AMAnupam K. Misra

Anupam K. Misra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anupam K. Misra has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Standoff real-time detection of floating and submerged objects in ocean water

    by Anupam K. Misra, Tayro E. Acosta‑Maeda, A. Zachary Trimble, Jie Zhou, Yan-Shan Liu, John N. Porter, Miles J. Egan

    Detecting and identifying floating or submerged objects in the ocean is very challenging with the current state of the art maritime-LIDAR technology. A LIDAR sensor has limitations in detecting objects that are near the surface of water due to strong glint produced by the reflection of the laser from the surface of water. In addition, whitecaps, foam, and air bubbles give strong scattering signals which make it difficult for a LIDAR sensor to detect and identify an object which is floating or is just below the ocean surface. We have developed a fluorescence sensor for standoff detection of objects that are either floating or submerged in shallow ocean waters. The fluorescence sensor is an active sensor that utilizes a nano-second Nd:YAG laser simultaneously emitting 355 and 532 nm laser pulses for illuminating a wide area for fluorescence excitation. The sensor provides live color images of floating and submerged objects in the ocean with each laser pulse excitation. The fluorescence sensor works in both daytime and nighttime operations and the presence/absence of direct sunlight; and surface reflections, air bubbles, and foam are not limiting factors for detection of objects in ocean water. The sensor is also immune to reflection or scattering of incident laser light from the ocean surface, overcoming challenges associated with LIDAR technology. The sensor can be integrated into a surface boat platform or an aerial platform e.g. drone, allowing it to provide real-time images of plastics and manmade objects (plastic bottles, clothes, fishing lines, ropes, oil spills, etc.) along with human bodies.


  • Open Access

    Applications of LIF to Document Natural Variability of Chlorophyll Content and Cu Uptake in Moss

    by Kelly Truax, Henrietta Dulai, Anupam Misra, Wendy Kuhne, Celia Smith, Ciara Bongolan-Aquino

    Chlorophyll has long been used as a natural indicator of plant health and photosynthetic efficiency. Laser-induced fluorescence (LIF) is an emerging technique for understanding broad spectrum organic processes and has more recently been used to monitor chlorophyll response in plants. Previous work has focused on developing a LIF technique for imaging moss mats to identify metal contamination with the current focus shifting toward application to moss fronds and aiding sample collection for chemical analysis. Two laser systems (CoCoBi a Nd:YGa pulsed laser system and Chl-SL with two blue continuous semiconductor diodes) were used to collect images of moss fronds exposed to increasing levels of Cu (1, 10, and 100 nmol/cm2) using a CMOS camera. The best methods for the preprocessing of images were conducted before the analysis of fluorescence signatures were compared to a control. The Chl-SL system performed better than the CoCoBi, with dynamic time warping (DTW) proving the most effective for image analysis. Manual thresholding to remove lower decimal code values improved the data distributions and proved whether using one or two fronds in an image was more advantageous. A higher DTW difference from the control correlated to lower chlorophyll a/b ratios and a higher metal content, indicating that LIF, with the aid of image processing, can be an effective technique for identifying Cu contamination shortly after an event.

  • Open Access

    Laser-Induced Fluorescence for Monitoring Environmental Contamination and Stress in the Moss Thuidium plicatile

    by Kelly Truax, Henrietta Dulai, Anupam Misra, Wendy Kuhne, Peter Fuleky, Celia Smith, Milton Garces

    The ability to detect, measure, and locate the source of contaminants, especially heavy metals and radionuclides, is of ongoing interest. A common tool for contaminant identification and bioremediation is vegetation that can accumulate and indicate recent and historic pollution. However, large-scale sampling can be costly and labor-intensive. Hence, non-invasive in-situ techniques such as laser-induced fluorescence (LIF) are becoming useful and effective ways to observe the health of plants through the excitation of organic molecules, e.g., chlorophyll. The technique presented utilizes images collected of LIF in moss to identify different metals and environmental stressors. Analysis through image processing of LIF response was key to identifying Cu, Zn, Pb, and a mixture of the metals at nmol/cm2 levels. Specifically, the RGB values from each image were used to create density histograms of each color channel’s relative pixel abundance at each decimal code value. These histograms were then used to compare color shifts linked to the successful identification of contaminated moss samples. Photoperiod and extraneous environmental stressors had minimal impact on the histogram color shift compared to metals and presented with a response that differentiated them from metal contamination.


  • Open Access

    Quantifying Moss Response to Metal Contaminant Exposure Using Laser-Induced Fluorescence

    by Kelly Truax, Henrietta Dulai, Anupam Misra, Wendy Kuhne, Peter Fuleky

    Tracing sources of contamination, including potentially toxic elements (PTEs), has historically been achieved through sampling and analysis of soil or biota, which are labor-intensive, costly, and destructive methods. Thus, availability of a non-destructive in situ remote sensing method for monitoring metals deposited in biota is of great interest. Laser-induced fluorescence (LIF) is an emerging spectroscopic and imaging technique that documents changes in molecular energy level in plants as a biological response to metal contamination. For a proof-of-concept study and preliminary experiment, moss was selected for experimentation due to its long history of use in tracing atmospheric deposition of PTEs. Consecutive treatments of copper chloride (CuCl2) were administered to three moss samples, simulating wet deposition every 48 h over 10 days until reaching cumulative Cu concentrations of 2.690 to 8.075 μmol/cm2. While these Cu amounts are above environmentally relevant concentrations, they allowed the best conditions for testing and fine tuning of the imaging and data processing protocols presented in this paper. Moss fluorescence was induced using both 532 nm green and 355 nm UV lasers. A CMOS camera captured images of the LIF response, and red–green–blue (RGB) decimal code values were extracted for each pixel in the images, and pixel densities of color channels from treated and untreated moss samples were compared. Results show a shift towards lower color decimal codes corresponding to increased Cu concentration. We developed and contrasted multiple quantitative analyses of color distributions and demonstrated that LIF shows great promise for remote sensing of Cu accumulation in moss at μmol/cm2 levels. Though currently, the method would be limited to highly toxic sites, it illustrates the possibility and provides a framework for development of higher-sensitivity methods to detect nmol/cm2 that are viable for urban contamination level monitoring.


  • Open Access

    Biofinder detects biological remains in Green River fish fossils from Eocene epoch at video speed

    by Anupam K. Misra, Sonia J. Rowley, Jie Zhou, Tayro E. Acosta-Maeda, Luis Dasilveira, Gregory Ravizza, Kenta Ohtaki, Tina M. Weatherby, A. Zachary Trimble, Patrick Boll, et al.

    The “Search for life”, which may be extinct or extant on other planetary bodies is one of the major goals of NASA planetary exploration missions. Finding such evidence of biological residue in a vast planetary landscape is an enormous challenge. We have developed a highly sensitive instrument, the “Compact Color Biofinder”, which can locate minute amounts of biological material in a large area at video speed from a standoff distance. Here we demonstrate the efficacy of the Biofinder to detect fossils that still possess strong bio-fluorescence signals from a collection of samples. Fluorescence images taken by the Biofinder instrument show that all Knightia spp. fish fossils analysed from the Green River formation (Eocene, 56.0–33.9 Mya) still contain considerable amounts of biological residues. The biofluorescence images support the fact that organic matter has been well preserved in the Green River formation, and thus, not diagenetically replaced (replaced by minerals) over such a significant timescale. We further corroborated results from the Biofinder fluorescence imagery through Raman and attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopies, scanning electron microscopy, energy dispersive X-ray spectroscopy (SEM–EDS), and fluorescence lifetime imaging microscopy (FLIM). Our findings confirm once more that biological residues can survive millions of years, and that using biofluorescence imaging effectively detects these trace residues in real time. We anticipate that fluorescence imaging will be critical in future NASA missions to detect organics and the existence of life on other planetary bodies.


  • Open Access

    Enhancement of the Anti-Stokes Fluorescence of Hollow Spherical Carbon Nitride Nanostructures by High Intensity Green Laser

    by Pavel V. Zinin, Tayro E. Acosta-Maeda, Anupam K. Misra, Shiv K. Sharma

    Fluorescence spectra of graphitic (g-C3N4) and spherical (s-C3N4) modifications of carbon nitride were measured as a function of green pulsed (6 ns-pulse) laser intensity. It was found that the intensity of the laser increases the maximum of the fluorescence shifts towards the anti-Stokes side of the fluorescence for s-C3N4 spherical nanoparticles. This phenomenon was not observed for g-C3N4 particles. The maximum of the anti-Stokes fluorescence in s-C3N4 nanoparticles was observed at 480 nm. The ratio of the intensity of the anti-Stokes peak (centered at 480 nm) to that of the Stokes peak (centered at 582 nm) was measured to be I484/582 = 6.4 × 10−3 at a low level of intensity (5 mW) of a green pulsed laser, whereas it rose to I484/582 = 2.27 with a high level of laser intensity (1500 mW).


  • Compact Color Biofinder (CoCoBi): Fast, Standoff, Sensitive Detection of Biomolecules and Polyaromatic Hydrocarbons for the Detection of Life

    by Anupam K. Misra, Tayro E. Acosta-Maeda, Jie Zhou, Miles J. Egan, Luis Dasilveira, John N. Porter, Sonia J. Rowley, A Zachary Trimble, Patrick Boll, Macey W. Sandford, et al.

    We have developed a compact instrument called the “COmpact COlor BIofinder”, or CoCoBi, for the standoff detection of biological materials and organics with polyaromatic hydrocarbons (PAHs) using a nondestructive approach in a wide area. The CoCoBi system uses a compact solid state, conductively cooled neodymium-doped yttrium aluminum garnet (Nd:YAG) nanosecond pulsed laser capable of simultaneously providing two excitation wavelengths, 355 and 532 nm, and a compact, sensitive-gated color complementary metal–oxide–semiconductor camera detector. The system is compact, portable, and determines the location of biological materials and organics with PAHs in an area 1590 cm 2 wide, from a target distance of 3 m through live video using fast fluorescence signals. The CoCoBi system is highly sensitive and capable of detecting a PAH concentration below 1 part per billion from a distance of 1 m. The color images provide the simultaneous detection of various objects in the target area using shades of color and morphological features. We demonstrate that this unique feature successfully detected the biological remains present in a 150-million-year-old fossil buried in a fluorescent clay matrix. The CoCoBi was also successfully field-tested in Hawaiian ocean water during daylight hours for the detection of natural biological materials present in the ocean. The wide-area and video-speed imaging capabilities of CoCoBi for biodetection may be highly useful in future NASA rover–lander life detection missions.


  • Underwater Time-Gated Standoff Raman Sensor for In Situ Chemical Sensing

    by Shiv K. Sharma, Bruce M. Howe, Anupam K. Misra, Mark R. Rognstad, John N. Porter, Tayro E. Acosta-Maeda, Miles J. Egan

    We describe the fabrication of an underwater time-gated standoff Raman sensor, consisting of a custom Raman spectrometer, custom scanner, and commercial diode-pumped pulsed 532 nm laser all located inside a pressure housing. The Raman sensor was tested in the laboratory with samples in air, a tank containing tap water and seawater, and in the coastal Hawaiian harbor. We demonstrate our new system by presenting standoff Raman spectra of some of the chemicals used in homemade explosive devices and improvised explosive devices, including sulfur, nitrates, chlorates, and perchlorates up to a distance of ∼6 m in seawater and tap water. Finally, the Raman spectra of these hazardous chemicals sealed inside plastic containers submersed in the Hawaiian Harbor water are also presented.


  • Detecting Minerals and Organics Relevant to Planetary Exploration Using a Compact Portable Remote Raman System at 122 Meters

    by Macey W. Sandford, Anupam K. Misra, Tayro Ernesto Acosta-Maeda, Shiv K. Sharma, John N. Porter, Miles J. Egan, M. Nurul Abedin

    Raman spectroscopy is a technique that can detect and characterize a range of molecular compounds such as water, water ice, water-bearing minerals, and organics of particular interest to planetary science. The detection and characterization of these molecular compounds, which are indications of habitability on planetary bodies, have become an important goal for planetary exploration missions spanning the solar system. Using a compact portable remote Raman system consisting of a 532 nm neodymium-doped yttrium aluminum garnet- (Nd:YAG-) pulsed laser, a 3-in. (7.62 cm) diameter mirror lens and a compact spectrograph with a miniature intensified charge coupled device (mini-ICCD), we were able to detect water (H 2 O), water ice (H 2 O-ice), CO 2 -ice, hydrous minerals, organics, nitrates, and an amino acid from a remote distance of 122 m in natural lighting conditions. To the best of our knowledge, this is the longest remote Raman detection using a compact system. The development of this uniquely compact portable remote Raman system is applicable to a range of solar system exploration missions including stationary landers for ocean worlds and lunar exploration, as they provide unambiguous detection of compounds indicative of life as well as resources necessary for further human exploration.


  • Open Access

    Remote Raman Detection of Chemicals from 1752 m During Afternoon Daylight

    by Anupam K. Misra, Tayro E. Acosta-Maeda, John N. Porter, Miles J. Egan, Macey W. Sandford, Tamra Oyama, Jie Zhou

    The detection and identification of materials from a distance is highly desirable for applications where accessibility is limited or there are safety concerns. Raman spectroscopy can be performed remotely and provides a very high level of confidence in detection of chemicals through vibrational modes. However, the remote Raman detection of chemicals is challenging because of the very weak nature of Raman signals. Using a remote Raman system, we performed fast remote detection of various solid and liquid chemicals from 1752 m during afternoon hours on a sunny day in Hawaii. Remote Raman systems with kilometer target range could be useful for chemical detection of volcanic gases, methane clathrate icebergs or fire ice, toxic gas clouds and toxic waste, explosives, and hazardous chemicals. With this successful test, we demonstrate the feasibility of developing future mid-size remote Raman systems suitable for long range chemical detection using helicopters and light airplanes.