    Exploring the Impact of T2-Weighted MRI Fat Saturation on Radiomics Stability for Brain Radionecrosis Prediction After Skull-Base Proton Therapy: A Pilot Study

    by Sithin Thulasi Seetha, Giulia Fontana, Sara Imparato, Sara Lillo, Lucia Pia Ciccone, Marina Francesca Achilli, Chiara Paganelli, Silvia Molinelli, Alberto Iannalfi, Guido Baroni, et al.

    Background/Objectives: In skull-base proton therapy, T2-weighted brain magnetic resonance (MR) imaging may be acquired with or without fat saturation (FS). The present study investigated the impact of this protocol variation on radiomics feature stability and brain radionecrosis (BRN) prediction. Methods: Paired T2-weighted FS and non-FS follow-up MR scans of proton-treated skull-base chordoma patients (n = 52) were used to assess feature stability. For BRN prediction (CTCAEv5 grade ≥ 1), baseline planning scans of chordoma and chondrosarcoma patients (n = 80) with mixed FS protocols were used. Following automated brain tissue segmentation, 1911 radiomics features were extracted from cerebrospinal fluid, gray, and/or white matter using PyRadiomics (v3.1.0). Feature stability was quantified using Lin’s concordance correlation coefficient (CCC). Several MR image- and feature-level processing configurations were explored, and the stability of combined gray and white matter features served as the reference for selecting the optimal configuration. Features were stratified based on CCC thresholds and were subjected to univariable feature selection using a Mann–Whitney U-test. Logistic regression was used for predictive modeling and its performance was measured using micro-averaged AUC within a repeated stratified cross-validation framework. Results: Radiomics features were highly sensitive to FS variations (median CCC range: 0.21–0.58). Combat harmonization without image-level processing was selected as the optimal configuration, under which 30% of features achieved CCC ≥ 0.70, and 10.7% demonstrated a CCC ≥ 0.85. Restricting modeling to a highly stable subset eliminated nearly 90% of the baseline features while significantly improving predictive performance (ΔAUC = 0.05, p < 0.001). Conclusions: A subset of radiomics features robust to FS variations was identified. Use of these stable features may mitigate the impact of protocol-induced variability in mixed-FS T2-weighted MR data while simultaneously improving BRN prediction performance. These findings are preliminary and should be interpreted cautiously, given the pilot nature of the study.


  • Open Access

    Towards a novel positioning system for a real-time prompt gamma imaging detector in hadrontherapy

    by L. Santini, K. Urban, A. Pella, G. Sellaro, G. Marchesi, A. Caracciolo, A. Forgione, M. Piroddi, C. Riboldi, G. Baroni, et al.

    Monitoring the prompt gamma rays emitted by the patient during irradiation enables potentially real-time verification of the treatment, particularly for detecting range shifts that may arise from patient motion and other sources of uncertainties. Keeping the detector inside the treatment room throughout irradiation would therefore provide valuable information without interrupting the clinical workflow. The integration of such a detector requires a dedicated positioning system. This work presents a novel detector positioning system designed for clinical use. The system consists of a trolley attached to the couch via the lockbar engagement and equipped with four legs that transfer the system's weight to the floor. Experiments were carried out at CNAO (Pavia). This center has a fixed beamline, then requiring the couch to move across multiple fields with a pantograph, the Patient Positioning System (PPS). To avoid interference with the PPS, the legs should be retracted during couch movements and lowered once the treatment position is reached. The elastic behavior of the couch under these conditions was experimentally characterized, confirming that leg retraction does not introduce measurable deformation. To further minimize treatment time, the detector is intended to remain inside the room even during the acquisition of diagnostic X-ray images. Interference analyses were therefore performed to determine the geometric conditions under which this is feasible, resulting in operational limits that allow the system to remain in place from patient setup through irradiation.

  • Open Access

    Radar Technologies in Motion-Adaptive Cancer Radiotherapy

    by Matteo Pepa, Giulia Sellaro, Ganesh Marchesi, Anita Caracciolo, Arianna Serra, Ester Orlandi, Guido Baroni, Andrea Pella

    Intra-fractional respiratory management represents one of the greatest challenges of modern cancer radiotherapy (RT), as significant breathing-induced lesion motion might affect target coverage and organs at risk (OARs) sparing, jeopardizing oncological and toxicity outcomes. The detrimental effects on dosage of uncompensated organ motion are exacerbated in RT with charged particles (e.g., protons and carbon ions), due to their higher ballistic selectivity. The simplest strategies to counteract this phenomenon are the use of larger treatment margins and reductions in or control of respiration (e.g., by means of compression belts, breath hold). Gating and tracking, which synchronize beam delivery with the respiratory signal, also represent widely adopted solutions. When tracking the tumor itself or surrogates, invasive procedures (e.g., marker implantation), an unnecessary imaging dose (e.g., in X-ray-based fluoroscopy), or expensive equipment (e.g., magnetic resonance imaging, MRI) is usually required. When chest and abdomen excursions are measured to infer internal tumor displacement, the additional devices needed to perform this task, such as pressure sensors or surface cameras, present inherent limitations that can impair the procedure itself. In this context, radars have intrigued the radiation oncology community, being inexpensive, non-invasive, contactless, and insensitive to obstacles. Even if real-world clinical implementation is still lagging behind, there is a growing body of research unraveling the potential of these devices in this field. The purpose of this narrative review is to provide an overview of the studies that have delved into the potential of radar-based technologies for motion-adaptive photon and particle RT applications.


  • Open Access

    Unsupervised Deep Learning for Synthetic CT Generation from CBCT Images for Proton and Carbon Ion Therapy for Paediatric Patients

    by Matteo Pepa, Siavash Taleghani, Giulia Sellaro, Alfredo Mirandola, Francesca Colombo, Sabina Vennarini, Mario Ciocca, Chiara Paganelli, Ester Orlandi, Guido Baroni, et al.

    Image-guided treatment adaptation is a game changer in oncological particle therapy (PT), especially for younger patients. The purpose of this study is to present a cycle generative adversarial network (CycleGAN)-based method for synthetic computed tomography (sCT) generation from cone beam CT (CBCT) towards adaptive PT (APT) of paediatric patients. Firstly, 44 CBCTs of 15 young pelvic patients were pre-processed to reduce ring artefacts and rigidly registered on same-day CT scans (i.e., verification CT scans, vCT scans) and then inputted to the CycleGAN network (employing either Res-Net and U-Net generators) to synthesise sCT. In particular, 36 and 8 volumes were used for training and testing, respectively. Image quality was evaluated qualitatively and quantitatively using the structural similarity index metric (SSIM) and the peak signal-to-noise ratio (PSNR) between registered CBCT (rCBCT) and vCT and between sCT and vCT to evaluate the improvements brought by CycleGAN. Despite limitations due to the sub-optimal input image quality and the small field of view (FOV), the quality of sCT was found to be overall satisfactory from a quantitative and qualitative perspective. Our findings indicate that CycleGAN is promising to produce sCT scans with acceptable CT-like image texture in paediatric settings, even when CBCT with narrow fields of view (FOV) are employed.


  • Open Access

    Personalized Setup Optimization Strategies to Improve Clinical Workflow in Image-Guided Pediatric Particle Therapy

    by Matteo Pepa, Andrea Pella, Giulia Sellaro, Federica Galante, Alfredo Mirandola, Angelica Ghirelli, Sabina Vennarini, Francesca Colombo, Sara Imparato, Alberto Iannalfi, et al.

    The purpose of this retrospective study was to simulate a daily pre-alignment strategy to mitigate systematic positioning errors in image-guided pediatric hadron therapy. All pediatric patients (32 patients, 853 fractions) treated from December 2021 and September 2022 at our Institution were retrospectively considered. For all fractions, daily correction vectors (CVs) resulting from image registration for patient positioning were retrieved in the form of txt files from the hospital database. For each fraction, an adjusted correction vector (V′) was then computed as the difference between the actual one (V) and the algebraic average of the previous ones, as to simulate patient pre-alignment before imaging. The Euclidean norm of each V′ was computed and normalized with respect to that of the corresponding V to derive N. Pre-correcting all the coordinate values led to a 46% average reduction (min 20%, max 60%) in CVs, considering the first 27 fractions (average value in this cohort of patients). Such a potential improvement (N < 1) was observed for the most patients’ fractions (781/853, 91.6%). For the remaining 72/853 cases (8.4%), a remarkable worsening (N > 2) involved only 7/853 (0.82%) fractions. The presented strategy shows promising outcomes in order to ameliorate pediatric patient setup before imaging. However, further investigations to identify patients most likely to benefit from this approach are warranted.

  • Open Access

    Setup Optimization in Ocular Proton Therapy at the National Centre for Oncological Hadrontherapy: Comparison of Two Approaches to Refine the Position of an Eye-Tracking Device

    by Giulia Sellaro, Andrea Pella, Matteo Pepa, Federica Galante, Mario Ciocca, Maria Rosaria Fiore, Agnieszka Chalaszczyk, Chiara Paganelli, Marco Rotondi, Alessandro Vai, et al.

    This study describes a method for setup optimization in patient simulation for ocular proton therapy (OPT) at the National Center for Oncological Hadrontherapy (CNAO) in Pavia, Italy, with the aim of minimizing the occupancy time of clinical areas and streamlining the actual procedure. Setup repeatability is ensured by patient-specific immobilization tools and relies on the patient’s ability to maintain a stable gaze direction according to the treatment plan. This is facilitated by aligning a light source (LED) on a patient-specific base along the prescribed gaze direction. At CNAO, a dedicated Eye-Tracking System (ETS) was designed to provide the patient with a visible source of light aligned to the desired gaze direction. The ETS position is defined prior to treatment planning, relying on optical-tracking guidance and comparing the position of passive markers fixed on the ETS chassis with patient-specific models prepared offline in accordance with the desired geometry. OPT at CNAO started in 2016 and may be considered as a consolidated clinical routine. However, all the preparation phases, including patient-specific ETS models and setup, still require long sessions in clinical areas such as the computed tomography (CT) and the treatment rooms, with a non-negligible impact on other activities. This study describes a novel approach for patient-specific definition of the ETS position and orientation, aiming at minimizing the time required for preparatory activities inside clinical areas. To minimize the occurrence of biases and to reproduce as much as possible a real end-to-end approach, we included in the analysis data of patients that received OPT in our facility. The study was performed in parallel, carrying out the alignment with the standard method currently used in the clinical workflow of CNAO and with the proposed method. Results are presented as 3D residuals and gaze deviations, comparing ETS alignment based on the new approach with respect to the clinical standard method. The preliminary results of this study are evidence of the capability of the procedure to align the ETS position, allowing performing of the procedure in a non-clinical dedicated room.


  • Open Access

    The Role of Carbon Ion Therapy in the Changing Oncology Landscape—A Narrative Review of the Literature and the Decade of Carbon Ion Experience at the Italian National Center for Oncological Hadrontherapy

    by Ester Orlandi, Amelia Barcellini, Barbara Vischioni, Maria Rosaria Fiore, Viviana Vitolo, Alberto Iannalfi, Maria Bonora, Agnieszka Chalaszczyk, Rossana Ingargiola, Giulia Riva, et al.

    Background: Currently, 13 Asian and European facilities deliver carbon ion radiotherapy (CIRT) for preclinical and clinical activity, and, to date, 55 clinical studies including CIRT for adult and paediatric solid neoplasms have been registered. The National Center for Oncological Hadrontherapy (CNAO) is the only Italian facility able to accelerate both protons and carbon ions for oncological treatment and research. Methods: To summarise and critically evaluate state-of-the-art knowledge on the application of carbon ion radiotherapy in oncological settings, the authors conducted a literature search till December 2022 in the following electronic databases: PubMed, Web of Science, MEDLINE, Google Scholar, and Cochrane. The results of 68 studies are reported using a narrative approach, highlighting CNAO’s clinical activity over the last 10 years of CIRT. Results: The ballistic and radiobiological hallmarks of CIRT make it an effective option in several rare, radioresistant, and difficult-to-treat tumours. CNAO has made a significant contribution to the advancement of knowledge on CIRT delivery in selected tumour types. Conclusions: After an initial ramp-up period, CNAO has progressively honed its clinical, technical, and dosimetric skills. Growing engagement with national and international networks and research groups for complex cancers has led to increasingly targeted patient selection for CIRT and lowered barriers to facility access.


  • Open Access

    Virtual 4DCT generated from 4DMRI in gated particle therapy: phantom validation and application to lung cancer patients

    by S Annunziata, M Rabe, A Vai, S Molinelli, A Nakas, G Meschini, A Pella, V Vitolo, A Barcellini, S Imparato, et al.

    Objective . Respiration negatively affects the outcome of a radiation therapy treatment, with potentially severe effects especially in particle therapy (PT). If compensation strategies are not applied, accuracy cannot be achieved. To support the clinical practice based on 4D computed tomography (CT), 4D magnetic resonance imaging (MRI) acquisitions can be exploited. The purpose of this study was to validate a method for virtual 4DCT generation from 4DMRI data for lung cancers on a porcine lung phantom, and to apply it to lung cancer patients in PT. Approach . Deformable image registration was used to register each respiratory phase of the 4DMRI to a reference phase. Then, a static 3DCT was registered to this reference MR image set, and the virtual 4DCT was generated by warping the registered CT according to previously obtained deformation fields. The method was validated on a physical phantom for which a ground truth 4DCT was available and tested on lung tumor patients, treated with gated PT at end-exhale, by comparing the virtual 4DCT with a re-evaluation 4DCT. The geometric and dosimetric evaluation was performed for both proton and carbon ion treatment plans. Main results . The phantom validation exhibited a geometrical accuracy within the maximum resolution of the MRI and mean dose deviations, with respect to the prescription dose, up to 3.2% for target D 95% , with a mean gamma pass rate of 98%. For patients, the virtual and re-evaluation 4DCTs showed good correspondence, with errors on target D 95% up to 2% within the gating window. For one patient, dose variations up to 10% at end-exhale were observed due to relevant inter-fraction anatomo-pathological changes that occurred between the planning and re-evaluation CTs. Significance . Results obtained on phantom data showed that the virtual 4DCT method was accurate, allowing its application on patient data for testing within a clinical scenario.


  • Open Access

    Feasibility of Proton Dosimetry Overriding Planning CT with Daily CBCT Elaborated through Generative Artificial Intelligence Tools

    by Matteo Rossi, Gabriele Belotti, Luca Mainardi, Guido Baroni, Pietro Cerveri

    Radiotherapy commonly utilizes CBCT for patient positioning and treatment monitoring. CBCT is deemed to be secure for patients, making it suitable for the delivery of fractional doses. However, limitations such as a narrow field of view, beam hardening, scattered radiation artifacts, and variability in pixel intensity hinder the direct use of raw CBCT for dose recalculation during treatment. To address this issue, reliable correction techniques are necessary to remove artifacts and remap pixel intensity into HU values. This study proposes a deep-learning framework for calibrating CBCT images acquired with narrow FOV systems and demonstrates its potential use in proton treatment planning updates. Cycle-consistent GAN processes raw CBCT to reduce scatter and remap HU. Monte Carlo simulation is used to generate CBCT scans, enabling the possibility to focus solely on the algorithm’s ability to reduce artifacts and cupping effects without considering intra-patient longitudinal variability and producing a fair comparison between planning CT and calibrated CBCT dosimetry. To showcase the viability of the approach using real-world data, experiments were also conducted using real CBCT. Tests were performed on a publicly available dataset of 40 patients who received ablative radiation therapy for pancreatic cancer. The simulated CBCT calibration led to a difference in proton dosimetry of less than 2%, compared to the planning CT. The potential toxicity effect on the organs at risk decreased from about 50% (uncalibrated) up the 2% (calibrated). The gamma pass rate at 3%/2mm produced an improvement of about 37% in replicating the prescribed dose before and after calibration (53.78% vs 90.26%). Real data also confirmed this with slightly inferior performances for the same criteria (65.36% vs 87.20%). These results may confirm that generative artificial intelligence brings the use of narrow FOV CBCT scans incrementally closer to clinical translation in proton therapy planning updates.

  • Open Access

    Synthetic CT in Carbon Ion Radiotherapy of the Abdominal Site

    by Giovanni Parrella, Alessandro Vai, Anestis Nakas, Noemi Garau, Giorgia Meschini, Francesca Camagni, Silvia Molinelli, Amelia Barcellini, Andrea Pella, Mario Ciocca, et al.

    The generation of synthetic CT for carbon ion radiotherapy (CIRT) applications is challenging, since high accuracy is required in treatment planning and delivery, especially in an anatomical site as complex as the abdomen. Thirty-nine abdominal MRI-CT volume pairs were collected and a three-channel cGAN (accounting for air, bones, soft tissues) was used to generate sCTs. The network was tested on five held-out MRI volumes for two scenarios: (i) a CT-based segmentation of the MRI channels, to assess the quality of sCTs and (ii) an MRI manual segmentation, to simulate an MRI-only treatment scenario. The sCTs were evaluated by means of similarity metrics (e.g., mean absolute error, MAE) and geometrical criteria (e.g., dice coefficient). Recalculated CIRT plans were evaluated through dose volume histogram, gamma analysis and range shift analysis. The CT-based test set presented optimal MAE on bones (86.03 ± 10.76 HU), soft tissues (55.39 ± 3.41 HU) and air (54.42 ± 11.48 HU). Higher values were obtained from the MRI-only test set (MAEBONE = 154.87 ± 22.90 HU). The global gamma pass rate reached 94.88 ± 4.9% with 3%/3 mm, while the range shift reached a median (IQR) of 0.98 (3.64) mm. The three-channel cGAN can generate acceptable abdominal sCTs and allow for CIRT dose recalculations comparable to the clinical plans.