Tadahiro Kawasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tadahiro Kawasaki has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Yoshizo Takai
6 shared publicationsRyuichi Shimizu
4 shared publicationsTakashi Ikuta
2 shared publicationsHidetoshi Utsuro
Department of Applied Physics, Faculty of Engineering, Osaka University Yamada-oka 2-1, Suita, Osaka 565-0871 Japan
1 shared publicationMasaki Taya
1 shared publicationYoshihide Kimura
1 shared publication
Latest Publications
- 24 September 2003
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 52 (4) , 375-381
Quantitative analysis of surface atom positions in a thick crystal as determined by a reconstructed exit wave.
Atomic structures of an Au (110) 2 x 1 reconstructed surface were analysed quantitatively using an exit wave reconstructed by the three-dimensional Fourier filtering method in high-resolution transmission electron microscopy. To reconstruct the exit wave in a relatively thick crystal, a practical criterion was proposed in the present analysis. In the 'pseudo-exit wave' obtained by the proposed criterion, relaxation of surface atoms was clearly visible in the top three layers. The atoms' displacement was measured to be about 5-20 pm. For quantitative analysis of the atom column positions, image contrast calculations were performed using a structural model of the Au (110) reconstructed surface. Calculations confirmed that the reconstructed pseudo-exit wave could represent the atom column positions directly with an accuracy of several pm, even for a relaxed surface, provided the sample thickness was <7 nm.
- 24 September 2003
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 52 (4) , 375-381
Quantitative analysis of surface atom positions in a thick crystal as determined by a reconstructed exit wave.
Atomic structures of an Au (110) 2 x 1 reconstructed surface were analysed quantitatively using an exit wave reconstructed by the three-dimensional Fourier filtering method in high-resolution transmission electron microscopy. To reconstruct the exit wave in a relatively thick crystal, a practical criterion was proposed in the present analysis. In the 'pseudo-exit wave' obtained by the proposed criterion, relaxation of surface atoms was clearly visible in the top three layers. The atoms' displacement was measured to be about 5-20 pm. For quantitative analysis of the atom column positions, image contrast calculations were performed using a structural model of the Au (110) reconstructed surface. Calculations confirmed that the reconstructed pseudo-exit wave could represent the atom column positions directly with an accuracy of several pm, even for a relaxed surface, provided the sample thickness was <7 nm.
- 14 January 2003
- Published by Wiley in Surface and Interface Analysis
- Vol. 35 (1) , 51-54
Phase reconstruction with simultaneous correction of spherical and astigmatic aberrations by three‐dimensional Fourier filtering method
A phase reconstruction technique in transmission electron microscopy (TEM), called the three‐dimensional Fourier filtering method (3D‐FFM), was extended to simultaneous correction of spherical aberration and twofold astigmatism. The effect of the aberration correction was confirmed experimentally for a wide spatial frequency range in the corrected through‐focus images of an amorphous thin film. As an application of this method, the surface structure of a gold nanoparticle was observed. The aberration‐free phase image clearly reconstructed the atomic missing‐row structure at the edge of the particle. Copyright © 2003 John Wiley & Sons, Ltd.
- 14 January 2003
- Published by Wiley in Surface and Interface Analysis
- Vol. 35 (1) , 51-54
Phase reconstruction with simultaneous correction of spherical and astigmatic aberrations by three‐dimensional Fourier filtering method
A phase reconstruction technique in transmission electron microscopy (TEM), called the three‐dimensional Fourier filtering method (3D‐FFM), was extended to simultaneous correction of spherical aberration and twofold astigmatism. The effect of the aberration correction was confirmed experimentally for a wide spatial frequency range in the corrected through‐focus images of an amorphous thin film. As an application of this method, the surface structure of a gold nanoparticle was observed. The aberration‐free phase image clearly reconstructed the atomic missing‐row structure at the edge of the particle. Copyright © 2003 John Wiley & Sons, Ltd.
- 1 December 2001
- Published by Elsevier in Ultramicroscopy
- Vol. 90 (1) , 47-59
Wave field restoration using three-dimensional Fourier filtering method
- 1 December 2001
- Published by Elsevier in Ultramicroscopy
- Vol. 90 (1) , 47-59
Wave field restoration using three-dimensional Fourier filtering method
- 1 September 2001
- Published by Oxford University Press (OUP) in QJM: An International Journal of Medicine
- Vol. 50 (5) , 405-412
Nano-area electron diffraction pattern reconstructed from three-dimensional Fourier spectrum.
A method to obtain a nano-area electron diffraction pattern in transmission electron microscopy (TEM) was proposed, based on three-dimensional (3D)) image formation theory. This method allows us to reconstruct an electron diffraction pattern from a 3D Fourier spectrum of high-resolution through-focus images. As a test case, an electron diffraction pattern from a tilted Si single crystal was reconstructed using the proposed method and compared with the conventional selected-area electron diffraction pattern. The intensity distribution of the reconstructed electron diffraction pattern was confirmed to be qualitatively equal to that of the selected-area electron diffraction pattern, though the degree of the equivalency between these patterns reduces at the high frequency region and the reproducibility of the intensity degrades when the number of images used in the image processing was decreased. By selecting areas in a reconstructed exit wave field, some electron diffraction patterns were obtained from the nano-areas without the influence of spherical aberration.
- 1 September 2001
- Published by Oxford University Press (OUP) in QJM: An International Journal of Medicine
- Vol. 50 (5) , 405-412
Nano-area electron diffraction pattern reconstructed from three-dimensional Fourier spectrum.
A method to obtain a nano-area electron diffraction pattern in transmission electron microscopy (TEM) was proposed, based on three-dimensional (3D)) image formation theory. This method allows us to reconstruct an electron diffraction pattern from a 3D Fourier spectrum of high-resolution through-focus images. As a test case, an electron diffraction pattern from a tilted Si single crystal was reconstructed using the proposed method and compared with the conventional selected-area electron diffraction pattern. The intensity distribution of the reconstructed electron diffraction pattern was confirmed to be qualitatively equal to that of the selected-area electron diffraction pattern, though the degree of the equivalency between these patterns reduces at the high frequency region and the reproducibility of the intensity degrades when the number of images used in the image processing was decreased. By selecting areas in a reconstructed exit wave field, some electron diffraction patterns were obtained from the nano-areas without the influence of spherical aberration.
- 1 September 2001
- Published by Oxford University Press (OUP) in QJM: An International Journal of Medicine
- Vol. 50 (5) , 413-416
Fourier analysis of HRTEM image deterioration caused by mechanical vibration.
Contrast deterioration of high‐resolution transmission electron microscope (HRTEM) images, that is caused by mechanical vibrations of the turbo molecular pump (TMP), was systematically and quantitatively investigated on the basis of Fourier analysis using plural images. It was demonstrated that TEM image contrast was considerably deteriorated by the resonance of mechanical vibration at specific rotational speeds of the TMP. By setting a TMP rotational speed from 48 000 rotations per minute (rpm) to 41 000 rpm, apart from the mechanical resonance frequencies of the present apparatus, the information limit of the observed image was improved from 6 nm−1 to 7 nm−1.
- 1 September 2001
- Published by Oxford University Press (OUP) in QJM: An International Journal of Medicine
- Vol. 50 (5) , 413-416
Fourier analysis of HRTEM image deterioration caused by mechanical vibration.
Contrast deterioration of high‐resolution transmission electron microscope (HRTEM) images, that is caused by mechanical vibrations of the turbo molecular pump (TMP), was systematically and quantitatively investigated on the basis of Fourier analysis using plural images. It was demonstrated that TEM image contrast was considerably deteriorated by the resonance of mechanical vibration at specific rotational speeds of the TMP. By setting a TMP rotational speed from 48 000 rotations per minute (rpm) to 41 000 rpm, apart from the mechanical resonance frequencies of the present apparatus, the information limit of the observed image was improved from 6 nm−1 to 7 nm−1.
- 1 January 1999
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 48 (1) , 35-37
Evaluation of image drift correction by three-dimensional Fourier analysis
The cross-correlation function has been applied to correct linear and random image drifts included in a through-focus series of images. A novel method based on three-dimensional Fourier analysis is proposed to evaluate how precisely the image drift correction is performed for the images. The linear and random drifts remaining after the correction are evaluated to be negligibly small by measuring the inclination and the sharpness appearing in the three-dimensional power spectrum.
- 1 January 1999
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 48 (1) , 35-37
Evaluation of image drift correction by three-dimensional Fourier analysis
The cross-correlation function has been applied to correct linear and random image drifts included in a through-focus series of images. A novel method based on three-dimensional Fourier analysis is proposed to evaluate how precisely the image drift correction is performed for the images. The linear and random drifts remaining after the correction are evaluated to be negligibly small by measuring the inclination and the sharpness appearing in the three-dimensional power spectrum.