and Mucuri Valleys, Diamantina, Minas Gerais, Brazil
3 shared publications Lucia Trazzi Prieto
2 shared publicationsLúcia Trazzi Prieto
Department of Restorative Dentistry, Piracicaba School of Dentistry, State University of Campinas, SP, Brazil
2 shared publicationsCaio Cezar Randi Ferraz
1 shared publication
Latest Publications
- 7 July 2015
- Vol. 63 (4) , 22-6
Influence of irrigation protocols on the bond strength of fiber posts cemented with a self-adhesive luting agent 24 hours after endodontic treatment.
The aim of this in vitro study was to evaluate the influence of different irrigation protocols on the bond strength, at different root depths, of fiber posts cemented with a self-adhesive cement 24 hours after endodontic treatment. Fifty-six bovine incisor roots were endodontically prepared and separated into 7 groups (n = 8) according to irrigation protocols: group 1, sterile saline (control); group 2, chlorhexidine (CHX) gel 2% and saline; group 3, sodium hypochlorite (NaOCl) 5.25% and saline; group 4, CHX and saline (final irrigation with ethylenediaminetetraacetic acid [EDTA] 17%); group 5, NaOCl and saline (final irrigation with EDTA); group 6, CHX and saline (final irrigation with NaOCl and EDTA); and group 7, NaOCl (final irrigation with CHX and EDTA). No statistically significant difference was found among the groups. Within the limitations of this study, it can be concluded that the different irrigation protocols did not influence the bond strength of self-adhesive resin cement, which presented similar behaviors at the 3 root depths studied.
- 7 July 2015
- Vol. 63 (4) , 22-6
Influence of irrigation protocols on the bond strength of fiber posts cemented with a self-adhesive luting agent 24 hours after endodontic treatment.
The aim of this in vitro study was to evaluate the influence of different irrigation protocols on the bond strength, at different root depths, of fiber posts cemented with a self-adhesive cement 24 hours after endodontic treatment. Fifty-six bovine incisor roots were endodontically prepared and separated into 7 groups (n = 8) according to irrigation protocols: group 1, sterile saline (control); group 2, chlorhexidine (CHX) gel 2% and saline; group 3, sodium hypochlorite (NaOCl) 5.25% and saline; group 4, CHX and saline (final irrigation with ethylenediaminetetraacetic acid [EDTA] 17%); group 5, NaOCl and saline (final irrigation with EDTA); group 6, CHX and saline (final irrigation with NaOCl and EDTA); and group 7, NaOCl (final irrigation with CHX and EDTA). No statistically significant difference was found among the groups. Within the limitations of this study, it can be concluded that the different irrigation protocols did not influence the bond strength of self-adhesive resin cement, which presented similar behaviors at the 3 root depths studied.
- 7 May 2015
- Vol. 63 (3) , 31-7
Nanoleakage of fiber posts luted with different adhesive strategies and the effect of chlorhexidine on the interface of dentin and self-adhesive cements.
The aim of this in vitro study was to evaluate the nanoleakage of fiber posts luted using different adhesive strategies and to investigate the effect of 2% chlorhexidine (CHX) on nanoleakage at the resin-dentin interfaces of self-adhesive cements. The self-adhesive and etch-and-rinse adhesive groups tested demonstrated similar results with regard to nanoleakage. Pretreatment with CHX promoted an adequate seal at the resin-dentin interface for self-adhesive cements.
- 7 May 2015
- Vol. 63 (3) , 31-7
Nanoleakage of fiber posts luted with different adhesive strategies and the effect of chlorhexidine on the interface of dentin and self-adhesive cements.
The aim of this in vitro study was to evaluate the nanoleakage of fiber posts luted using different adhesive strategies and to investigate the effect of 2% chlorhexidine (CHX) on nanoleakage at the resin-dentin interfaces of self-adhesive cements. The self-adhesive and etch-and-rinse adhesive groups tested demonstrated similar results with regard to nanoleakage. Pretreatment with CHX promoted an adequate seal at the resin-dentin interface for self-adhesive cements.
- 10 January 2014
- Vol. 62 (1) , e28-31
Minimally invasive cosmetic dentistry: smile reconstruction using direct resin bonding.
Discrepancies in tooth size and shape can interfere with smile harmony. Composite resin can be used to improve the esthetics of the smile at a low cost while offering good clinical performance. This article presents an approach for restoring and correcting functional, anatomic, and esthetic discrepancies with minimal intervention, using composites and a direct adhesive technique. This conservative restorative procedure provided the patient with maximum personal esthetic satisfaction.
- 10 January 2014
- Vol. 62 (1) , e28-31
Minimally invasive cosmetic dentistry: smile reconstruction using direct resin bonding.
Discrepancies in tooth size and shape can interfere with smile harmony. Composite resin can be used to improve the esthetics of the smile at a low cost while offering good clinical performance. This article presents an approach for restoring and correcting functional, anatomic, and esthetic discrepancies with minimal intervention, using composites and a direct adhesive technique. This conservative restorative procedure provided the patient with maximum personal esthetic satisfaction.
- 3 July 2013
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 72 (2) , 113-119
Influence of photo-curing distance on bond strength and nanoleakage of self-etching adhesive bonds to enamel and dentin
Objectives. To assess the influence of light-curing unit tip distance on the microtensile bond strength (μTBS) and nanoleakage of self-etching adhesives to enamel and dentin. Materials and methods. Flat buccal surfaces were prepared on 198 bovine incisors. The teeth were randomly assigned into nine groups for μTBS (n = 8) and nanoleakage (n = 3) testing according to the adhesive system (Clearfil Protect Bond, Clearfil Tri-S Bond or One Up Bond F Plus) and distance from the light-curing tip (0, 3 or 6 mm). The bonded samples were tested in tension (0.5 mm/min) and nanoleakage was analyzed using SEM. Results. Clearfil Protect Bond exhibited the highest tensile strength on both enamel and dentin. Leakage was higher in samples exposed at a distance of 6 mm on enamel and 0 mm on dentin. One Up Bond F Plus experienced the greatest amount of nanoleakage on both substrates. Conclusions. Light-curing unit distance did not influence the μTBS of the adhesives, but nanoleakage increased on enamel samples when photoactivation occurred at a distance of 6 mm.
- 3 July 2013
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 72 (2) , 113-119
Influence of photo-curing distance on bond strength and nanoleakage of self-etching adhesive bonds to enamel and dentin
Objectives. To assess the influence of light-curing unit tip distance on the microtensile bond strength (μTBS) and nanoleakage of self-etching adhesives to enamel and dentin. Materials and methods. Flat buccal surfaces were prepared on 198 bovine incisors. The teeth were randomly assigned into nine groups for μTBS (n = 8) and nanoleakage (n = 3) testing according to the adhesive system (Clearfil Protect Bond, Clearfil Tri-S Bond or One Up Bond F Plus) and distance from the light-curing tip (0, 3 or 6 mm). The bonded samples were tested in tension (0.5 mm/min) and nanoleakage was analyzed using SEM. Results. Clearfil Protect Bond exhibited the highest tensile strength on both enamel and dentin. Leakage was higher in samples exposed at a distance of 6 mm on enamel and 0 mm on dentin. One Up Bond F Plus experienced the greatest amount of nanoleakage on both substrates. Conclusions. Light-curing unit distance did not influence the μTBS of the adhesives, but nanoleakage increased on enamel samples when photoactivation occurred at a distance of 6 mm.
- 16 December 2011
- Published by Wiley in Microscopy Research and Technique
- Vol. 75 (5) , 671-676
Nanoleakage evaluation of resin luting systems to dental enamel and leucite‐reinforced ceramic
Purpose: The aim of this study was to evaluate the nanoleakage patterns between dental enamel and reinforced leucite ceramic, bonded with resin luting systems and a flowable composite resin. Materials and Methods: Twelve crowns of bovine incisors were randomly divided into four groups (n = 3) according to the luting procedure: Excite/Variolink II, Clearfil SE Bond/Panavia F, Scotchbond Multi‐Purpose Plus/RelyX ARC, and Single Bond 2/Filtek Z350 Flow. To evaluate the nanoleakage patterns, IPS Empress Esthetic disks (5 mm Ø and 1.2‐mm thick) were bonded to enamel, and, after 24 h, the specimens were immersed in a 50% (w/v) solution of silver nitrate (24 h), fixed, dehydrated, and processed scanning electron microscopy (SEM). Results: None nanoleakage on interface of the groups that Single Bond 2 followed by the flowable composite were used. The highest percentage of nanoleakage was shown by the Excite/Variolink II protocol. Also, in all conditions tested, none silver nitrate uptake was observed between the leucite‐reinforced ceramic and the resin luting cement. Conclusions: The use of a two‐step etch‐and‐rinse adhesive with flowable composite was able to promote an adequate seal of the bond interface at the enamel. Moreover, the conventional dual‐cured resin cements associated with simplified and dual‐cured adhesives tested are also indicated to bond thin ceramics to enamel, since all presented low silver nitrate uptake. Microsc. Res. Tech., 2012.
- 16 December 2011
- Published by Wiley in Microscopy Research and Technique
- Vol. 75 (5) , 671-676
Nanoleakage evaluation of resin luting systems to dental enamel and leucite‐reinforced ceramic
Purpose: The aim of this study was to evaluate the nanoleakage patterns between dental enamel and reinforced leucite ceramic, bonded with resin luting systems and a flowable composite resin. Materials and Methods: Twelve crowns of bovine incisors were randomly divided into four groups (n = 3) according to the luting procedure: Excite/Variolink II, Clearfil SE Bond/Panavia F, Scotchbond Multi‐Purpose Plus/RelyX ARC, and Single Bond 2/Filtek Z350 Flow. To evaluate the nanoleakage patterns, IPS Empress Esthetic disks (5 mm Ø and 1.2‐mm thick) were bonded to enamel, and, after 24 h, the specimens were immersed in a 50% (w/v) solution of silver nitrate (24 h), fixed, dehydrated, and processed scanning electron microscopy (SEM). Results: None nanoleakage on interface of the groups that Single Bond 2 followed by the flowable composite were used. The highest percentage of nanoleakage was shown by the Excite/Variolink II protocol. Also, in all conditions tested, none silver nitrate uptake was observed between the leucite‐reinforced ceramic and the resin luting cement. Conclusions: The use of a two‐step etch‐and‐rinse adhesive with flowable composite was able to promote an adequate seal of the bond interface at the enamel. Moreover, the conventional dual‐cured resin cements associated with simplified and dual‐cured adhesives tested are also indicated to bond thin ceramics to enamel, since all presented low silver nitrate uptake. Microsc. Res. Tech., 2012.